UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION, In the Matter of Rochester Gas and Electric Corporation (R.

E. Ginna Nuclear Power Plant, Unit No.

1)

)

)

)

Docket No

)

)

50 244 APPLICATION FOR AMENDMENT TO OPERATING LICENSE Pursuant to Section 50.90 of the regulations of the U.S. Nuclear Regulatory Commission (the "Commission" ), Rochester Gas and Electric Corporation

("RG&E"), holder of Provisional Operating License No.

DPR-18, hereby requests that Sections 3.1.4 and 4.1 be revised in the Technical Specifications set forth in Appendix A to that license.

This request for a change in Technical Specifications is submitted in response to a letter dated September 24, 1981 from Mr. Dennis M. Crutchfield, Chief, Operating Reactors Branch No.

5 regarding reactor coolant system iodine activity The proposed technical specification change is set forth in Attachment A to this Application.

A safety evaluation is set forth in Attachment B.

This evaluation also demonstrates that the proposed change does not involve a significant change in the types or a significant increase in the amounts of effluents or any change in the authorized power level of the facility.

The proposed changes have been clearly identified as an NRC position in the NRC's Standard Technical Specifications for Westinghouse plants.

Therefore a fee of

$ 4,000 is required.

>>ooososo6

>>o>~>

'PDR.'ADQCK 05000244

.P

~ '":

PDR

f Fr I F

It tt

WHEREFORE, Applicant respectfully requests that Appendix A to Provisional Operating License No.

DPR-18 be amended in the form attached here to as Attachment A.

Rochester Gas and Electric Corporation By L. D. Whi e, Jr.

Executive Vice President Subscribed and sworn to before me on this l7 day of May, 1982.

GARY L.

EISS N

RY PUBLIC, State of N. Y. Monroe Co.

hfy Commfssfon Expfres Marsh 30, 19~

I i re g

~ -,~p )

t~s

.~ ',"3N 0 ~4

Attachment A

1 ~

Revise the Technical Specifications by replacing the following pages:

3.1-21,'.1-22, 3.1-23, 3.1-24, 4.1-8, 4.1-9, 4.1 2.

Add page 4.1-12.

Maximum Coolant Activit S ecifications:

Whenever the reactor is critical or the reactor coolant average temperature is greater than 500oF:

a.

The total specific activity of the reactor coolant shall not exceed 84/EpCi/gm, where E is the average beta and gamma energies per disintegration in Mev.

b.

The I-131 equivalent of the iodine activity in the reactor coolant shall not exceed 1.0ju:i/gm.

cd The I-131 equivalent of the iodine activity on the secondary side of a steam generator shall not exceed 0

~ l~Ci/gm.

If the limit of 3.1.4.l.a is exceeded, then be subcritical with reactor coolant average temperature less than 500 F within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

a ~

If the I-131 equivalent activity in the reactor coolant exceeds the limit of 3 '.4.l.b but is less than the allowable limit shown on Figure 3.1.4-1, operation may continue for up to 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> provided that the cumulative operating time under these circumstances does not exceed 800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br /> in any consecutive 12-month period.

If the I-131 equivalent activity in the reactor coolant exceeds the limit of 3.1.4 '.b for more than 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> in any consecutive 6-month period, 3 '-21 Amendment No ~ 8,rX8

then prepare and submit a Special Report to the Commission pursuant to Specification 6.9.2 within 30 days indicating the number of hours above this limit.

The reactor may be taken critical or reactor coolant average temperature may be increased above a 500 F with the I-131 equivalent activity greater than the limit of 3.1.4.l.b as long as the provisions of this paragraph are met.

b.

If the I-131 equivalent activity exceeds the limit of 3.1.4.1.b for more than 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> during one continuous time interval or exceeds the limit shown on Figure 3.1.4-1, be subcritical with c ~

reactor coolant average temperature less than 500oF within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

If the I-131 equivalent activity exceeds the limit of 3.1.4.l.b, then perform sampling and analysis as required by Table 4.1-4, item 4a, until the activity is reduced to less than the limit of 3.1

~ 4-1.b.

3-1.4.4 If the limit of 3.1.4.1."c is exceeded, then be at hot shutdown within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and in cold shutdown within the following 32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br />.

Basis:

The total activity limit for the primary system corresponds to operation with the plant design basis of 1% fuel defects.

Radiation shielding and the radioactive waste disposal systems 3 '-22 Amendment No. g5

were designed for operation with 1% defects The limit for secondary iodine activity is conservatively established with

,respect to the limits on primary system iodine activity and primary-to-secondary leakage (Specification 3.1.5.2).

If the activity should exceed the specified limits following a power transient the major concern would be whether additional fuel defects had developed bringing the total to above 1% defects.

Appropriate action to be taken to bring the activity within specification include one or more of the following:

gradual decrease in power to a lower base

power, increase in letdown flow rate, and venting of the volume control tank gases to the gas decay tanks.

The specified activity limits provide protection to the public against the potential release of reactor coolant activity to the atmosphere, as demonstrated by the analysis of a steam generator tube'upture accident. (3)

The 500 F temperature in the specification corresponds at saturation to 681 psia, which is below the set point of the secondary side relief valves.

Therefore, potential primary to secondary leakage at a temperature below 500 F can be contained by closing the steam line isolation valves.

References:

(1)

FSAR Table 9.2-5 (2)

FSAR Section 11.1.3 (3)

Letter dated September 24, 1981 from Dennis M. Crutchfield, USNRC, to John E. Maier, RGSE.

3.1-23

25O

~.

~

l~ f t

f I'1

~jl~LL Lf p

H M

O OH HO 200 150

'j UNACCEPl"ABlE OPERATION OOO IX0 O

C4 R

H CX 100 50 P-;CCf=PYAOLE OPCPiA f ION IH 0

,J..

20 30 40 50 60 70 80 90 100 PERCENT OF RATED THERMAL POWER Figure 3.1.4-1 I-131 Equivalent, Reactor Coolant Specific Activity Limit Versus Percent of Rated Thermal Power with the Reactor Coolant Specific Activity 1.0pCi/gram I-131 Equivalent 3.1-24

TABLE 4. 1-2

'MINIMUMFREQUENCIES POR EQUIPMENT AND SAMPLING TESTS FSAR Section Reference

1. Reactor Coolant Chemistry Samples Test Chloride and Fluoride Free@en~

3 times/week and at least every third day 5 times/week and at least. every second day except when below 250oF

2. Reactor Coolant Boron Boron concentration Weekly
3. Refueling Water Storage Tank Water Sample
4. Boric Acid Tank
5. Control Rods Boron concentration Boron concentration Rod drop times of all full length rods I

Weekly Twice/week After vessel head removal and at least once per 18 months (1)

6. Full Length Control Rod
7. Pressurizer Safety Valves
8. Main Steam Safety Valves
9. Containment Isolation Trip Mvement of at least 10 steps in any one direc-tion for any rod not fully inserted Set point Set point Functioning Monthly Each Refueling shutdawn Each Refueling shutdawn Each Refueling Shutdawn 10
10. Refueling System Interlocks Functioning Prior to Refueling Operations 9.4.5 ll. Service Wat,er System Functioning Each Refueling Shutdawn 9.5.5

, 12. Fire Protection Pump Auctioning and Pawer Supply Monthly 9.5.5 4.1-8 Amendment No. p,pp,yy,yp

FSAR Section Reference

14. Accumulator
15. Primary System

~ge Boron Concentration Evaluate Test

13. Spray Additive Tank NaOH Concent.

Fre~en~c monthly Bi-Monthly Daily

17. Spent Fuel Pit
18. Secondary Coolant Samples Boron Concentration Gross activity
16. Diesel Fuel Supply Fuel Inventory Daily monthly 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (2)(3) 8.2.3 9.5.5
19. Circulating Water Flood Protection Equignent Calibrate Each Refueling Shutdown Notes:

(1)

Also required for specifically affected individual rods following any maintenance on or modification to the control rod drive system which could affect the drop time of those specific rods.

(2)

Not required during a cold or refueling shutdown.

(3)

An isotopic analysis for I-131 equivalent activity is required at least monthly whenever the gross activity determination indicates iodine concentration greater than lOS of the allowable limit but only once per 6 rmnths whenever the gross activity determination indicates iodine concentration below 10% of the allmrhle limit.

4.1-9 Amendment No. Q, gg, /gal

INTENTIONALLYBLANK 4.1-10

Attachment B

The Technical Specification limits for reactor coolant system I-131 equivalent activity and for coolant activity sampling have been revised to be consistent with the NRC's Standard Technical Specifications for Westinghouse-designed plants.

The activity limits are.conservative with respect to the assumptions used in the NRC's analysis of a steam generator tube rupture event which was provided to RGGE by letter dated September 24, 1981.

TABLE 4.1-4

.i'v

'T i 0 REACTOR COOLANT SPECIFIC ACTIVITYSAMPLE TYPE OF MEASUREMENT AND ANALYSIS AND ANALYSIS PROGRAM SAMPLE AND ANALYSIS FREQUENCY MODES IN WHICH SAMPLE AND ANALYSIS REQUIRED Gross Activity Determination At least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (beta-gamma)

(1)

Above cold shutdown 2 ~

3 Isotopic Analysis for Dose Equivalent I-131 Concentra-tion Radiochemical for E Determination (2)

Isotopic Analysis for Iodine Including I-131, I-133, and I-135 1 per 14 days 1 per 6 months (3) a)

Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, whenever the I-131 equivalent activity exceeds the limit of 3.1

~ 4.l.b Above 5t reactor power Above 5% reactor power As required by Specificati'on 3.1.4.3.c*

b)

One sample between 2 and 6

hours following a reactor power change exceeding 15 per-cent within a 1-hour period Hot shutdown or above (1)

A gross radioactivity analysis shall consist of the quantitative measurement of the total radio-activity of the primary coolant in units~i/gm.

The total primary coolant activity shall be the sum of the degassed beta-gamma activity and the total of all identified gaseous activit'5 minutes after the primary system is sampled.

(2)

A radiochemical analysis shall consist of the quantitative measurement of the activity for each radionuclide which is identified in the primary coolant 15 minutes after the primary system is sampled.

The activities for the individual isotopes shall be used in the determination of E.

(3)

Sample to be taken after a minimum of 2 EFPD and 20 days of power operation have elapsed since reactor was last subcritical for 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or longer.

  • Except at refueling shutdown, sampling shall be continued until the activity of the reactor coolant system is restored to within its limits.

0 e