ATTACHMENT 2 QUALITY ASSURANCE MANUAL SECT. NO.

EFFECTIVE DATE:

REV.

PAGE 1

8 ROCHESTER GAS

& ELECTRIC CORPORATION GXNNA STATION August 1, 1980 SIGNATURE PREPARED GYI DATE TITLE:

APPENDIX A QUALITY AND SAFETY RELATED LISTXNG AND D XAGRAMS REVIEWED GY APPROVED SYI 7/2/

get

1. 0 2.0 Introduction Diagrams and a listing which may be used for guidance in determining safety related structures, systems and components are contained in this appendix.

The information is based on the list contained in Section 1.2.1 of the Final Facility Description and Safety Analysis Report.

Activities affecting the quality of safety related structures, systems and components are controlled to an extent consistent with their importance to safety.

The diagrams are color coded to represent the three quality groups which correspond with the guide-lines of Regulatory Guide 1.26.

Structures S stems and Com onents Listin 2.1 The quality assurance program covers all existing Seismic Class I structures, systems and components, including their foundations and supports.

Xn addi-tion, certain nonseismically design structures, systems or components may also be covered by the quality assurance program.

Modifications or additions to existing structures, systems and components are desiIgnated the same seismic classi-fication as the existing system.

New structures,

systems, and components shall be designated with a seismic classification in accordance with the guidelines in Regulatory Guide 1.29.

NOTE:

THIS LISTING XS INTENDED TO PROVIDE ONLY GUIDANCE XN THE DESIGNATXON OF SAFETY RELATED ITEMS ~

CLASS XFXCATION OF XNDIVIDUAL XTEMS I WHETHER OR NOT SHOWN IN THIS LIST, SHALL BE ACCOMPLISHED ON A CASE-BY-CASE BASIS-83iii50372 83ii04 i

l PDR ADOCN 05000244 PDR

S I'I I

1 i

QUALITY ASSURANCE MANUAL GINNA STATION TITLE APPENDIX A QUALITY AND SAFETY RELATED LISTINGS AND DIAGRAMS 49 90C DATE August 1, 198 PAGE 2

DF 8

2.1.1 Buildin s and Structures a ~

b.ci d.

e.

gi h.

3. ~

Containment (1) all penet'rations mechanical and electri-cal (to include piping up to and including the outermost. primary isolation valve)

(2) air locks (3) concrete shield (4) liner (5) interior structures Intermediate building (including cable tunnel)

Auxiliary building Control building (including wall common with turbine building)

Diesel generator rooms (including walls common with turbine building)

Screen house (portion housing Service Water and essential 480 volt busses and switchgear)

Spent fuel pit and storage racks Fuel transfer tube Containment crane Standby Auxiliary Feedwater Pump Building

2. 1.2 Reactor a 0 b.

c ~

d.

e.f; Vessel (including supporting and positioning members)>and head Vessel internals Fuel assemblies Full length control rod assemblies Full and part length CRDM housings Incore Instrumentation structure

2. 1.3 Reactor Coolant S stem a 0 b.

c ~

Pressurizer Steam generator and supports Reactor coolant pumps (1) casing and supports (2) main flange (3) thermal barriers (4)

Nl, N2 and N3 seals and housings (5) pressure retaining bolting

QUALITY ASSURANCE MANUAL GINNA STATION TITLE:

Ah'PENDIX A QUALITY AND SAFETY RELATED LISTINGS AND DIAGRAMS 49 90C DATE August 1, 1980 PAGE OF 8

d.

e.

Reactor coolant pump motors (1) shaft coupling and spool pieces (2) armature (3) flywheel (4) motor bolting piping and valves including hangers and supports shown in color on attached Drawing 33013-424.

2. 1.4 2.1.5 Sam lin S stem Sampling piping and valves shown in color on attached Drawing 33013-422 including hangers and supports.

En ineered Safet Features a 0 b.

c d.

e.

Sa fety Injection System (1)

Accumulators (2)

Safety injection pumps and motors (3)

Refueling water storage tank (4)

Piping and valves, including hangers and supports shown in color on attached Draw-ings 33013-425 and 33013-432.

Residual Heat Removal System (1)

Residual heat exchangers (2)

Residual heat removal pumps and motors (3)

Piping and valves, including hangers and supports shown in color on attached Draw-ings 33013-425'nd 33013-436.

Boric acid tanks Drawing 33013-426 Containment Spray System (1)

Containment spray pumps and motors (2)

Spray headers (3)

Spray additive tank and eductors (4)

Spray nozzles (5)

Piping and valves, including hangers and supports shown in color on attached Draw-ings 33013-425 and 33013-432.

Containment Air Recirculation Cooling and Filtration System Drawing 33013-533 (1)

Fans (2)

Post accident charcoal filter system (3)

Distribution system (4)

Cooling coils (5)

Ducting

TITLE:

OATE 49 90C QUALITY ASSURANCE MANUAL GINNA STATION APPENDIX A QUALITY AND SAFETY RELATED LISTINGS AND DIAGRAMS August 1, 1980 PAGE 4

OF 8

2.1.6 Reactor Control and Protection S stem a.

Reactor Protection System b.

All electric and mechanical devices and circuitry between the process and the input terminals of the actuator systems involved in generating signals that initiate protective action.

These signals include those that actuate reactor trip and safeguards such as containment isolation, core spray, safety injection, pressure reduction and air cleaning.

Reactor Control System (1)

Rod Control System (including power supplies and position indication systems)

(2)

Automatic and Manual rod control interlock systems 2.1.7 Process Instrumentation and Controls a ~

b.

C.

All electric and mechanical devices and circuitry between the process and the input terminals of the actuator systems involved in generating signals that initiate reactor protective action.

All electric and mechanical devices and circuitry~that monitor systems important to safety.

The following are examples of safety related process instrumentation and control parameters.

(1) containment pressure (2) steam generator pressure and level (3) refueling water storage tank and NaOH tank level (4) safety injection, residual heat removal and auxiliary feedwater flow (5) pressurizer pressure and level (6) control room radiation (7) reactor coolant temperature (8) certain pump and valve controls

QUALITYASSURANCE MANUAL GINNA STATION TITLE APPENDIX A QUALITY AND SAFETY RELATED LISTINGS AND DIAGRAMS 49 QOC DATE August 1, 1980 PAGE 5

DF 8

2.1.8 Chemical and Volume Control S stem a ~

b.

Ci d.

ef o g,h.

3. ~

k.

1.

m.

n.

oo p ~

q.r.

s ~

Volume control tank Boric acid tanks Charging

pumps, motors, and drives Regenerative heat exchanger Nonregenerative heat exchanger Exces's letdown heat exchanger Seal water heat exchanger Charging pump filter Reactor coolant filter housing Seal water return filter housing Seal injection filter housing Boric acid filter housing Letdown orifices RCP seal bypass orifices Boric acid blender Boric acid transfer pumps and motors Boric acid tank orifices CVCS demineralizers Piping and valves, including hangers.

and supports shown in color on attached Drawings 33013-426, 33013-427, 33013-433 and 33013-434.

2. 1. 9 Emer enc Power Su 1

S stem a ~

b.

c ~

Diesel Generators (including engine driven pumps, air intercooler and jacket liners)

Diesel Generator auxiliary systems shown on Drawing 33013-539 (1)

Cooling water system (including heat exchanger, piping, valves, and motor driven pump and tank)

(2)

Lubrication system (including heat exchanger, piping, valves;" and motor dr>.ven pump)

(3)

Starting system (including air storage tanks, piping, valves Excluding air compressors)

(4)

Fuel oil system (including storage tanks transfer pump) 480 volt safeguards system (1)

Bus 14, 16, 17 and 18 switchgear and protective devices (2)

Safeguard motor control centers (1C, 1D~

1Gl~

1G2g ILg IM)

(3)

Safeguard system cables and cable trays

I

TITI.E:

DATE 40 QOC QUALITY ASSURANCE MANUAL GINNA STATION APPENDIX A QUALITY AND SAFETY RELATED LIS TINGS AND DIAGRAMS August 1, 1980 PAGE 6

DF 8

d.

e.

125 VDC system including the station batteries and racks AC Instrument buses

2. 1. 10 Steam and Power Conversion S stem a 0 b.

c ~

d.

e.

Main steam piping from steam generators to MSIV's, including hangers and supports shown in color on attached Drawing 33013-534.

MISV's including actuators Main steam safety valves Main steam power operated relief valves Feedwater piping, including hangers, supports and valves shown in color on attached Drawing 33013-544.

Blowdown piping including hangers, supports and valves shown in color on attached Drawing 33013-522.

2. 1. 11 Waste Dis osal S stem a ~

b.

c ~

de e.f.

g ~

h.

Waste holdup tanks Sump tank Gas decay tanks Waste.gas compressors Waste evaporator feedpump Sump tankIpumps Spent. resin storage tanks Piping including hangers and supports and valves shown in color on attached Drawings 33013-423, 33013-429, 33013-430, and 33013-431.

2. l. 12 Auxiliar Feedwater S stem a ~

b.

c ~

Auxiliary feedwater pumps (turbine and motor driven)

Auxiliary feedwater pump motors and turbine drive Piping and valves, including hangers and

supports, shown in color on attached Drawing 33013-544.

i

TITLE DATE 40 OOC QUALITY ASSURANCE MANUAL GINNA STATION APPENDIX A QUALITY AND SAFETY RELATED

'ISTINGS AND DIAGRAMS August 1, 1980 PAGE DF 8

2. 1. 13 Standb Auxiliar Feedwater S stem a ~

b.

c Standby auxiliary feedwater pumps Standby auxiliary feedwater pump motors Piping and valves, including hangers and supports shown wi.th boundaries noted in Drawing D-302-071 2.1. 14 Com onent Coolin S stem a 0 b.

c ~

d.

Component cooling pumps and motors Component cooling surge tank Component cooling heat exchangers Piping and valves, including hangers and supports shown in color on attached Drawings 33013-435 and 33013-436.

2.1. 15 Service Mater S stem a ~

b.

Service water pumps and motors Piping and valves, including hangers.

and

supports, shown in color on attached Drawing 33013-529.
2. 1. 16 Handlin E ui ment a ~

b.

c d.

Manipulator crane*

Auxiliary'uilding crane*

Spent fuel pit crane*

Drumming area crane*

2. 1. 17 3.0 Low Temperature Overpressure Protection
System, Catalytic Drawing A-202.

S stem Flow Drawin s 3.1 Detailed flow drawings of the safety related systems are shown in Attachment 1 to this Appendix.

  • These cranes were classified as nonseismic equipment, but parts of each were originally specified for procurement as meeting Class I design requirements.

There

may, however, be some seismic design require-ments for some of these cranes.

TITLE:

DATE 40 OOC QUALITY ASS U RANC E MANUAL GINNA STATION APPENDIX A QUALITY AND SAFETY RELATED LISTINGS AND DIAGRAMS August 1, 198 0 PAGE OF 8

4.0 Consumables Utilized in Safet Related Structures S stems and Com onents 4.1 This listing is intended as a guide for procurement and receipt acceptance of consumables whose quality may have significant impact on maintaining the integrity of safety-related structures, systems and components as listed in 2.0 of this Appendix.

Quality requirements are applied only"to the extent necessary to ensure that the safety related struc-

ture, system or component will fulfillits safety function.

a 0 b.

c ~

d.

e.f.

g.h.

1 ~

Resins (used in CVCS)

Bulk Boric Acid (used in CVCS and RCS)

Sodium Hydroxide (used in Containment Spray System)

Lithium Hydroxide (used in CVCS and RCS)

Hydrogen (used in CVCS and RCS)

Diesel Fuel Oil (used in Emergency Diesel Generators)

Hydraulic Fluid (used as a medium for snubbers)

Insulation materials (installed on or adjacent to stainless steel systems and components)

NDE Materials (1)

Liquid Penetrant, Developer, Cleaner (2)

Ultrasonic Couplant Marking and Coverings on austenitic stainless steel equipment and components (marking pens, protective coatings, tape, etc.)

l