ML17250B297

From kanterella
Jump to navigation Jump to search
Rev 8 to EOP ES-0.0, Rediagnosis
ML17250B297
Person / Time
Site: Ginna Constellation icon.png
Issue date: 06/16/1993
From:
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17250B293 List:
References
ES-.0, ES-0.0, NUDOCS 9307080221
Download: ML17250B297 (14)


Text

EOP:

ES-O.O REDIAGNOSIS REV:

8 PAGE 1 of 4 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW'ORC REVIEW DATE PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:

9307080221 930628 PDR ADOCK 05000244 P

PDR

4I 1,

S

ES-O.O REDIAGNOSIS REV:

8 PAGE 2 of 4 A.

PURPOSE This procedure provides a mechanism to allow the operator to determine or confirm the most appropriate post accident recovery procedure.

B.

ENTRY CONDITIONS/SYMPTOMS 1.

ENTRY CONDITIONS This procedure is entered based on operator judgement.

EOP:

ES-0

~ 0 REDIAGNOSIS REV:

8 PAGE 3 of 4 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED NOTE:

o FOLDOUT page should be open and monitored periodically.

o This procedure should only be used if SI is in service or is required.

o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation i.s greater than 10+

R/hr.

1 Check If Any S/G Secondary, Side Is Intact a.

Check pressures in all S/Gs ANY S/G STABLE OR INCREASING

a. IF a controlled cooldown is in
progress, THEN GO TO Step 2.

IF NOT, THEN the following applies:

o IF main steamlines NOT

isolated, THEN you should be in E-2, FAULTED STEAM GENERATOR ISOLATION.

-OR-o IF main steamlines

isolated, THEN you should be in ECA-2.1, UNCONTROLLED DEPRESSURIZATION OF BOTH STEAM GENERATORS.

2 Check If S/G Secondary Side Is Intact:

Verify faulted S/G isolated unless needed for RCS cooldown:

o Pressure in both S/Gs

- STABLE OR INCREASING o

Pressure in both S/Gs GREATER THAN 100 PSIG o

Steamlines o

Feedlines IF NOT THEN you should be in E-2, FAULTED STEAM GENERATOR ISOLATION, Step 1

ES-O.O REDIAGNOSIS REV:

8 PAGE 4 of 4 STEP ACTION/EXPECTED RESPONSE

RESPONSE

NOT OBTAINED 3

Check If S/G Tubes. Are Ruptured:

o ANY S/G LEVEL INCREASING IN AN UNCONTROLLED MANNER You should be in an E-l or ECA-1 series procedure.

-OR-o ANY S/G WITH HIGH RADIATION 4

You Should Be In An E-3 Or ECA-3 Series Procedure

-END-

0

EOP $

ES-O.O T!TLE$

REDIAGNOSIS REV:

8 PAGE 1 of 1 ES-O.O APPENDIX LIST TITLE PAGES 1)

FIGURE MIN SUBCOOLING 2)

FOLDOUT

EOP:

ES-O.O T!TLE:

REDIAGNOSIS REV:

8 PAGE 1 of 1 FIGURE MIN SUBCOOLING NOTE:

Subcooling Margin = Saturation Temperature From Figure Below [-] Core Exit T/C Indication S

PRESSURE (PSIG)

RC 2500 2400 2300 2200 2100 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0

20 RCS PRESSURE INCREHENTS 20 PSIG SUBCOOLED REGION INADEQUATE SUBCOOLING REGION ADVERSE CNHT TEHPERATURE INCREHENTS 10'F NORMAL CNHT 0

250 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEHPERATURE ('F)

I C

1, 0

EOP:

ES-O.O TITLE:

REDIAGNOSIS REV:

8 PAGE 1 of 1 FOLDOUT PAGE 1.

'CP TRIP CRITERIA IF BOTH conditions listed below occur, THEN trip both RCPs:

a.

SI pumps AT LEAST TWO RUNNING b.

RCS pressure minus maximum S/G pressure LESS THAN 175 PSIG

[400 psig adverse CNMT]

2 ~

SI ACTUATION CRITERIA IF ANY condition listed below occurs, THEN actuate SI and go to E-O, REACTOR TRIP OR SAFETY INJECTION, Step 1:

o RCS subcooling based on core exit T/Cs LESS THAN O'F USING FIGURE MIN SUBCOOLING

-OR-o PRZR level LESS THAN 54

[,304 adverse CNMT]

AND RCS subcooling based on core exit T/Cs LESS THAN 20'F USING FIGURE MIN SUBCOOLING

-OR=

o Any automatic SI setpoint is reached 3 ~

SI PUMP AUTO SWITCHOVER CRITERION WHEN BAST level decreases to 104, THEN ensure SI pump automatic switchover to RWST.

4 ~

AFW SUPPLY SWITCHOVER CRITERION IF CST level decreases to less than 5 feet, THEN switch to alternate AFW water supply (Refer to ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS)

~