Text
',ACCELERATED DISTRIBUTION DEMONSTRATION SYSTEM
.~
e REGULATORY =INFORMATION DISTRIBUTION SYSTEM (RIDS)
..ACCESSION NBR:9103250391 DOC.DATE: 91/02/28 NOTARIZED: NO FACIL:50-335 St. Lucie Plant, Unit 1,.Florida Power
& Light Co.
50-389 St. Lucie Plant, Unit 2, Florida Power
& Light Co.
AUTH.NAME AUTHOR AFFILXATXON BREEN,J.J.
Florida Power
& Light Co.
.SAGER,D.A.
Florida Power
& Light Co.
RECIP.NAME RECIPIENT AFFILIATION
SUBJECT:
Monthly operating repts for Feb 1991 for St.Lucie Units 1
& 2.W/910315 ltr.
DISTRIBUTION CODE:
IE24D COPIES RECEIVED:LTR
(
ENCL Q SIZE:
TITLE: Monthly Operating Report (per Tech Specs)
NOTES
- DOCKET, 05000335 05000389 R
I D
RECIPIENT ID CODE/NAME PD2-2 LA NORRIS,J INTERNAL: ACRS AEOD/DSP/TPAB NRR/DOEA/OEAB RGN2 EXTERNAL: EG&G BRYCE,J.H NSXC COPIES LTTR ENCL 3
3 1
1 10 10 1
1 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME PD2-2 PD AEOD/DOA NRR/DLP EB1 0 R
NRC PDR COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 D
D S
D NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM P 1-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 24 ENCL 24 D
D
e J
rl
P.O. Box 128, Ft. Pierce, FL 34954-0128 MAR 1 5 199}
L-91-74 10 CFR 50.36 U. S. Nuclear Regulatory Commission Attn:
Document Control Desk Washington, DC 20555 Gentlemen:
Re:
St. Lucie Units 1 and 2
Docket Nos.
50-335 and 50-389 Monthl 0 eratin Re ort Attached are the February 1991 Operating Status and Summary of Operating Experience Reports for St. Lucie Units 1 and 2.
Very truly yours, 446 D. A.
S ger Vice r sident St. Lucie Plant DAS JJB kw cc: Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant Attachments DAS/PSL N381 9103250391 910228 PDR ADOCK 05000335 R
PDR g~QE. q ra anFPLGroop company SE2v-
'/I
A
~
~
J
/
T
'k gE I
AVERAGE DAILY UNIT POSER LEVEL DOCKET NO ~
50>>335 I~
COMPLETED BY J.J.
Breen MONTH FEBRUARY 1991 DAY AVERAGE DAILY POSER LEVEL (MRe-Net) 2/ 1/91 2/ 2/91 2/ 3/91 2/ 0/91 2/ 5/91 2/ 6/91 2/ 7/91 2/ 8/91 2/ 9/91 2/10/91 2/il/91 2/12/91 2/13/91 2/10/91 2/15/91 2/16/91 2/17/91 2/18/91 2/19/91 2/20/91 2/21/91 2/22/91 2/23/91 2/24/91 2/25/91 2/26/'91 2/27/91 2/28/91 861 S63 864 860 866 860 863 861 865 867 867 867 867 868 866 868 870 870 867 803 723 825 867 866 866 867 868 868
OPERATING DATA REPORT OPERATING STATUS DOCKET NO 58 335 DATE R
< z 1991 COMPLETED BY J. J.
'BREEN TELEPHONE 487/465/3558 UNIT NAME'Ti LUCXE UNIT 1
2i REPORTING PERIOD+
FEBRUARY 1991 3+
LICENSED THERMAL POHER (MHT)o 2780 4,
NAMEF LATE RATING (GROSS MWE>;
858 5i DESXGN ELECTRICAL RATING (NET MHE)i 830 6,
MAXXMUM DEPENDABLE CAPACITY (GROSS MHE>:
872 7i MAXIMUM DEPENDABLE CAPACXTY (NET MME):
839 8,
XF CHANGES OCCUR XN CAPACXTY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SXNCE LAST REPORT~
GXVE REASONS',
POWER LEVEL TO WHICH RESTRICTED~
XF ANY (NET MHE) 18'EASONS FOR RESTRXCTXONSr XF ANY'MONTHLY
-YTD-CUMULATXVE 11.
HOURS XN REPORT PERIODS 12'UMBER OF HOURS REACTOR HAB CRXTXCAL 13.
REACTOR RESERVE SHUTDOWN HOURS 14'OURS GENERATOR QN-LXNE 15'NIT RESERVE SHUTDOHN HOURS 16'ROSS THERMAL ENERGY GENERATED
<MHH) 17'ROSS ELECTRXCAL ENERGY GENERATED (MWH) 18'ET ELECTRICAL ENERGY GENERATED (MHH) i.9i UNXT SERVXCE FACTOR 28'NXT AVAXLABXLXTYFACTOR 21 CAPACITY FACTOR (USXNG MDC NET) 22'APACXTY FACTOR
<USING DER NET) 23+
UNIT FORCED OUTAGE RATE 24, BHUTDOHNS SCHEDULED OVER NEXT 6 MONTHS 672 672i8 8i8 672i8 8i8 1800859 607240 576922 188' 188+8 182i3 183i4 8+8 1416 1397i5 8+8 1393i8 8+8 3717230 1249130 1185622 98i4 98+4 99' 100' 8e8 124392.0 94356i8 285 3
93498+1 39i3 240959284 79457770 75878364 75o2 75+2 74+8 73.8 4.3 25 XF SHUT DOWN AT END OF REPORT PERIOD~
ESTIMATED DATE OF STARTUP:
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.
50-335 UNIT NAME ST LUCIEUNIT 1 DATE 1991 COMPLETED BY J. J. BREEN TELEPHOHE 6440460 550 REPORT MONTH FEBRUARY 1
1 No.
Date Type Duration (Hours)
Reasons Method of Shutting Down Reactor Licensee Event Report System Codes Component Code Cause &Corrective Action to Prevent Recurrence Unit 1 remained at fullpower for the month of February.
F Forced S
Shutdown Reason A - Equipmcnt failure (explain)
B - Maintenance or Test C - Refueling D - Regulatory restriction E - Operator Training R License Examination F - Administrative G - Operational Error (Expalin)
H - Other (Explain)
Method 1 - Manual 2 - Manual Scram 3 - Automatic Scram 4 - Continued 5 - Load Reduction 9 - Olher (Explain)
Exhibit G - Instructions for Preparation ofData Entry Sheets Liccnsce Event Report (LER) File (NUREG-0161)
Exhibit 1 - Same Source
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO ~
50-335 DATE COMPLETED BY reen TELEPHONE 407 465-3550 REPORT MONTH FEBRUARY 1991 For the month of February Unit 1 remained at full power.
In accordance with the requirements of Technical Specification 6.9.1.6, there were no challenges to the PORVs or safety valves during the report period.
AVERAGE DAILY UNIT POlifER LEVEL DOCKET NO ~
50-389 DATE COMPLETED BY
. Breen MONTH FEBRUARY 1991 DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 2/ 1/91 2/ 2/91 2/ 3/91 2/ 4/91 2/ 5/91 2/ 6/91 2/ 7/91 2/ 8/91 2/ 9/91 2/10/91 2/1 1/91 2/12/91 2/13/91 2/14/91 2/15/91 2/16/91 2/17/91 2/18/91 2/19/91 2/20/91 2/21/91 2/22/91 2/23/91 2/24/91 2/25/91 2/26/91 2/27/91 2/28/91 865 869 870 871 871 870 869 869 871 872 872 873 873 873 871 873 874 874 873 871 869 868 868 868 855 866 870 871
Qr ERATING DATA RE> QRT OPERATING STATUS DOCI<ET NO 58 389 DATE cavrczvzo sv 8>"JARw TELEPHONE 407/465/3558 1>>
UNXT NAME>>
BT>>
LUCXE UNXT 2 2>>
REPORTXNG PERTOD>>
FEBRUARY 1991 3>>
LICENSED THERMAL POWER
<MWT)>>
27ee 4>>
NAMEPLATE RATING (GROSS MWE)>>
858 5>>
DEBXGN ELECTRICAL RATING <NET MWE):
830 6>>
MAXIMUM DEPENDABLE CAPACXTY (GROSS MWE)>>
882 7>>
MAXIMUM DEPENDABLE CAPACITY (NET MWE)>>
839 8>> IF CHANGES OCCUR IN C*PACXTY RATINGS (XTEMB NUMBER 3 THROUGH 7)
SINCE LAST REPORTr GXVE REASONS>>
9, POWER LEVEL TQ WHICH REBTRICTEDr XF ANY (NET MWE) 10>>
REASONS FOR RESTRXCTXONBr XF ANY>>
MONTHLY
-YTD-CUMUL'ATIVE HOURS XN REPORT PERIODS 12 NUMBER OF HOURS REACTOR WAS CRXTXCAL 13 REACTOR RESERVE SHUTDOWN HOURS 14, HOURS GENERATOR ON-LXNE 15>>
UNIT RESERVE SHUTDOWN HOURS 16>>
GROSS THERMAL ENERGY GENERATED (MWH) 17>>
GROSS ELECTRXCAL. ENERGY GENERATED (MWH) 18>>
NET ELECTRIC*L ENERGY GENERATED
<MWH) 19>>
UNXT SERVXCE FACTOR 20, UNXT AVAILABXLXTYFACTOR 21>>
CAPACITY FACTOR (USXNG MDC NET) 22.
CAPACITY FACTOR (USING DER NET) 23 UNIT FORCED QUTAGE RATE 24>>
SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS 672 672>>0 0>>0 672>>0 0>>e 1813283 615200 584588 108>>0 ice,O 103>>7 104>>8 0>>0 1416 1416>>0 0>>0 1416>>0 0>>0 3821022 1294880 123e368 100>>e 180>>0 103>>6 104>>7 0>>0 66289>>0 56276.3 0>>0 55260>>3 0>>0 144610103 48191800 45564471 83>>4 83.4 83>>5 83>>6 5>>8 25>>
XF SHUT DOWN AT END OF REPORT PERIODr ESTXMATED DATE OF BTARTUP>>
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NQ.
~5UBB UNITNANB
~BLUCIB Nl 2
DATE
~191 COMPLETED BY J. J. BREEN TELEPHQPN NQQ 65-3550 REPORT MONTH FEBRUARY 1
1 No.
Date Type Duration (Hours)
Reasons Method of Shutting Down Reactor Licensee Event Report System Codea Component Code'ause
&Corrective Action to Prevent Recurrence Unit 2 remained at fullpower for the month of February.
F Forced S
Shutdown Reason A-Equipment failure (explain)
B - Maintenance or Test C - Refueling D - Regulatory restriction E - Operator Training 8c License Examination F - Administrative G - Operational Error (Expalin)
H - Other (Explain)
Method" 1 - Manual 2 - Manual Scram 3 - Automatic Scram 4 - Continued 5 - Load Reduction 9 - Other (Explain)
Exhibit G - Instructions for Preparation of Data Entry Shccts Licensee Event Report (LER) File (NUREG4161)
Exhibit 1 - Same Source Nlssl FPL
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO.
50-389 UNIT St. Lucie 2
COMPLETED BY J.J.
Breen TELEPHONE 407 465-3550 REPORT MONTH FEBRUARY 1991 For the month of February Unit 2 remained at full power.
In accordance with the requirements of Technical Specification 6.9.1.6, there were no challenges to the PORVs or safety valves during the report period.