':Docket Nos.
50-335 and 50-389 Mr. J.
H.
Go ldberg Executive Vice President F lorida Power and Light Company Post Office Box 14000 Juno Beach, Florida 33408-0420
Dear Mr. Goldberg:
January ll, 1990 D ISTR IBUTION--, Il.k I
NRC 8
LPDRs J. Norris PD22 Rdg Fi le S.
Varga 14/E/4 C.k Hehl 14/H/3 D. Miller OGC E. Jordan MNBB-3302 ACRS(10)
M. Sinkule RII,
SUBJECT:
GENERIC LETTER 89 SAFETY-RELATED MOTOR-OPERATED VALVE TESTING AND SURVEILLANCE - ST.
LUCIE PLANT, UNITS 1
AND 2 By letter dated December 28, 1989, you responded to Generic Letter 89-10.
In that letter you requested a copy of NRC's cost-benefit analysis prepared in connection with this generic letter.
Accordingly, I am enclosing the requested cost-benefit ana lysis.
Please note that only a copy of the cover of Enclosure 2 (NUREG/CR-5140) to Generic Letter 89-10 is included in the package.
The document itself can be obtained from the Superintendent of Documents, U.S.
Government Printing Office, P.O.
Box 37082, Washington, D.C. 20013-7892 and from the National Technical Information Service, Springfield, Virginia 22161.
Sin cere ly, Original signed by
Enclosure:
As stated cc w/enclosure:
See next page Jan A. Norris, Sr. Project Manager Project Directorate II-2 Division of Reactor Projects-I/I I Office of Nuclear Reactor Regulation NAME:D'r DATE:01/yi/90
- Not
- 0%/ i i jkd:
/90 HBerkow
>>>>>> +>>>>>>>>+>>e 01/$ $ /90 OFFICIAL RECORD COPY Document Name:
GENERIC LTR 8910/ST.
LUCIE 9005230227. 900il.l.
PDR ADOCK 05000335 P
1 v
~
1
Hr.
- 1. H. Goldberg Florida Power 5 Light Company St. Lucie Plant CC:
Nr. Jack Shreve Offi ce of the Public Counsel Room 4, Holland Building Tallahassee, Flori da 32304 Senior Resident Inspector St. Lucie Plant U.S. Nuclear Regulatory Commission 7585 S.
Hwy A1A Jensen Beach, Florida 33457 State Planning 5 Development Clearinghouse Office of Planning 5 Budget Executive Office of the Governor The Capitol Building Ta 1 lahassee, Florida 32301 Harold F. Reis, Esq.
Newman 5 Holtzinoer 1615 L Street, N.W.
Washington, DC 20036 John T. Butler, Esq.
- Steel, Hector and Davis 4000 Southeast Financial Center Miami, Florida 33131-2398 Administrator Department of Environmental Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301 Nr. Weldon B. Lewis, County Administrator St. Lucie County 2300 Virginia Avenue, Room 104 Fort Pierce, Florida 33450 Hr. Charles B. Brinkman, Manager Washington Nuclear Operations Combustion Engineering, Inc.
12300 Twinbrook Parkway, Suite 330 Rockville, Maryland 20852 t1r. Jacob Daniel Nash Office of Radiation Control Department of Health and Rehabilitative Services 1317 Winewood Blvd.
Tallahassee, Florida 32399-0700 Regional Administrator, Region II
'.S.
Nuclear Regulatory Commission 101 tiarietta Street N.W., Suite 2900 Atlanta, Georgia 30323