MONTHYEARML16036A3072016-02-18018 February 2016 Regulatory Audit Plan in Support of the License Amendment Requests to Implement Risk-Informed Technical Specifications Initiative 4b Project stage: Other ML16105A4592016-04-14014 April 2016 NRR E-mail Capture - Request for Additional Information Re. Turkey Point 3 & 4 LAR-236 (CACs MF5455 & MF5456) Project stage: RAI ML16110A0042016-04-18018 April 2016 NRR E-mail Capture - Request for Additional Information - Turkey Point 3 & 4 LAR-236 (CACs MF5455 & MF5456) Project stage: RAI ML16154A3392016-06-0101 June 2016 NRR E-mail Capture - Request for Additional Information Re. Turkey Point 3 & 4 LAR-236 (CACs MF5455 & MF5456) Project stage: RAI L-2016-116, Response to Request for Additional Information Regarding License Amendment Request 236, Revision to TS to Adopt Risk Informed Completion Time TSTF-505, Revision 1,Provide Risk-Informed Extended Completion Times2016-06-16016 June 2016 Response to Request for Additional Information Regarding License Amendment Request 236, Revision to TS to Adopt Risk Informed Completion Time TSTF-505, Revision 1,Provide Risk-Informed Extended Completion Times Project stage: Response to RAI ML16154A0122016-06-21021 June 2016 Summary of NRC Audit of Turkey Point Nuclear Generating Unit Nos. 3 and 4 for License Amendment Request No. 236 Project stage: Other L-2016-136, Second Response to Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide.2016-08-11011 August 2016 Second Response to Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide. Project stage: Response to RAI L-2016-213, Response to Request for Additional Information Regarding License Amendment Request 245, Change to the Technical Specifications to Address an Inoperable Steam Supply for the Auxiliary Feedwater Pumps2016-11-15015 November 2016 Response to Request for Additional Information Regarding License Amendment Request 245, Change to the Technical Specifications to Address an Inoperable Steam Supply for the Auxiliary Feedwater Pumps Project stage: Response to RAI L-2017-006, Supplement to License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed Extended Completion Times RITSTF Initiative 4b2017-02-0909 February 2017 Supplement to License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed Extended Completion Times RITSTF Initiative 4b Project stage: Supplement ML17090A1252017-03-30030 March 2017 NRR E-mail Capture - Request for Additional Information Re. Turkey Point TSTF-505 LAR 236 (CACs MF5455 and MF5456) Project stage: RAI L-2017-063, Response to Third Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide .2017-04-27027 April 2017 Response to Third Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide . Project stage: Request ML17213A2102017-06-27027 June 2017 NRR E-mail Capture - Draft Request for Additional Information - Turkey Point 3 & 4 LAR-236 (CACs MF5455 & MF5456) Project stage: Draft RAI ML17222A2312017-07-18018 July 2017 NRR E-mail Capture - Draft Request for Additional Information - Turkey Point 3 & 4 LAR-236 (CACs MF5455 & MF5456) Project stage: Draft RAI ML17222A0042017-08-0303 August 2017 NRR E-mail Capture - Additional Draft RAI Related to the Turkey Point TSTF-505 LAR Project stage: Draft RAI ML17223A0612017-08-10010 August 2017 NRR E-mail Capture - Request for Additional Information - Turkey Point 3 & 4 LAR-236 (CACs MF5455 & MF5456) Project stage: RAI L-2017-168, Response to Fourth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed2017-10-30030 October 2017 Response to Fourth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed Project stage: Request L-2018-001, Supplement to Response to Fourth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide2018-02-15015 February 2018 Supplement to Response to Fourth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Project stage: Supplement ML18061A0172018-03-0101 March 2018 NRR E-mail Capture - Turkey Point Nuclear Generating Unit Nos. 3 and 4, Request for Additional Information Regarding License Amendment Request 256 (CAC Nos. MF5455 and MF5456; EPID L-2014-0002) Project stage: RAI L-2018-061, Response to Fifth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed....2018-03-22022 March 2018 Response to Fifth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed.... Project stage: Request L-2014-000, Response to Fifth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed..2018-03-22022 March 2018 Response to Fifth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed.. Project stage: Request ML18138A0002018-04-19019 April 2018 NRR E-mail Capture - Draft Request for Additional Information - Turkey Point 3 and 4 LAR 236 (CAC Nos. MF5455 and MF5456; EPID L-2014-0002) Project stage: Draft RAI ML18138A4652018-05-17017 May 2018 NRR E-mail Capture - Turkey Point Nuclear Generating Unit Nos. 3 and 4, Request for Additional Information Regarding License Amendment Request 236 (CAC Nos. MF5455 and MF5456; EPID L-2014-0002) Project stage: RAI L-2018-118, Response to Sixth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed2018-06-12012 June 2018 Response to Sixth Request for Additional Information Regarding License Amendment Request 236, Revision to the Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 1, Provide Risk-Informed Project stage: Request ML18151A4342018-06-14014 June 2018 Summary of NRC Audit Regarding License Amendment Request to Adopt Risk-Informed Completion Times in Technical Specifications (CAC Nos. MF5372 and MF5373; EPID L-2014-LLA-0002) Project stage: Other ML18303A2432018-10-26026 October 2018 NRR E-mail Capture - (External_Sender) NRC Notification of State of Florida Regarding Turkey Point 3 and 4 License Amendments - Regarding the Addition of Risk-Informed Completion Times Project stage: Other ML18270A4292018-12-0303 December 2018 Issuance of Amendments Nos. 284 and 278 Regarding Adoption of Risk-Informed Completion Times in Technical Specifications (CAC Nos. MF5455 and MF5456; EPID L-2014-LLA-0002) Project stage: Approval 2017-06-27
[Table View] |
Text
1 NRR-PMDAPEm Resource From:
Wentzel, Michael Sent:
Thursday, August 03, 2017 11:19 AM To:
Catron, Steve; Kilby, Gary; Hanek, Olga Cc:
Mack, Jarrett; Guth, Mitch
Subject:
Additional Draft RAI Related to the Turkey Point TSTF-505 LAR (CAC Nos MF5455 and MF5456)
Steve, Gary, and Olga, On our July 10 clarification call with you and staff from the U.S. Nuclear Regulatory Commissions (NRCs)
Probabilistic Risk Assessment (PRA) Licensing Branch (APLA), the staff notified you of the likelihood of an additional request for additional information (RAI) related to its review of the license amendment request (LAR) to implement TSTF-505, Revision 1, at Turkey Point. The NRC staff has determined that the below information is necessary to complete its review of the subject LAR.
As previously discussed, the goal is to issue all of the TSTF-505 RAIs in a single request. To facilitate that, I request that you let me know by Monday, August 7, 2017, if a clarification call is needed and if the draft RAI contains any proprietary information.
If you have any questions or would like to discuss further, please let me know.
- Thanks, Mike APLA RAI 18 Dual-Unit RICT Calculations Various TS action statements for which a RICT is being proposed (e.g., TS 3.8.2.1 ACTION A), appl[y] to both units simultaneously. Enclosure 1 of the LAR states that, [f]ollowing 4b implementation, the actual RICT values will be calculated on a unit-specific basis, using the actual plant configuration and the current revision of the PRA model representing the as-built, as-operated condition of the plant. Please clarify how the two units will calculate and apply a RICT to both units simultaneously. Specifically:
a) Confirm there are two complete and independent baseline PRAs (i.e., one for each unit).
- 1. If not, summarize the available baseline PRA models.
- 2. If the licensee is not using two complete and independent baseline PRAs, but plan to develop and use two independent configuration risk management program (CRMP) logic models, summarize how the single (but adaptable) baseline PRA model will be transformed into two independent CRMP models.
b) If two independent CRMP logic models will be developed and used:
- 1. Explain how a RICT will be simultaneously estimated for each unit considering that different SSCs may be out of service in the different units.
- 2. Summarize any anticipated interactions between the two models being run independently but simultaneously that could affect the RICT estimates.
c) If two independent CRMP models will not be developed:
2
- 1. Explain how the unit specific RICT calculations will be appropriately estimated given any differences between the units, interactions between the units caused by shared equipment, and different out of service SSCs in each unit.
Hearing Identifier:
NRR_PMDA Email Number:
3651 Mail Envelope Properties (Michael.Wentzel@nrc.gov20170803111900)
Subject:
Additional Draft RAI Related to the Turkey Point TSTF-505 LAR (CAC Nos MF5455 and MF5456)
Sent Date:
8/3/2017 11:19:11 AM Received Date:
8/3/2017 11:19:00 AM From:
Wentzel, Michael Created By:
Michael.Wentzel@nrc.gov Recipients:
"Mack, Jarrett" <Jarrett.Mack@fpl.com>
Tracking Status: None "Guth, Mitch" <Mitch.Guth@fpl.com>
Tracking Status: None "Catron, Steve" <Steve.Catron@fpl.com>
Tracking Status: None "Kilby, Gary" <Gary.Kilby@fpl.com>
Tracking Status: None "Hanek, Olga" <Olga.Hanek@fpl.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 2678 8/3/2017 11:19:00 AM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: