Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in IE Insp Rept 50-335/79-20
ML17207A553
Person / Time
Site: Saint Lucie 
Issue date: 11/06/1979
From: Sutherland J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
Shared Package
ML17207A555 List:
References
NUDOCS 7911130064
Download: ML17207A553 (2)


See also: IR 05000335/1979020

Text

0

4~

~O

>>>>*++

In Reply Refer To:

RII:RWZ

50-335/79-20

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTAST., N.W., SUITE 3100

ATLANTA,GEORGIA 30303

NOV 06 1979

Florida Power

and Light Company

ATTN:

R. E. Uhrig, Vice President

Advanced

Systems

and Technology

P. 0.

Box 529100

Miami, Florida

33152

Gentlemen:

Thank you for your letter of October

16, 1979, informing us of the steps

you have taken to correct the items of noncompliance

concerning activities

under

NRC Operating License No. DPR-67 brought to your attention in our

letter of September

21, 1979.

We have reviewed your request for down-

grading item A in the Notice of Violation, Appendix A of our September

21,

1979 letter, to an open item.

Your response

admits that the prerequisite

tests of ANSI-N510 were not performed at the time of the system modification

and,

as such,

the item cannot be downgraded.

We will examine your corrective

actions

and plans during subsequent

inspections.

We appreciate

your cooperation with us.

Sincerely,

FJack T. Sutherland,

Chief

Fuel Facility and Materials

Safety Branch

cc:

C. M. Wethy, Plant Manager

P. 0.

Box 128

Ft. Pierce, Florida

33450

Nat Weems, Assistant

QA Manager

P.

O.

Box 128

Ft. Pierce,

Florida