Confirms 900122 Telcon Re Util Actions to Satisfy Requirements of Confirmatory Action Ltr CAL-RIII-90-01,per Reactor Scram Caused by Loss of Condensate Booster Pump. Results of Investigation of Equipment Failure Requested
ML17202G761
Person / Time
Site: Dresden 
Issue date: 01/25/1990
From: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Reed C
COMMONWEALTH EDISON CO.
References
CAL-RIII-90-01, CAL-RIII-90-1, NUDOCS 9001310242
Download: ML17202G761 (4)


Text

.*

'i

'~*..

e i.*

  • January 9, 1990
  • Docket Nos. 50-237/249 and 50-254/265 DJSIRIB_UlI ON

. Lrto_cket FiJe::::J NRC & Loca 1 PDRs PDIII-2 r/f Lluther JCraig TRoss BSiegel OGC Thomas J.. Kovach EJordan

Nuclear Licensing Manager FWitt CYCheng Commonwealth Edison Company-Suite 300 GHill (16)

  • EBrach OPUS West III.

RZimmerman fti' TMartin '&1° 1400 OPUS Place AGibson Ru:

  • HMi l ler Rllt

SUBJECT:

ENVIRONMENTAL.QUALIFICATION OF MOBI'L GREASES FOR LIMITORQUE ACTUATORS FOR THE DRESDEN AND QUAD CITIES STATIONS (TAC NOS...

67158 AND 67159).

Dear Mr. Kovach:

During the NRC Diagnostic Evaluation Team Inspection at th~ Dresde~ Nuclear Power Station in August 1987, the use of an apparently unqualified grease for Limitorque drywell motor-operated valves was identified.

By letter dated January 22, 1988 you committed to environmentally qualify these greases.

In~

letter dated October 11, 1989, you transmitted a test report which contained the results of a test program at Wyl~ Laboratories that evaluated t~e ~ccepta bil ity of Mobil greases Mobilux EPO, EPl and EP2 and Mobilgrease 28 for use in Limitorque actuators at Dresden and Quad Cities. The staff has reviewed this report and determined that the Mobil greases are environmentally qualified and that the maintenance and surveillance program on Limitorque actuators to be performed every *other refueling ou~age or approximately every 3 years to ensure operability is acceptable. The *staff's Safety Evaluation, which is enclosed, concludes that the use of Mobil greases as a substitute for the currently used Exxon greases is acceptable. Therefore, this issue is resolved.

Original signed by Byron L. Siegel, Project Manager Project Directorate III-2 Division of Reactor Projects - III, IV, V and Special Projects Original signed by Thierry M. Ross, Project Manager

. Project.Directorate III-2

' (

90011600iO PDR. ADOCK Q

900109 05000237 PNU Division of Reactor Projects - III, IV, V and Special Proj~cts I,

Enclosure:

As stated

  • See previous PDIII-2:LA Lluther 1/02/89
  • .:J.

concurrence PDII I-2: PM BSiegel:ta 1/02/89 DOCUMENT NAME:

PDIII-2:PM TRoss 1/02/89

[KOVACH4]

  • ~c___..,-*

I-2:PO JCraig 1/02/89

(.

Docket Nos. 50-237/249 and 50-254/265 Thomas J. Kovach UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 January 9, 1990 Nuclear Licensing Manager Commonwealth Edison Company-Suite 300 OPUS West III 1400 OPUS Place Downers Grove, Illinois 60515

SUBJECT:

ENVIRONMENTAL QUALIFICATION OF MOBIL GREASES FOR LIMITORQUE ACTUATORS FOR THE DRESDEN AND QUAD CITIES STATIONS (TAC NOS~

67158 AND 67159)

Dear Mr. Kovach:

During the NRC Diagnostic Evaluation Team Inspection at the Dresden Nuclear Power Station in August 1987, the use of an apparently unqualified ~rease for Limitorque drywell motor-operated valves was identified.

By letter dated January 22, 1988 you committed to environmentally qualify these greases.

In a letter dated October Jl, 1989, you transmitted a test report which contained the results of a test program at Wyle Labcratories that evaluated the accepta-bility of Mobil greases Mobilux EPO, EPl and EP2 and Mobilgrease 28 for use in t.imitorque actuators at Dresden and Quad Cities. The staff has reviewed this report and determined that the Mobil greases are environmentally qualified and that the maintenance and surveillance program on Limitorque actuators to be performed every other refueling outage or approximately every 3 years to ensure opera.bility is acceptable. The staff's Safety Evaluation, which is enclosed, concludes that the use of Mobil greases as a substitute for the currently used Exxon greases is acceptable. Therefore, this issue is resolved.

Enclosure:

As stated

~~~~roject Manager Project Directorate 111~2 Division of Reactor Projects - III, IV, V and Special Projects "If; //./?#

Thierry M. Ross, Project Manager Project Directorate III-2 Division of Reactor Projects - III, IV, V and Special Projects

Mr. lhomas J. Kovach Conmonwealth Edison Company cc:

Michael I. Miller, Esq.

Sidley and Austin One First National Plaza Chicago, Illinois 60603 Mr. J. Eenigenburg Plant Superintendent Dresden Nuclear Power Station Rural Route 11 Morris, Illinois 60450 U. S. Nuclear Regulatory Connission Resident Inspectors Office Dresden Station Rural Route 11 Morris, I 111nois 60450 Chairman Board of Supervisors of Grundy County Grundy County Courthouse Morris, Illinois 60450 Regional Administrator Nuclear Regulatory CoD111iss1on, Region III 799 Roosevelt Road, Bldg. #4 Glen Ellyn, Illinois 60137 Mr. Michael E. Parker, Chief D1~is1on of Engineering Illinois Department of Nuclear Safety 1035 Outer Park Drive, 5th Floor Spr1ngf1eld, Illinois 62704 Dresden Nuclear Power Station Un1ts 2 and 3

('.

Mr. Thomas J. Kovach Corranunwea 1th Edi son Company cc:

Mr. StEphen E. Shelton Vice President Iowa-Illincis Gas and Electric Company P. 0. Box 4350 Davenport, Iowa 52808 Michael I. Miller, Esq.

Sidley and Austin One First National Plaza Chicago~ Illinois 60603 Mr. Richard Bax Station Manager Quad Cities Nuclear Power Station 22710 206th Avenue North Cordova, Illinois 61242 Resident Inspector U. S. Nut lear RE:gulatory Convnission 2271£ 206th Avenue North Cordova, Illinois 61242 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Islar.d County Office Bldg.

Rock Island, Illinois 61201 Mr. Michael E. Parker, Chief Divisior. of Engineering I1 l i noi s Department of tluclear Safety 1035 Outer Park Drive, Springfield, Illinois 62704 Regional Administrator, Region III U. S. Nuclear Regulatory Commission 799 Roosevelt Road, Bldg. #4 Glen Ellyn, Illinois 60137 Quad Cities Nuclear Power Station Units 1 and 2