UNITED STATES NUCLEAR REGULAT-0R¥-COMMISSION WASHINGTON, D. C. 20555 Docket Nos.:

50-237/249 LSOS-85-05-017 Mr. Oennis L. Farrar Director of Nuclear Licensinq Commonwealth Edison Company

  • Post Office Box 767 Chicago, Illinois 60690

Dear Mr. Farrar:

May 16, 1985

SUBJECT:

EVALUATIONS OF COMMONWEALTH EDISON'S RESPONSE TO GENERIC LETTER 83-?.8 ITEMS 3.1.1, 3.1.2, 3.2.1, 3.2.2, AND 4.5.1 Re:

Dresden Nuclear Power Station, Unit Nos. 2 and 3 Subsequent to the anticipated transient without scram (ATWS) events at the Salem Nuclear Power Plant, the Commission reviewed intermediate term actions to be taken by licensees.

On July 8, 1983, Generic Letter (GL) 83-28, which required licensee responses to certain actions, was issued.

Commonwealth Edison Company (CECo) initially responded to GL 83-28 in a 1etter dated November 5, 1983, which was supplemented by letters dated February 29, and June 1, 1984.

The staff has reviewed CECo's responses to GL 83-28 for Items 3.1.1, 3.1.2, 3.2.1, 3.2.2, and 4.5~1. The staff's evaluation for these items is presented in the enclosed Safety Evaluation.

The staff has found CECo's responses to be adequate in these areas.

Enclosure:

  • Safety Evaluation cc w/enclosure:

See next paqe I

i

. 8505220073 8505i6

.* *n*.

,, PDR ADOCK 05000237 i* !

,

_,-_:*.*...... I.

~-

Sincerely,

~7/1%.J~

John A. Zwolinski, Chief

  • Operating Reactors Brarich #5 Division of Licensing

Docket Nos.:

50-237/249 LS05-85-U5-Ul7 Mr. Dennis L. Farrar Director of Nuclear Licensing Commonwealth Edison Company Post Office Box 767 Chicago, Illinois 60690

Dear Mr. Farrar:

  • i~ay 'i 6, 1985

SUBJECT:

EVALUATIONS OF COMMONWEALTH EDISON'S RESPONSE TO GENERIC LETTER 83-28 ITEMS 3.1.1, 3.1.2, 3.2.1, 3.2.2, AND 4.5.1 Re:

Dresden Nuclear Power Station, Unit Nos. 2 and 3 Subsequent to the anticipated transient without scram (ATWS) events at the Salem Nuclear Power Plant, the Commission reviewed intermediate term actions to be taken by licensees.

On July 8, 1983, Generic Letter (GL) 83-28, which required licensee responses to certain actions, was issued.

Commonwealth Edison Company (CECo) initially responded to GL 83-28 in a letter dated November 5, 1983, which was supplemented by letters dated February 29, and June 1, 1984.

The staff has reviewed CECo's responses to GL 83-28 fo.r Items 3.1.1, 3.1.2, 3.2.1, 3.2.2, and 4.5.1. The staff's evaluation for these items is presented in the enclosed Safety Evaluation.

The staff has found CECo's responses to be adequate in these areas.

Enclosure:

Safety Evaluation cc w/enclosure:

See next page Retyped by JBrandenburg 5/16/85.

ORB#5:DL ~ OR~~L.

CJamerson:

RGilbert.

5/lfu/85 5//ft,/85 Sincerely,.

~

a1B1Ut4 bFI John A. Zwolinski, Chief Operating Reactors Branch #5 Division of Licensing DISTRIBUTION Docket File NRC PDR Local PDR HThompson ACRS (10)

OELD BGrimes L. fintn~

-/?*YJfl/

ORB#5:DL JZwolinski 51/6185 EJordan JPartlow CJamerson RGilbert T(ETaylor, RII I JHopkins JStevens

Mr. Dennis L. Farrar cc Robert G. Fitzgibbons Jr.

Isham, Lincoln & Beale Three First National Plaza Suite 5200 Chicago, Illinois 60602 Mr. Doug Scott Plant Superintendent Dresden Nuclear Power Station Rural Route #1 Morris, Illinois 60450 U. S. Nuclear Regulatory Commission Resident Inspectors Office Dresden Station Rural Route #1 Morris, Illinois 60450 Chairman Board of Supervisors of Grundy County Grundy County Courthouse Morris, Illinois 60450

~ 2 -

U. S. Environmental Protection Agency Federal Activities Branch Region V Office ATTN:

Regional Radiation Representative 230 South Dearborn Street Chicago, Illinois 60604 James G. Keppler, Regional Administrator Nuclear Regulatory Commission, Region III 799 Roosevelt Street Glen Ellyn, Illinois 60137 Gary N. Wright, Manager Nuclear Facility Safety Illinois Department of Nuclear Safety 1035 Outer Park Drive, 5th Floor Springfield, Illinois 62704 May 16, 1985