UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION BY THE OFFICE OE NUCLEAR REACTOR REGULATION LICENSEE RESPONSE TO GENERIC LETTER 95-07.
"PRESSURE LOCKING ANP THERMAL BINDING OE SAFETY-RELATED POWER-OPERATED GATE VALVES" COMMONWEALTH EDISON COMPANY DRESPEN NUCLEAR POWER STATION. UNITS 2 ANP 3 POCKET NOS. 50-237 ANO S0-249 1.0 INTROPUCTION Pressure locking and thermal binding represent potential common-cause failure mechanisms that can render redundant safety systems incapable of performing their safety functions. The identification of susceptible valves and the determination of when the phenomena might occur requires a thorough knowledge of components, systems, and plant operations.* Pressure locking occurs in flexible-wedge and double-disk gate valves when fluid becomes pressurized inside the valve bonnet and the actuator is not capable of overcoming the additional thrust
- requirements resulting from the differential pressure created across both valve disks by the pressurized fluid in the valve bonnet. Thermal binding is generally associated with a wedge gate valve that is closed while the system is hot and then is allowed to cool before an attempt is made to open the valve.
Pressure locking or thermal binding occurs as a result of the valve design characteristics (wedge and valve body configuration, flexibility, and material thermal coefficients) when the valve is subjected to specific pressures and temperatures during various modes of plant operation. Operating experience indicates that these situations were not always considered in
. many plants as part of the design basis for valves.
2.0 REGULATORY REQUIREMENTS 10 CER Part 50 (Appendix A, General Design Criteria 1 and 4) and plant licensing safety analyses require or commit (or both) that licensees design and test safety-related components and systems to provide adequate assurance that those systems can perform their safety functions. Other individual criteria in Appendix A to 10 CER Part 50 apply to specific systems.
In accordance with those regulations and licensing commitments, and under the additional provisions of 10 CER Part 50 (Appendix B, Criterion XVI), licensees are expected to act to ensure that safety-related power-operated gate valves susceptible to pressure locking or
- th~rmal binding are capable of performing their required safety functions.
9810050279 981001 PDR ADOCK 05000237 G
- PDR
\\
fl.
- 1.
1:
ENCLOSURE On August 17, 1995, the NRC issued Generic Letter (GL) 95-07, "Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves," to request that licensees take certain actions to ensure that safety-related power-operated gate valves that are susceptible to pressure locking or thermal binding are capable of performing their safety function~ within the current licensing bases of the facility. GL 95-07 requested that each licensee, within 180 days of the date of issuance of the GL (1) evaluate the operational configurations of safety-related power-operated gate valves in its plant to identify valves that are susceptible to pressure locking or thermal binding, and (2) perform further analyses and take needed corrective actions (or justify longer schedules) to ensure that the susceptible valves, identified in (1) above, are capable of performing their intended safety functions under all modes of plant operation, including test configuration. In addition, GL 95-07 requested that licensees, within 180 days of the date of issuance of the GL, provide to the NRC a summary description of (1) the susceptibility evaluation used to determine that valves are or are not susceptible to pressure locking or thermal binding, (2) the results of the susceptibility evaluation, including a listing of the susceptible valves identified, and (3) the corrective actions, or other dispositioning, for the valves identified as susceptible to pressure locking or thermal binding. The NRC issued GL 95-07 as a "compliance backfit" pursuant to 10 CFR 50.109(a)(4)(i) because modification may be necessary to bring facilities into compliance with the rules of the Commission referenced above.
In a letter of February 13, 1996, Commonwealth Edison Company (ComEd, the licensee) submitted its 180-day response to GL 95-07 for Dresden, Units 2 and 3. The NRC staff reviewed the licensee's submittals and requested additional information (RAI) in a letter of April 2, 1996. By letter of May 24, 1996, the licensee provided the additional information. In a letter of June 5, 1996, the NRC issued a second RAI and ComEd provided the additional information by letter of July 5, 1996. By letter of May 28, 1997, the NRC issued a third RAI and in a letter of May 29; 1998, the licensee provided the additional information. The NRC staff performed an inspection to review specific aspects of information summarized in the licensee's responses to GL 95".'07. This inspection is documented in NRC Inspection Report 50-237/249-96015, date.d February 14, 1997.
3.0 STAFF EVALUATION 3.1 Scope of Licensee's Review GL 95-07 requested that licensees evaluate the operational configurations of safety-related power-operated gate valves in their plants to identify valves that are susceptible to pressure locking or thermal binding. The ComEd letters of February 13, May 24 and July 5, 1996, and May 29, 1998, described the scope of valves evaluated in response to GL 95-07. The NRC staff has reviewed the scope of the licensee's susceptibility evaluation performed in response to GL 95-07 and found it complete and acceptable.
..... 3.2 Corrective Actions GL 95-07 requested that licensees, within 180 days, perform further analyses as appropriate, and take appropriate corrective actions (or justify longer schedules), to ensure that the susceptible valves identified are capable of performing their intended safety function under all modes of plant operation, including test configuration. The licensee's submittals discussed proposed corrective actions to address potential pressure-locking and thermal-binding problems. The staffs evaluation of the licensee's actions is discussed in the following paragraphs:
- a.
The licensee stated that the following valves were modified to eliminate the potential for pressure locking:
2(3)-1402-25A/B 2(3)-1501-22A/B 2(3)-2301~8 Core Spray Inboard Injection Isolation Low Pressure Core Injection Isolation High Pressure Core Injection Isolation The staff finds that physical modification to valves. susceptible to pressure locking is an appropriate corrective action to ensure operability of the valves and is, thus, acceptable.
- b.
The licensee stated that 2(3)-1402-24A/B, Core Spray Outboard Injection, would be modified in the future when the valves are disassembled to eliminate the potential for pressure locking. These valves are normally open and are closed to perform surveillance testing. As short-term corrective action, the licensee revised procedures to declare the valves inoperable when closed for surveillance testing. The staff finds that the short-term corrective action is acceptable until the modifications to eliminate the potential for pressure locking are complete.
- c.
The licensee stated that all flexible and solid wedge gate valves in the scope of GL 95-07 were evaluated for thermal binding. When evaluating whether valves were susceptible to thermal binding, the licensee assumed that thermal binding would not occur below specific temperature thresholds. The screening criteria used by the licensee appear to provide a reasonable approach to identify those valves that might be susceptible to thermal binding.
Until more definitive industry criteria are developed, the staff concludes that the licensee's actions to address thermal binding of gate valves are acceptable.
Operating conditions for 2(3)-1301-3, Isolation Condenser Condensate Return Outboard Isolation, exceed these temperature thresholds during the performance of the 5-year isolation condenser test. The licensee stated that the procedure that performs the isolation condenser 5-year heat removal capability test was revised to cycle the valves following the test. The staff finds that the licensee's procedural change to require cycling the valves provide assurance that thermal binding conditions are adequately identified and eliminated and are, thus, acceptable.
t
4.0 CONCLUSION
On the basis of this* evaluation, the NRC staff finds that the licensee has performed appropriate evaluations of the operational configurations of safety-related power-operated gate valves to
- identify valves at Dresden, Units 2 and 3, that are susceptible to pressure locking or thermal binding. In addition, the NRC staff finds that the licensee has taken, or is scheduled to take, appropriate corrective actions to ensure that these valves are capable of performing their intended safety functions. Therefore, the staff concludes that the licensee has adequately addressed the requested actions discussed in GL 95-07.
Principal Contributor: S.Tingen, NRR Date: October f, 1 998