UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555--0001 January 5, 1996 Mr. D. L. Farrar Manager, Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 500 Downers Grove, IL 60515

SUBJECT:

RESOLUTION OF DRESDEN UNITS 2 AND 3 THIRD 10-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PIPING CLASSIFICATION OPEN ISSUE (TAC NOS. M93566 AND M93567)

Dear Mr. Farrar:

By letter dated May 19, 1994, the staff issued a safety evaluation (SE) approving Revision 2 of the Dresden Units 2 and 3 third ten-year interval lnservice Inspection (ISi) program.

In the SE, the staff noted that the licensee had taken exception to portions of lhe main steam line piping and the reactor head spray piping not being inspected in accordance with the ISi program, and requested that the licensee provide a basis for the exception.

By letter dated January 17, 1995, the licensee provided the justification for the main steam and the reactor head spray piping systems down stream of the second containment isolation valve not being classified as non-safety-related systems and as such do not meet the intent of Regulatory Guide 1.26, Quality Group Classification of Standard for Water, Steam, and Radioactive-Waste-Containing Components of Nuclear Power,elant_s.

In that Jett~r, t_he ljcensee stated that for both the main steam line piping and the head spray piping, the components beyond the second isolation valve have been classified at Dresden Units 2 and 3 as non-safety-related and as such the provisions of Regulatory Guide 1.26 do not apply to this piping. Therefore, the piping is not classified for ISi purposes and Section XI of the American Society of Mechanical Engineers (ASME) Code examination and testing is not required.

The staff has previously reviewed the classification of the above piping systems in the following documents and found that the piping down stream of the second containment isolation valve being classified as non-safety-related was acceptable:

1.

NRC letter dated December 20, 1978, approving the first ten-year ISi interval.

(/

2.

NRC letters dated March 9, 1982, and September 2, 1982, transmitting AA_}i*

SE approving Systematic Evaluation Program Topic Quality Group rl\\t:fvJ Classification of Components and Systems.

. D(~~

llC Rtit tmlS ~t 9601160397 960105

_POR AOOCK -05000237'

.'G. **

POR i v c.e,_,,,,,,...... ---- ---

3.

NRC letter dated March 5, 1985, approving the second ten-year ISI interval.

Based on the above, the staff finds that sufficient information has been provided by the licensee to support that the piping in question can be classified as non-safety-related piping, and as such, the piping is not classified for ISI purposes and the ASME Code Section XI examination and testing is not required. This completes the staff's review of the third ten-year interval ISI program open item concerning piping classification.

Sincerely, Original signed by:

John (. Stang, Senior Project Manager Project Directorate III-2

. Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation Docket Nos; 50-239, 50-249 cc:

See next page DISTRIBUTION:

Docket File PDIII-2 r/f R. Capra J. Stang ACRS,. T2E26 PUBLIC J. Roe, JWR C. Moore OGC, 015Bl8 P. Hiland, RIII DOCUMENT NAME:

DR93566.LTR

  • SEE PREVIOUS CONCURRENCE To receive a copy of this document. Indicate In the box: "C" =.Copy without res "E" = Copy with enclosures "N" = No copy OFFICE LA: PDII 1-2 PM: PDIII-2 BC:ECGB NAME GBAGCHI DATE 12,:S:A/95 12/28/95*

D. L. Farrar Co111nOnwealth Edison Company cc:

Michael I. Miller, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60603 Site Vice President Dresden Nuclear Power Station 6500 North Dresden Road Morris~ Illinois 60450-9765 Station Manager Dresden Nuclear Power Station 6500 North Dresden Road Morris, Illinois 60450-9765 U.S. Nuclear Regulatory Commission Resident Inspectors Office Dresden Station 6500 North Dresden Road Morris, Illinois 60450-9766 Regional Administrator U.S. NRC, Region III 801 Warrenville Road Lisle, Illinois 60532-4351 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety

  • 1035 Outer Park Drive
  • Springfield, Illinois 62704 Chairman Grundy County Board Administration Building 1320 Union Street Morris, Illinois 60450 Document Control Desk-Licensing Commonwealth Edison Company 1400 Opus Place, Suite 400 Downers Grove, Illinois 60515 Dresden Nuclear Power Station Unit Nos. 2 and 3