ML17179A675

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 921110-1215.Violation Noted:Mechanical Maint Individual Removed Rubber & Inner Cotton Gloves While Working in Posted Contaminated Area
ML17179A675
Person / Time
Site: Dresden  
Issue date: 12/31/1992
From: Beverly Clayton
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML17179A674 List:
References
50-237-92-32, 50-249-92-32, NUDOCS 9301120016
Download: ML17179A675 (2)


Text

J

~

j

> i l

~

Jr

-*~

NOTICE OF VIOLATION Commonwealth Edison Company*

.Dresden Station, Units 2 and 3 Docket Nos.

  • 50-237; *50-249 license Nbs. DPR-19; DPR-25 Durfog an NRC inspection conducted on November,:10.through December ~15, i992,

.. Viol at ions of.:NRC requirements *were identified> _';ln<accor.dance with *the..

"Genera] St~tement of Policy and Prbcedure fo~ NRC Enforcemeni Actions,~*

lG CFR Part 2i Appendix C, the violations are listed below:

10 CFR Part 50, Appendix 8, ~riterion XVI, states, *in part, that measures shall be established to assure that conditions adverse to quality, such as failures, malfunctions, deficiencies, deviations,.defeC:tive material and equipment, and nonconformances are promptly identified and corrected.* In the case of significant conditions adverse to quality, the *measures shall assure that the cause of the condition is determined and corrective acti.on taken to preclude repetition.

A; Contrary to the above, corrective actions to conditions adverse to quality occurring on May 9, 1992, and September 18, 1992, failures to follow radiation protection (RP) procedures bymechanical maintenance

.personnel, failed to preclude repetition of the same failure to follow procedures on December 1, 1992. Specifically:

1.

. 2.

  • On Qecember 1, 1992, tw"o mech~nical maintenance personnel tailed *.

to perform* a whole. body survey after exiting a contaminated area and prior to donning personal clothing as required by RP procedures.

On December 1, 1992,.a mech~nical mairitenanc~ individual removed the rubber and inner cotton gloves while working in a posted contaminated area;.an action prohibited by RP. procedures.

This is a Severity Level IV violation (Supplement I).*

  • B.

Contrary to the above, on November 30, 1992, a _condition adver*se to *

.quality was not *identified and corrected.* Specifically, operators continued to stroke valve 3-.1601-55 after it failed to meet its.five

  • second ~troke timl.

~hen the ~alve, after being restroked twice, met the stroke time.acceptance criteria, the surveillance was declared *

  • succes.sful
  • and no measures were taken to corr*ect the malfunction.*

This. is a Severity Level IV violation (Supplement I).

P.ursuant to the provisions of 10 CFR 2.201, Conunonwealth Edison is hereby required to submit a written statement.or explanation to the U.S. Nuclear Regulatory Conunission; ATIN:

Document C~mtrol Desk,' Washington D.C. 20555-,

with a copy to the u.s.* Nuclear Regulatory Conunission~ Region III, 799 Roosevelt Road, Glen Ellyn, Illinois, 60137, and a copy to the NRC Resident

. Inspector at the Dtesden Nuclear Station within 30 days of the date of the letter transmitting this Notice of Violation (Notice). This reply should be clearly marked-as--*a *Reply to a Notice of Violation* and should include for each violation~ (1) the reason for the ~iolation of, if contested, the basis 9301120016 921231----* ::._ ___ _,

  • .. PDR ADOCK 05000237 G

. ~DR

%~;
  • --:~~{

. ::* ~

'.ti~

. -*~.

Notice of Violation 2

for disputing the vi-0l~tion, (2) the cor~ective steps that have been taken and the results achieved, (3) the cortective steps that ~ill be taken to avoid.

, further violations, and (4) the date: when full.compliance will be achieved.

If an adequate reply is not received within the time specified*tn this *Notice, an order or a demand for information may be. issued_as to why the license

.should not be modified, suspended,- or revoked, or why such other action as may be proper should not be taken.

Where good c*ause is shown, consideration will be-giveri to extending the response tim~.

D~ted at Glen Ellyn, Illinois this li_ day of December, 1992 *

!LJ-(bt Brent Clayton, Chief Reactor Projects Branch 1

~

' l

  • ,. ~

....... ~..

  • . ~

-~~~"'

, ;:\\.

. :::._~'.-:

. *.