~g
9PII AEG(gC
gG
I
+p
~
Cy
O
C
O
0
+>>*<<"
Docket Nos.
50-387
50-388
UNITED STATES
NUCLEAR REGULATORY COMMISSION
REGION I
631 PARK AVENUE
KING OF PRUSSIA, PENNSYLVANIA 19406
OCT 20 1980
Power
8 Light Company
ATTN:
Mr. Norman
W. Curtis
Vice President
Engineering
and Construction - Nuclear
2 North Ninth Street
Allentown, Pennsylvania
18101
.Gentlemen:
Subject:
Combined Inspection 50-387/80-25
and 50-388/80-16
This refers to the routine inspection
conducted
by Mr., E.
P. Jernigan of this
office on September
17-25,
1980 at the Susquehanna
Steam Electric Station, Unit
1 and Unit 2, Berwick, Pennsylvania of activities authorized
by
NRC License
Nos.
and CPPR-102
and to, the discussions, of our findings held by Mr. Jernigan
with Mr.. P.
R. oner
and others of your staff at the conclusion of the. inspection.
Areas
examined during this inspection are described
in the Office of Inspection
and Enforcement
Inspection
Report which is enclosed with this letter .
Within
these
areas,.
the inspection consisted of selective
examinations of procedures
and representative
records,
interviews with personnel,
measurements
made
by the
inspector,
and observations
by the inspector.
Based
on the results of this inspection, it appears
that one of your activities
was not conducted
in full compliance with NRC requirements,
as set forth in the
Notice of Violation, enclosed
herewith
as Appendix A.
This item of noncompliance
has
been categorized
into the levels
as described
in our correspondence
to you
dated
December
31: 1974.
This notice is sent to you pursuant to the provisions
of Section
2.201 of the NRC's "Rules of Practice,"
Part 2, Title 10,
Code of
Federal
Regulations.
Section, 2.201 requires
you to submit to this office,
within twenty (20) days of your receipt of this notice,
a written statement or
explanation in reply including:
(1) corrective steps
which have
been taken
by
you and the results
achieved;
(2) corrective steps
which will be taken to avoid
further items of noncompliance;
and (3) the date
when full compliance will be
achieved.
In accordance
with Section 2.790 of the NRC's "Rules of Practice,"
Part 2, Title
10,
Code of Federal
Regulations,
a copy of. this letter and the enclosures will
be placed in the NRC's Public Document
Room.
If this report contains
any infor-
mation that you (or your contractor) believe to be proprietary, it is necessary
that you make
a written application within 20 days to this office to withhold
such information from public disclosure.
Any such application must be accompanied
Power
& Light Company
by an affidavit executed
by the owner of the information, which identifies the
document or part sought to be withheld, and which contains
a statement of reasons
which addresses
with specificity the items which will be considered
by the
Commission
as listed in subparagraph
(b) (4) of Section 2.790.
The information
sought to be withheld shall
be incorporated
as far as possible into a separate
part of the affidavit. If we- do not hear from you in this regard within the
specified period; the report will be placed in the Public Document
Room.
.Should. you have any questions
concerning this inspection,
we will be pleased
to
discuss
them with you.
Sincerely,
Robert T. Garison,
Chief
Reactor
Construction
and Engineering
Support Branch
Enclosures:
l.
Appendix A, Notice of Violation
~
~
~
~
~
~
~
~
2.
Combined Office of Inspection
and Enforcement
Inspection
Report
Number 50-387/80.-25
and 50-388/80-16
cc w/encl:
A. R. Sabol,
Manager,
Nuclear guality Assurance
W.
E. Barberich,
Licensing Engineer
H.
W. Keiser, Superintendent
of Plant