l1ri OAK RIDGE INSTITUTE FOR

~I SCIENCE AND EDUCATION l\ fa y 15, 20 17 l\ ls. Rach el Browder U.S. Nuclear Regulatory Commission Regio n IV 1600 East Lamar Boulevard J\rlingron, TX 7 60 11 ORISE CONTRACT NO. DE-SC0014664

SUBJECT:

LETTER REPORT FOR ANALYTICAL RESULTS FOR TWO SOIL SAMPLES ASSOCIATED WITH THE SAN ONOFRE NUCLEAR GENERATING STATION IN SAN CLEMENTE, CALIFORNIA

[INSPECTION REPORT NO. 05000361/2017-002 & 05000362/2017-002]

[DOCKET NO . 50-361 & 50-362](RFTA NO.17-001)

DCN: 5267-LR-08-0; SDG 12678-7

Dear l\Is. Browder:

The Oak Ridge Institute for Science and E ducatio n (OlUSE) is pleased to provide the enclosed da ta package for two soiJ samples received on May 4, 2017 from the San Onofre N uclea r Generating Statio n in San Clemente, California. T he samples were received in good condition. The samp les were analyzed b y gamm a spectroscop y for Cs- 137 and Co-60. The analytical data, al ong with th e procedure reference, are presented in th e attached report.

Quality Control (QC) reguirements were m et for this analysis. The QC files are available fo r your review upon reg uest.

Please feel free to con tact me at 865.576.9184 or f<orrest Smith at 865.574.9802 with any ques tions or comments.

Sincerely,

\V~~y/-1/

Ma nager Laborator y OJV\ U

\V PT:lw Enclosures E lec tronic distribution: T. Carter, N RC S. Roberts, O Rr\ U T. V itkus, OR.AU E. BaiJey, ORA U D . Hagemeyer, ORJ\U riJe code: 5267; Lab code: 12678 P.O . Box l l7 Oak Ridge, T >J 37831

  • www.orisc.ornu.gov

Gamma Spectrometry Summary Results By Analyte Report Date: May 15, 2017 Analyte: Co-60 SOP (Rev. #) CP1 (21)

Project Name: San Onofre Nuclear Generating Station Energy Signature: 1332.49 (KeV)

Project # : 201212678 SDG # : 201212678-7 Qualifier Batch Client Sample ID: Lab Sample ID: Result TPU (2s) MDC Units Flag #

A1501 303F1 LA3S1 12678S0009 -0.008 0.022 0.044 pCi/g U GS0506 L04FN DDENE 00009 12678S0009Dup 0.000 0.018 0.036 pCi/g U GS0506 A1501 303F1 LA3S1 12678S0010 -0.0037 0.0086 0.0317 pCi/g U GS0506 L04FN DDENE 00010 Electronically Validated By:

William Smith- 5/11/2017 12:22 Electronically Approved By:

Wade Ivey 5/15/2017 10:37 Qualifier Flags:

U = Analyte not detected (< MDC)

TPU = Total Propagated Uncertainty MDC = Minimum Detectable Concentration Page 1 of 1

Gamma Spectrometry Summary Results By Analyte Report Date: May 15, 2017 Analyte: Cs-137 SOP (Rev. #) CP1 (21)

Project Name: San Onofre Nuclear Generating Station Energy Signature: 661.66 (KeV)

Project # : 201212678 SDG # : 201212678-7 Qualifier Batch Client Sample ID: Lab Sample ID: Result TPU (2s) MDC Units Flag #

A1501 303F1 LA3S1 12678S0009 -0.002 0.018 0.038 pCi/g U GS0506 L04FN DDENE 00009 12678S0009Dup 0.0051 0.0085 0.0203 pCi/g U GS0506 A1501 303F1 LA3S1 12678S0010 -0.003 0.013 0.027 pCi/g U GS0506 L04FN DDENE 00010 Electronically Validated By:

William Smith- 5/11/2017 12:22 Electronically Approved By:

Wade Ivey 5/15/2017 10:37 Qualifier Flags:

U = Analyte not detected (< MDC)

TPU = Total Propagated Uncertainty MDC = Minimum Detectable Concentration Page 1 of 1