Text
t gA8 REOy
~o ce s
dsO Idt cs
~O
++*++
Mr. John H. Mueller Chief Nuclear Officer Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Operations Building, Second Floor Lycoming, NY 13093 UNITED STATES NUCLEAR REGULATORY COMIVIISSION WASHINGTON, D.C. 2055&4001 duly 23, 1998
SUBJECT:
AUTHORIZATIONTO USE ALTERNATIVESTO ASME CODE SECTION XI EXAMINATIONREQUIREMENTS FOR FOUR FLANGED, BOLTED CONNECTIONS, NINE MILE POINT NUCLEAR STATION, UNIT NO. 2 (TAC NO. MA2184)
Dear Mr. Mueller:
By letter dated June 29, 1998, Niagara Mohawk Power Corporation (NMPC or licensee) requested authorization from the NRC to use alternatives to the examination requirements of the'merican Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code),
Section XI (1989 edition) for the sixth refueling outage (RFO6) at Nine Mile Point Nuclear Station, Unit 2 (NMP2). Specifically, you proposed alternatives, pursuant to 10 CFR 50.55a(a)(3),
regarding the pressure testing acceptance criteria for flanged, bolted connections located at three m'ain steam line safety relief valves (2MSS*PSV125, 2MSS*PSV128, and 2MSS*PSV137) and one local power range monitor (LPRM 56-33).
Enclosure 1 is the NRC staffs safety evaluation for the proposed alternative examination at the connections for the three main steam line safety relief valves. is the corresponding safety evaluation for the local power range monitor connection.
As noted in these safety evaluations, the NRC staff concludes that the proposed alternatives are acceptable, inasmuch as your alternative programs provide an acceptable level of quality and safety.
Accordingly, the alternatives are authorized pursuant to 10 CFR 50.55a(a)(3)(i) for use during RFO6 and plant heatup immediately following RFO6.
During telephone discussions with the NRC staff on June 26 and 28, 1998, NMPC discussed the proposed alternatives and requested urgent NRC authorizations of the alternative examination acceptance criteria pursuant to 10 CFR 50.55a(a)(3), to support the restart of NMP2 on schedule upon completion of RFO6. At the conclusion of each of the two calls, the NRC staff provided verbal authorization for use of the proposed aitematives, subject to NMPC's expedited submittal fjt=zt~
of written requests for authorization, which you subsequently provided by your letter of June 29, ~ ~
1998. The NRC staff finds your written request to be consistent with the previous telephone discussions upon which the NRC based its verbal authorizations.
Accordingly, this letter reaffirms our previous authorizations to use alternatives to ASME Code Section XI examination requirements during RFO6 and the subsequent plant heatup for the four bolted, flanged connections.
9807280353 980723 PDR ADOCK 050004i0 PDR
July 23, 1998 J. H. Mueller Ifyou have any questions regarding this matter, please contact Mr. Darl Hood by phone at (301) 415-3049 or by electronic mail at dsh@nrc.gov.
Sincerely, Original Signed by:
S. Singh Bajwa, Director Project Directorate l-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation I
Docket No. 50-410
Enclosures:
- 1. Safety Evaluation for Three Main Steam Safety Valve Connections
- 2. Safety Evaluation for Local Power Range Monitor Connection ccw/encis:
See next page Distribution:
~
/Docket File PUBLIC-PDI-1 Reading OGC ACRS LDoerflein, RGN-I DHood SBajwa TMcLellan GBagchi GGeorgiev DOCUMENT NAME: G:>NMP2iNM2A2184.LTR
- See previous concurrence To receive e copy of this document. indicete in the box: "C" ~ Copy without enclosures "E" ~ Copy with enciosures "N" ~ No copy OFFICE PH: PDI-1 NAME DHOod/1CC DATE 07/
/98 LA:PDI-1 SLittl 07
/98 D:PDI-1 SBajwa yn'7/
98 OFFICIALRECORD COPY BC:ECGB*
GBagchi 07/15/98 OGC*
MYoung 07/17/98 4
cr "V V 4>v V
duly 23, 1998 J. H. Mueller Ifyou have any questions regarding this matter, please contact Mr. Darl Hood by phone at (301) 415-3049 or by electronic mail at dsh@nrc.gov.
Sincerely, Original Signed by:
S. Singh Bajwa, Director Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket No. 50-410
Enclosures:
- 1. Safety Evaluation for Three Main Steam Safety Valve Connections
- 2. Safety Evaluation for Local Power Range Monitor Connection ccw/encls:
See next page Distribution:
Docket File PUBLIC PDI-1 Reading OGC ACRS LDoerflein, RGN-I DHood SBajwa TMcLellan GBagchi GGeorgiev DOCUMENT NAME: G:>NMP2tiNM2A2184.LTR
- See previous concurrence To receive e copy of this document, indicete in the box: "C" a Copy without enclosures "E" a Copy with enclosures "N" ~ No copy OFFICE PH: PDI-1 WANE DHood/lcc DATE 07/
/98 LA:PDI-1 SLittl 07
/98 D: PDI-1 SBajwa yn'7/
98 OFFICIALRECORD COPY BC:ECGB*
GBagchi 07/15/98 OGC*
MYoung 07/17/98
J. H. Mueller Ifyou have any questions regarding this matter, please, contact Mr. Darl Hood by phone at (301) 415-3049 or by electronic mail at dsh@nrc.gov.
Sincerely, S. Si gh Bajwa, Director Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket No. 50-410
Enclosures:
- 1. Safety Evaluation for Three Main Steam Safety Valve Connections
- 2. Safety Evaluation for Local Power Range Monitor Connection cc w/encis:
See next page
John H. Mueller Niagara Mohawk Power Corporation CC:
Regional Administrator, Region I
U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector Nine Mile Point Nuclear Station P.O. Box 126 Lycoming, NY 13093 Mr. Jim Rettberg NY State Electric 8 Gas Corporation Corporate Drive Kirkwood Industrial Park P.O. Box 5224 Binghamton, NY 13902-5224 Mr. John V. Vinquist, MATS Inc.
P.O. Box 63 Lycoming, NY 13093 Supervisor Town of Scriba Route 8, Box 382 Oswego, NY 13126 Mr. Richard Goldsmith Syracuse University College of Law E.l. White Hall Campus
- Syracuse, NY 12223 Nine Mile Point Nuclear Station Unit No. 2 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. Timothy S. Carey Chair and Executive Director State Consumer Protection Board 5 Empire State Plaza, Suite 2101 Albany, NY 12223 Mark J. Wetterhahn, Esquire Winston 8 Strawn 1400 L Street, NW.
Washington, DC 20005-3502 Gaty D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
- Syracuse, NY 13202 Mr. F. William Valentino, President New York State Energy, Research, and Development Authority Corporate Plaza West 286 Washington Avenue Extension Albany, NY 12203-6399