ML17059B591

From kanterella
Jump to navigation Jump to search
Forwards Final Rept of Metallurgical Evaluation of Failed Shroud Tie Rod Lower Spring Contact Wedge Latches. Exams Confirmed That Latch Failure Was Caused by High Stress That Resulted in Intergranular Stress Corrosion Cracking
Date released: 06/30/2017 Download: ML17059B591


Forwards Final Rept of Metallurgical Evaluation of Failed Shroud Tie Rod Lower Spring Contact Wedge Latches. Exams Confirmed That Latch Failure Was Caused by High Stress That Resulted in Intergranular Stress Corrosion Cracking
ML18040A263
Person / Time
Site: Nine Mile Point 
Issue date: 06/13/1997
From: Abbott R
NIAGARA MOHAWK POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML18040A263 (7)
Rev 0 to Metallurgical Evaluation of Failed Shroud Tie Rod Lower Spring Contact Wedge Latches, for June 1997
ML17059B590
Person / Time
Site: Nine Mile Point 
Issue date: 06/30/1997
From: Delwiche D, Horn R, Rodabaugh J
NIAGARA MOHAWK POWER CORP.
To:
References
Download: ML17059B590 (140)