Forwards Safety Evaluation of 800708,1110,820614,830624 & 840621 Responses to IE Bulletin 80-11, Masonry Wall Design. Use of leak-before-break Concept Under Consideration for Rulemaking.Responses Otherwise Acceptable
ML17058A518
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 03/13/1986
From: Zwolinski J
Office of Nuclear Reactor Regulation
To: Mangan C
NIAGARA MOHAWK POWER CORP.
Shared Package
ML17058A519 List:
References
IEB-80-11, IEB-80-1122, TAC-42884, NUDOCS 8603240122
Download: ML17058A518 (6)


Text

Docket No. 50-220 MAR 13 )gsg Niagara Mohawk Power Corporation Attn:

Mr. C.

V. Mangan Senior Vice President c/o Miss Catherine R. Seibert 300 Erie Boulevard West

Syracuse, New York 13202

Dear Mr. Mangan:

SUBJECT:

SAFETY EVALUATION -

MASONRY WALL DESIGN, IE BULLETIN 80-11 (TAC 42884)

Re:

Nine Mile Point Nuclear Station, Unit No.

1 We have completed our review of your response to IE Bulletin 80-11, Masonry Wall Design, for Nine Mile Point Unit 1, as submitted in letters dated July 8,

1980, November 10,
1980, June 14,
1982, June 24,
1983, and June 21, 1984.

Your use of the "leak-before-break" concept to eliminate consideration of the pressure loads resulting from a high energy line break is under review as a rule-making issue.

However, the generic structural engineering review of the Masonry Wall Design for Nine Mile Point 1 is complete.

The enclosed Safety Evaluation supporting our findings is enclosed.

Sincerelv, 8+P3QQOK22 50002PO 603l>

PDR P,QOCK 0

>DR 8

Enclosure:

Safety Evaluation cc w/enclosure:

See next page DISTRIBUTION John A. Zwolinski, Director BWR Proiect Directorate ¹1 Division of BWR Licensing NRC POR Local PDR BWD¹1 Reading RBernero OELD EJordan BGrimes JPartlow JKelly CJamerson JZwolinski ACRS (10)

NChokshi GHolahan DBL:PD¹1 CJamerson 3/>3/86 DBL PD¹1 J}(

JKelly:tm 3 / Q/86 DBL:PD¹1 JZwolinski g /)p/86

/

I H

N ll

/L gW'4 "<CIJ~

~

~CV P

+

0 e jg UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 March 13, 1986 Docket No. 50-220 Niagara Mohawk Power Corporation Attn:

Mr. C.

V. Mangan Senior Vice President c/o Miss Catherine R. Seibert 300 Erie Boulevard West

Syracuse, New York '3202

Dear Mr. Mangan:

SUBJECT:

SAFETY EVALUATION - MASONRY WALL DESIGN, IE BULLETIN 80-11 (TAC 42884}

Re:

Nine Mile Point Nuclear Station, Unit No.

1 We have completed our review of your response to IE Bulletin 80-11, Masonry Wall Design, for Nine Mile Point Unit 1, as submitted in letters dated Julv 8,

1980, November 10,
1980, June 14,
1982, June 24,
1983, and June 21, 1984.

Your use of the "leak-before-break" concept to eliminate consideration of the pressure loads resulting from a high energy line break is under review as a rule-making issue.

However, the generic structural engineering review of the Masonry llall Design for Nine Mile Point 1 is complete.

The enclosed Safety Evaluation supporting our findings is enclosed.

Sincerely, John

. 7wolinski, Director BWR Proiect Directorate 81 Division of BWR Licensino

Enclosure:

Safety Evaluation cc w/enclosure:

See next oage

Mr. C. V. Mangan Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station, Unit No.

1 CC:

Troy B. Conner, Jr., Esquire Conner 5 Wetterhahn Suite 1050 1747 Pennsylvania

Avenue, N.

W.

Washington, D.

C.

20006 Frank R. Church, Supervisor Town of Scriba R.

D. ¹2

Oswego, New York 13126 Niagara Mohawk Power Corporation ATTN:

Mr. Thomas Perkins Plant Superintendent Nine Mile Point Nuclear Station Post Office Box 32

Lycominq, New York 13093 Resident Inspector U. S. Nuclear Reaulatory Commission Post Office Box 126
Lycomino, New York 13093 John W. Keib, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, New York 13202 Rdgional Administrator, Reqion I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Mr. Jay Dunkleberger Division of Policy Analysis and Planning New York State Energy Office Agency Building 2 Empire State Plaza
Albany, New York 12223