UNITED STATES NUCLEAR R EG ULATORY COMMISS ION WASHINGTON, D. C. 20555 NIAGARA MOHAWK POWER CORPORATION DOCKET NO. 50-220 NINE MILE POINT NUCLEAR STATION UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. >>2 License No.

DPR-63 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Niagara Mohawk Power Corporation (the licensee) dated March 16,

1989, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No.

DPR-63 is hereby amended to read as follows:

8912140332 891201 PDR ADQCK 05000220 P

PNU

f (2)

Technical S ecifications The Techni ca 1 Speci ficati ons conta ined in Appendi ces A and 8, as revised through Amendment No.llz

, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Q Robert A. Capra, Director

'$'roject Directorate I-l Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

December 1,

1989

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO.

112 TO FACILITY OPERATING LICENSE NO. DPR-63 DOCKET NO. 50-220 Revise Appendix A as follows:

Remove Pa e

148 Insert Pa e

148

0 I

Line or System LIMI1 ING CONDI T ION f OR Of'ERAT ION Table 3.3.4 (Continued)

PRIMARy CONTAINMENT ISOLATION VAl.VES LINES ENTERING FREE SPACE OT'HE CONTAINHENT Location Relative Maximum Action on Ini t lat ing Signal No. of Valves to Primary Normal Oper.

Time Initiating (All Valves Have (Each Line)

Containment Position Motive Po~er (Sec)

~SI nal Remote Hanual Backu

)

Core Spra~ (c)

Pump Sultion (Four Linis from Suppression Chamber)

Outside Open AC Hotor 90 Remote manual Pump Discharge (Two Test Lines to Suppression Chamber)

I Outside Closed AC Hotor LINES HITH A CLOSED 1.00P INSIDE CONTAINHENT VESSELS 90 Reactor water level Close low-low Recir.

Pump C<>o~lin Water Su~I (c)

Supply Line Return l.ine Outside Outside Open Self Act. Ck.

Open DC Hotor 30 Remote manual

~Dr well Cooler Water Supp~i (c)

Supply Line Return Line Outside Outside Open Open Self Act. Ck.

DC Motor 30 Remote manual LINES WITH A CLOSED LOOP OUTSIDE CONTAINHENT VESSELS Containment Spray (c)

Or~well I Suppression Chamber Coaaen Supply (Four l.ines)

I)rywell Branch (Four Lines)

Suppression Chamber Branch (One Branch for Each System)

Pump Suction From Su~pression Chamber (Four Lines)

Outside Outside Outside Outside Open Air/DC Sol.

Self Act. Ck.

Self Act. Ck.

Open AC Hotor 60

/0 Remote manual Remote manual One valve in earh separate line and one valve in each common line.

(c) Ihese are r.lassified as not-testable valves and penetrations.

148 Amendment No.

112