ML17055E297
| ML17055E297 | |
| Person / Time | |
|---|---|
| Site: | Nine Mile Point |
| Issue date: | 10/27/1988 |
| From: | Wenzinger E NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Mangan C NIAGARA MOHAWK POWER CORP. |
| Shared Package | |
| ML17055E298 | List: |
| References | |
| NUDOCS 8811090153 | |
| Download: ML17055E297 (6) | |
See also: IR 05000220/1988018
Text
J
gC CP~RAYED
3387RIBUTION
DKMONSTRA,'EON
-
SYSTEM
t
i~
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
CESSION NBR:8811090153
DOC.DATE: 88/10/27
NOTARIZED: NO
FACIL:50-220 Nine Mile Point Nuclear Station, Unit 1, Niagara
Powe
50-410 Nine Mile Point Nuclear Station, Unit 2, Niagara
Moha
AUTH.NAME
AUTHOR AFFILIATION
WENZINGER,"E.C.
Region
1, Ofc of the Director
RECIP.NAME
RECIPIENT AFFILIATION
MANGAN,C.V.
Niagara
Mohawk Power Corp.
SUBJECT:
Forwards Insp Repts 50-220/88-18
& 50-410/88-18
on
880825-1003
DISTRIBUTION CODE:
IE01D
COPIES
RECEIVED:LTR
ENCL
SIZE:
TITLE: General
(50 Dkt)-Insp Rept/Notice of Violation Response
NOTES:
DOCKET
05000220
05000410
RECIPIENT
ID CODE/NAME
PD1-1
BENEDICT,R
INTERNAL: ACRS
DEDRO
NRR/DLPQ/PEB
11
NRR/DOEA DIR 11
NRR/DREP/RPB
10
NRR/PMAS/ILRB12
OE L
ERMAN,J
ILE
02
EXTERNAL: LPDR
COPIES
LTTR ENCL
1
1
l.
1
2
2
1
1
1
1
1
1
2
2
1
1
1 '
1
1
1
1
1
1
RECIPIENT
ID CODE/NAME
HAUGHEY,M
NRR MORISSEAU,D
NRR/DLPQ/QAB 10
NRR/DREP/EPB
10
NRR/DRIS DIR 9A
NUDOCS-ABSTRACT
OGC/HDS1
RGN1
FILE
01
NRC PDR
RESL MARTIN,D
COPIES
LTTR ENCL
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
D
I
D
NVZE IO ALL "RIDS" RECIPIENIS:
h
D
D
PLEASE HELP US 'ZO REDUCE HASTE!
CXRKACT 'lHE DOCUMEFZ CONTROL DESK
RCjOM Pl-37
(EXT. 20079)
1Q ELOCUTE KÃlR NAME FROM DISTRXM7ZIGN
LISTS H)R DOClIMEÃIS YOU DON'T NEED)
TOTAL NUMBER OF COPIES
REQUIRED:
LTTR
25
ENCL
25
p
0
Docket No. 50-220
Docket No. 50-410
27 OCT 1888
Niagara
Mohawk Power Corporation
ATTN:
Mr. Charles
V. Mangan
Senior Vice President - Nuclear
301 Plainfield Road
Syracuse,
13212
Gentlemen:
Subject:
Inspection
Report
No. 50-220/88-18
and 50-410/88-18
This letter transmits
the results of the routine inspection
conducted
by
Mr. W. Cook,
and others of this office on August 25 through October 3,
1988 at
Nine Mile Point, Units
1 and 2, Scriba,
A summary of the findings was
presented
to Mr. J . Willis and other
members of your staff at the conclusion of
the inspection.
Based
upon the inspectors'eview,
two activities at Unit 2 were not conducted
in compliance with your own procedures
and
NRC regulations.
One violation
involves failure to follow a station surveillance
procedure
and
a second
violation involves the failure to take prompt and effective corrective action
for an identified deficiency involving an inaccurate list of snubbers.-
The',
failure to -follow the surveillance
procedure,
the
second
example in rec'ent".,',- -'-
months, points to
a need
by your staff to place
more emphasis
on procedural
compliance
and supervisory oversight of ongoing testing.
The failure to take
timely corrective action
has
been
a problem previously addressed
with you and
your staff and is of particular concern to us.
In addition,
although not
included in the Notice of Violation, inspector
review of post accident
sampling
system capability found your actions to be inadequate
(see
folio'wup to Item
No. 410/87-22-10).
These violations have
been categorized
by severity level according to
10 CFR Part 2, Appendix C (Enforcement Policy).
You are required to respond to these
violations and in preparing your response
you should follow the instructions
in Appendix A.
The response
required
by this letter is not subject to the clearance
procedures
of the Office of Management
and Budget
as required
by the Paperwork
Reduction Act of 1980,
PL 96-511.
-:1 1090153
g"-l1 0~7
ADOCK 05000220
OFFICIAL RECORD
COPY
CIR
NMP 88"18
0001.0.0
-
Niagara
Mohawk Power Corporation
27 OCT
1SBB
We appreciate
your cooperation
in these matters.
Sincerely,
Edward
C. Wenzinger,
Chief
Projects
Branch
No.
2
Division of Reactor Projects
Enclosures:
l. Appendix A, Notice of Violation
2.
NRC Region I, Combined Inspection
Report
No. 50-220/88-18
and 50-410/88-18
cc w/encls:
Connor
8 Wetterhahn
John
W. Keib, Esquire
T. Perkins,
Vice President,
Nuclear Generation
J. Willis, Station Superintendent
K. Dahlberg, Unit
1 Superintendent
R. Abbott, Unit 2 Superintendent
R. Randall, Unit
1 Superintendent
of Operations
R. Smith, Unit 2 Superintendent
of Operations
Vice President,
Quality Assurance
C.
Beckham,
Manager Nuclear Quality Assurance
Operations
W. Hansen,
Manager Corporate Quality Assurance
Troy B. Conner, Jr.,
Esquire
Director,
Power Division
Department of Public Service,
State of New York
New York State,
Department of Law
Public Document
Room (PDR)
Local Public Document
Room (LPDR)
Nuclear Safety Information Center
(NSIC)
NRC Resident
Inspector
State of New York
bcc w/encls:
Region I Docket
Room (with concurrences)
Management Assistant,
DRMA (w/o encls)
J.
Johnson,
Section Chief,
M. Haughey,
Licensing Project Manager,
Unit
1 and
2
State
Liaison Officer (SLO)
B. Clayton,
EDO,
Region I Coordinator
P. Koltay, SRI,
IP3
f
A. Luptak, SRI, FitzPatrick
RI:DRP
Banerjee/rhl
10/~'88
r
RI
RI
Johnson
.f We zinger
10/Rl /88
10/ .I88
OFFICIAL RECORD
COPV
CIR NMP 88-18 - 0001.1.0
10/21/88