Grants Relief for Use of ASME Code Case N-415 for Inservice Testing Program,Per Util 880108 Request.Code Case Will Be Used for Testing Relief Valves,Safety Values & Rupture Discs in Pump & Valve Testing Program
ML17055D782
Person / Time
Site: Nine Mile Point 
Issue date: 04/14/1988
From: Capra R
Office of Nuclear Reactor Regulation
To: Mangan C
NIAGARA MOHAWK POWER CORP.
References
TAC-67172, NUDOCS 8804220014
Download: ML17055D782 (8)


Text

April 14, 1988 Docket No. 50-410 Mr. Charles V. Mangan Senior Vice President Niagara Mohawk Power Corporation 301 Plainfield Road

Syracuse, New York 13212

Dear Mr. Mangan:

DISTRIBUTION= MC-WF NRCPDR JPartlow PDI-1 Rdg.

JJohnson,RI SVarga ACRS(10)

BBoger Local PDR CVogan EJordan MKaughey

SUBJECT:

USE OF ASME CODE CASE N-415 FOR THE INSERVICE TESTING (IST)

PROGRAM AT NINE MILE POINT UNIT 2 (TAC 67172)

By letter dated January 8, 1988, the Niagara Mohawk Power Corporation requested permission to use the ASME Boiler and Pressure Vessel Code Section XI Code Case N-415 in the Nine Mile Point Unit 2 (NMP-2) Inservice Testing Program.

Code Case N-415, "Alternative Rules for Testing Pressure Relief Devices," will be used for testing relief valves, safety values and rupture discs in the pump and valve testing program.

Code Case N-415 allows the use of the testing requirements of ANSI/ASME Standard OM-1-1981 as an alternative to the requirements of Subsection

IWV,Section XI, Division 1 of the ASME Boiler and Pressure Vessel Code.

As indicated in the footnotes to 10 CFR 50.55a, the use of certain Code cases may be authorized pursuant to 50.55a(a)(3).'0 CFR 50.55a(a)(3)(i) permits licensees to propose alternatives to the regulatory requirements when the licensee can demonstrate that the proposed alternative would provide an acceptable level of quality and safety.

Code Case N-415, was incorporated in Revision 5 of Regulatory Guide (RG) 1.147.

Incorporation into this RG indicates that following the requirements of the Code Case would provide an acceptable level of quality and safety for the testing of safety related pressure relief devices.

The RG endorsement does not contain any reservation; therefore, the Code Case is acceptable for the intended use without any restrictions in operating plants.

On the basis of the above discussion and pursuant to 10 CFR 50.55a(a)(3)(i) the staff finds that the use of Code Case N-415 at Nine Mile Point, Unit 2

1) as endorsed by RG 1.147 provides an acceptable level of quality and safety, and 2) is authorized by law and will not endanger life or property or the common defense and security and is otherwise in the public interest.

Relief is hereby granted for the use of Code Case N-415 at Nine Mile Point Unit 2.

Sincerely, 88042200i4 8804i4 PDR ADQCK 050004i0 P

PDR t

cc:

See next page Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects, I/II

  • SEE PREVIOUS CONCURRENCE PDI 1

q PDI 1

CVogan* ~g~b MHaughey*:mak 4/04/88 $~

4/04/88 OGC-WF MYoung*

4/04/88 PDI-1 RCapra 4/tg /88

4p P

v I

~

I ~

f II II 4

I II a x pr

~

P l

Docket No. 50-410 Mr. Charles V. Mangan Senior Vice President Niagara Mohawk Power Corporation 301 Plainfield Road

Syracuse, New York 13212

Dear Mr. Mangan:

DISTRIBUTION ocet i e NRCPDR PDI-1 Rdg.

SVarga BBoger CVogan MHaughey OGC-WF JPartlow JJohnson,RI ACRS(10)

Local PDR EJordan

SUBJECT:

USE OF ASME CODE CASE N-415 FOR THE INSERVICE TESTING (IST)

PROGRAM AT NINE MILE POINT UNIT 2 (TAC 67172)

By letter dated January 8, 1988, the Niagara Mohawk Power Corporation requested permission to use the ASME Boiler and Pressure Vessel Code Section XI Code Case N-415 in the Nine Mile Point Unit 2 (NMP-2) Inservice Testing Program.

Code Case N-415, "Alternative Rules for Testing Pressure Relief Devices," will be used for testing relief valves, safety values and rupture discs in the pump and valve testing program.

Code Case N-415 allows the use of the testing requirements of ANSI/ASME Standard OM-1-1981 as an alter native to the requirements of Subsection

IWV,Section XI, Division 1 of the ASME Boiler and Pressure Vessel Code.

As indicated in the footnotes to 10 CFR 50.55a, the use of certain Code cases may be authorized pursuant to 50.55(a)(3).

10 CFR 50.55a(a)(3)(i) permits licensees to propose alternatives to the regulatory requirements when the licensee can demonstrate that the proposed alternative would provide an acceptable level of quality and safety.

Code Case N-415, was incorporated in Revision 5 of Regulatory Guide (RG) 1. 147.

Incorporation into this RG indicates that following the requirements of the Code Case would provide an acceptable level of quality and safety for the testing of safety related pressure relief devices.

The RG endorsement does,not contain any reservation; therefore, the Code Case is acceptable for the intended use without any restrictions in operating plants.

On the basis of the above discussion and pursuant to 10 CFR 50.55a(a)(3)(i) the staff finds that the use of Code Case N-415 at Nine Mile Point, Unit 2

1) as endorsed by RG 1. 147 provides an acceptable level of quality and safety, and 2) is authorized by law and will not endanger life or property or the common defense and security and is otherwise in the public interest.

Relief is hereby granted for the use of Code Case N-415 at Nine Mile Point Unit 2.

Sincerely, cc:

See next page Robert A. Capra, Director Project Director ate I-l Division of Reactor Projects, I/II

  • SEE PREVIOUS CONCURRENCE PDI-1 CVogan* g g+

4/04/88 pi~

PDI-1 MHaughey*:mak 4/04/88 OGC-WF MYoung*

4/04/88 PDI-1 RCapra 4/

/88

1

Docket No. 50-410 Mr. Charles V. Mangan Senior Vice President Niagara Mohawk Power Corporation 301 Plainfield Road

Syracuse, New York 13212 DISTRIBUTION Doc et i e NRCPDR Local PDR PDI-1 Rdg.

SVarga BBoger CVogan MHaughey OGC-MF JPartlow EJordan JJohnson,RI ACRS(10)

Dear Mr. Mangan:

SUBJECT:

USE OF ASME CODE CASE N-415 FOR THE INSERVICE TESTING (IST)

PROGRAM AT NINE MILE POINT UNIT 2 (TAC 67172)

By letter dated January 8, 1988, the Niagara Mohawk Power Corporation requested permission to use the ASME Boiler and Pressure Vessel Code Section XI Code Case N-415 in the Nine Mile Point Unit 2 (NMP-2) Inservice Testing Program for the testing of pressure relief valves and safety relief valves.

10 CFR 50.55a(a)(3)(i) permits licensees to propose alternatives to the regulatory requirements when the licensee can demonstrate that the proposed alternative would provide an acceptable level of quality and safety.

Code Case N-415, "Alternative Rules for Testing Pressure Relief Devices" was incorporated in Revision 5 of Regulatory Guide (RG)

1. 147.

Incorporation into this RG indicates that following the requirements of the Code Case would provide an acceptable level of quality and safety for the testing of safety related pressure relief devices.

The RG endorsement did not contain any reservation; therefore, the Code Case is acceptable for the intended use without any restrictions in operating plants.

On the basis of the above discussion and pursuant to 10 CFR 50.55a(a)(3)(i) the staff finds that the use of Code Case N-409 at Nine Mile Point, Unit 2

1) as endorsed by RG 1. 147 provides an acceptable level of quality and safety, and 2) is authorized by law and will not endanger life or property or the common defense and security and is otherwise in the public interest.

Relief is hereby granted for the use of Code Case N-415 at Nine Mile Point Unit 2.

Sincerely, cc:

See next page Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects, I/II PDI-1 CVogan 3/23/88 MHaughey:mak 0

C-WF

/

/88)

PDI-1 RCapra 3/4 /88

~ I ~

i I

r I II ff p

r P,

lftr~>'l dd h>

4) h hd v

rr t

Ir dd I, h

~>>

+ ~

4

,fp hf I~

, 9>>dr c.

d hd I >>

d I "I dl-I p'

~'f I I.>>

'd

~

P h

,[

nd Pt

'I pq

~

peart ', hrdy+

>ty pt>> j>>

)

Il i "lip p

24, l

t 4

dpt I cd d

4 d,hg/

hl i

d,

'I'", )ft>

d ><

I "h>

I

'I dd II yrg d

d'I> ~

4 II I

d,'>

g

~ f r'dr I

> 4I d

2' tt t

~

Mr. C. V. Mangan Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Unit 2 CC:

Mr. Troy B. Conner, Jr.,

Esq.

Conner 5 Wetterhahn Suite 1050 1747 Pennsylvania

Avenue, N.W.

Washington, D.C.

20006 Mr. Richard Goldsmith Syracuse University College of Law E. I. White Hall Campus

Syracuse, New York 12223 Mr. Don Hill Niagara Mohawk Power Corporation Suite 550 4520 East West Highway
Bethesda, MD 20814 Resident Inspector Nine Mile Point Nucleat Power Station P. 0.

Box 99

Lycoming, New York 13093 Mr. Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, New York 13202 Mr. Peter E. Francisco, Licensing Niagara Mohawk Power Corporation 301 Plainfield Road
Syracuse, New York 13212 Regional Administrator, Region I U.S. Nuclear Regulatory Coamission 475 Allendale Road King of Prussia, Pennsylvania 19406 Mr. Paul D.

Eddy New York State Public Serice Comoission Nine Mile Point Nuclear Station-Unit 2 P.O.

Box 63

Lycoming, New York 13093 Mr. Richard M. Kessel Chair and Executive Director State Consumer Protection Board 99 Washington Avenue
Albany, New York 12210 Mr. Richard Abbott, Unit 2 Station Superintendent Nine Mile Point Nuclear Station Niagara Mohawk Power Corporation P. 0.

Box 32

Lycoming, NY 13093 Mr. Thomas Perkins, General Supt.

Nine Mile Point Nuclear Station Niagara Mohawk Power Corporation P. 0.

Box 32

Lycoming, NY 13093 Ms.

Donna Ross New York State Energy Office 2 Empire State Plaza 16th Floor

Albany, New York 12223

.a W