Advises That ASME Code Cases N-278 & N-375-2 to Be Used in Inservice Insp Program Acceptable & Per Reg Guide 1.47,use Provides Acceptable Level of Quality & Safety & Will Not Endanger Life or Property or Common Defense & Security
ML17055D687
Person / Time
Site: Nine Mile Point 
Issue date: 03/15/1988
From: Capra R
Office of Nuclear Reactor Regulation
To: Mangan C
NIAGARA MOHAWK POWER CORP.
References
RTR-REGGD-01.047, RTR-REGGD-1.047 TAC-67415, NUDOCS 8803210524
Download: ML17055D687 (8)


Text

March 15, 1988 Docket No. 50-220 Mr. Charles V. Mangan Senior Vice President Niagara Mohawk Power Corporation 301 Plainfield Road

Syracuse, New York 13212

Dear Mr. Mangan:

DISTRIBUTION (NRCPDR Local PDR PDI-1 Rdg.

TMurley/JSniezek FMiraglia CRossi SVarga BBoger ARM/LFMB HBClayton,EDO CVogan RBenedict DNeighbors OGC EJordan JPartlow TBarnhart(4)

ACRS(10)

GPA/PA JJohnson,RI EMTB By letter dated October 23, 1987 you requested NRC approval to use ASME Code Cases N-278 and N-375-2 in the Nine Mile Point Station, Unit No.

1 Inservice Inspection Program (TAC 67415).

The Code Cases will be used for the following applications:

N-278 "Alternative Ultrasonic Calibration Block Configuration, I-3131 and T-434.3."

This code case will be used for the procurement of a new reactor pressure vessel calibration standard.

N-375-2 "Rules for Ultrasonic Examination of Bolts and Studs."

This code case will be used for the procurement of a new reactor vessel closure stud calibration standard and for the examination of the vessel studs.

Your request was in accordance with 10 CFR 50.55a(a)(3) which permits alternatives to the ASME Code if the proposed alternatives would provide an acceptable level of quality and safety.

He have reviewed your request that the above Code Cases be used for the stated applications.

Regulatory Guide 1.147, Revision 5, "Inservice Inspection Code Case Acceptability ASME Section XI Division I," dated August 1986, lists code cases that are generally 'acceptable to the NRC staff for implementation in the inservice inspection of, light-water cooled nuclear power plants.

Both of these Code Cases are listed by Regulatory Guide 1.147 as being acceptable to the NRC staff.

Code Case N-375-2 is endorsed by Regulatory Guide 1. 147 with no exceptions by the NRC staff.

Code Case N-278 is acceptable subject to conditions as stated in Regulatory Guide 1. 147.

The use of this Code Case requires that the additional conditions be met.

Ll L f'l IIII A C

II' 4

i i

4 I

1 II

'l L

J

We find that the uses of these Code Cases are acceptable and, pursuant to 10 CFR 50.55a(a)(3) that their use:

1) as endorsed by Reg.

Guide 1.147, provides an acceptable level of quality and safety, and 2) is authorized by law and will not endanger life or property or the common defense and security and is otherwise in the public interest.

Sincerely, cc:

See next page Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects, I/II

  • SEE PREVIOUS CONCURRENCE PDI-1 P DI-1 CVogan*

DNeighbors*:mak 3/07/88 3/07/88 PDI-1 RB ne icg SS EMTB*

3/07/88 OGC NYoung*

3/08/88

~C PDI-1 RCapra 3/g /88

'L, J

h Me find that the uses of these Code Cases are acceptable and find that their use pursuant to 10 CFR 50.55a(a)(3):

1) provides an acceptable level of quality and safety, and 2) is authorized by law and will not endanger life or property or the common defense and security and is otherwise in the public interest.

Sincerely, Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects, I/II cc:

See next page PDI-1 ~

CVo an 3/

/88 p

D ghbors:mak 3

/88 EMTB 3/7/

8 RCapra 3/$ /88 3/

/88

rl t

L ~

"tJ I

ll

Mr. C. V. Mangan Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station, Unit No.

1 CC:

Troy B. Conner, Jr.,

Esquire Conner 5 Wetterhahn Suite 1050 1747 Pennsylvania

Avenue, N.

W.

Washington, D. C.

20006 Frank R. Church, Supervisor Town of Scriba R.

D.

F.2

Oswego, New York 13126 Hr. Thomas Perkins General Supt.-Nuclear Generation Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Post Office Box 32
Lycoming, New York 13093 Resident Inspector U. S. Nuclear Regulatory Commission Post Office Box 126
Lycoming, New York 13093 Mr. Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, New York 13202 Regional Administrator, Region I U. S. Nuclear Regulatory Conmission 475 Allendale Road King of Prussia, Pennsylvania 19406 Ms.

Donna Ross New York State Energy Office 2 Empire State Plaza 16th Floor

Albany, New York 12223 Mr. Thomas W.

Roman Unit 1 Station Superintendent Nine Mile Point Nuclear Station Post Office Box 3P

Lycoming, New York 13093

V

~ e l.

a t'