Responds to 871207 Request for Relief from Section XI of ASME Boiler & Pressure Vessel Code Re Performance of Sys Leakage Test of Rcpb.Sufficient Basis to Show Impracticality Not Provided.Request for Relief Denied
ML17055D681
Person / Time
Site: Nine Mile Point 
Issue date: 03/15/1988
From: Capra R
Office of Nuclear Reactor Regulation
To: Mangan C
NIAGARA MOHAWK POWER CORP.
References
TAC-67417, NUDOCS 8803210262
Download: ML17055D681 (6)


Text

March 15, 1988 Docket No. 50-220 Mr. Charles V. Mangan Senior Vice President Niagara Mohawk Power Corporation 301 Plainfield Road

Syracuse, New York 13212

Dear Mr. Mangan:

DISTRIBUTION NRCPDR Local PDR PDI-1 Rdg.

TMurley/JSniezek FMiraglia CRossi SVarga BBoger ARM/LFMB HBClayton,EDO CVogan RBenedict DNeighbors OGC EJordan JPartlow TBarnhart(4)

ACRS(10)

GPA/PA JJohnson,RI By letter dated December 7, 1987 you requested relief from Section XI of the ASME Boiler and Pressure Vessel Code for the Nine Mile Point Nuclear Station, Unit No.

1 (TAC 67417).

Relief was requested from the requirement to perform the system leakage test of the Reactor Coolant Pressure Boundary at a test pressure not less than the nominal operating pressure associated with 100%

rated reactor power.

Your alternative was to perform the test at 900 psig in lieu of 1035 psig.

Your basis for the requested relief is that performing the test at the required conditions takes additional work which would delay startup.

Radiation considerations were not a basis for this request.

To qualify for relief from the requirements of 10 CFR 50.55a, you must demonstrate to the satisfaction of the Commission that the requirements are impractical.

He conclude that you have not provided a sufficient basis to show impracticality.

Therefore, your request for relief cannot be granted.

Sincerely, cc:

See next page Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects, I/II

  • SEE PREVIOUS CONCURRENCE PDI-1 PDI-1 CVogan*

DNeighbors*:mak 3/04/88 3/04/88 EMTB*

3/04/88 OGC MYoung*

3/08/88 PDI-1 RCapra 3/Ib'/88 880/21 0262 88000~/P0

'DR ADQCK 0500pDR P

h'

s Docket No. 50-220 Mr. Charles V. Mangan Senior Vice President Niagara Mohawk Power Corporation 301 Plainfield Road

Syracuse, New Yor k 13212

Dear Mr. Mangan:

DISTRIBUTION NRCPDR Local PDR PDI-1 Rdg.

TMurley/JSniezek FMiraglia CRossi SVarga BBoger ARM/LFMB HBClayton,EDO CVogan RBenedict DNeighbors OGC EJordan JPartlow TBarnhart(4)

ACRS(10)

GPA/PA JJohnson,RI By letter dated December 7, 1987 you requested relief from Section XI of the ASME Boiler and Pressure Vessel Code for the Nine Mile Point Nuclear Station, Unit No. 1.

Relief was requested from the requirement to perform the system leakage test of the Reactor Coolant Pressure Boundary at a test pressure not less than the nominal operating pressure associated with 100$ rated reactor power.

Your alternative was to perform the test at 900 psig in lieu of 1035 pslg.

Your basis for the requested relief is that performing the test at the required conditions takes additional work which would delay startup.

Radiation considerations were not a basis for this request.

To qualify for relief from the requirements of 10 CFR 50.55a, you must demonstrate to the satisfaction of the Commission that the requirements are impractical.

We conclude that you have not provided a sufficient basis to show impracticality.

Therefore, your request for relief cannot be granted.

Sincerely, Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects, I/II cc:

See next page PDI-1 ~

CVogan 3/6 /88 PD DN hbors:mak 3/

/88 EMTB 3/ /8 OGC 3/

/8

~gC PDI-1 RCapra 3/iq /88

,a n

~ ll 4

ql

Mr. C. V. Mangan Niagara Mohawk Power Corporation Nine h1ile Point Nuclear Station, Unit No. I CC:

Troy R. Conner, Jr.,

Esquire Conner 5 Wetterhahn Suite 1050 1747 Pennsylvania

Avenue, N.

W.

Washington, D.

C.

20006 Frank R. Church, Supervisor Town of Scriba R.

D.

F2

Oswego, New York 13126 Mr. Thomas Perkins General Supt.-Nuclear Generation Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Post Office Box 32
Lycoming, New York 13093 Resident Inspector U. S. Nuclear Regulatory Commission Post Office Box 126
Lycoming, New York 13093 Mr. Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, New York 13202 Regional Administrator, Region I U. S. Nuclear Regulatory Conmission 475 Allendale Road King of Prussia, Pennsylvania 19406 Ms.

Donna Ross New York State Energy Office 2 Empire State Plaza 16th Floor

Albany, New York 12223 Mr. Thomas W.

Roman Unit I Station Superintendent Nine Mile Point Nuclear Station Post Office Box 3P

Lycoming, New York 13093

n