ML17055D346

From kanterella
Jump to navigation Jump to search
Forwards Safety Insp Repts 50-220/87-20 & 50-410/87-36 on 870914-18.No Violations Noted
ML17055D346
Person / Time
Site: Nine Mile Point  
Issue date: 11/05/1987
From: Martin T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mangan C
NIAGARA MOHAWK POWER CORP.
Shared Package
ML17055D347 List:
References
NUDOCS 8711090239
Download: ML17055D346 (6)


See also: IR 05000220/1987020

Text

ACCESSION NBR:

FACIL: 50-220

50-410

AUTH. NAME

MARTINiT. T.

RECIP. NAME

MANQANiC. V.

REGULATORY INFORMATION DISTRIBUTION SYSTEM <BIDS)

871 1090239

DOC. DATE: 87/1 1/05

NOTARIZED:

NO

DOCKET 0

Nine Mile Point Nuclear Stationi Unit ii Niagara

Poee

05000220

Nine Mile Point Nuclear Station>

Unit 2i Niagara

Moha

05000410

AUTHOR AFFILIATION

Region ii Ofc of the Director

RECIPIENT AFFILIATION

Niagara

Mohaek

Power Corp.

SUBJECT:

Foreards

Safety

Insp Repts

50-220/87-20

5 50-410/87-36

on

870914-18.

No violations noted.

DISTRIBUTION CODE:

IE06D

COPIES

RECEIVED: LTR L, ENCL Q

SIZE:

+

TITLE: Environ 5 Radiological

(50 DKT>-Insp Rept/Notice of Violation Respons

NOTES: 21

05000410

RECIPIENT

ID CODE/NAME

PD1-1

LA

BENEDICT> R

BENEDICT'

INTERNAL: ACRS

AEOD/DSP

NMSS/SQOB

NRR/DREP/EPB

NRR/

S/ ILRB

FIL

02

R

EPY GI

RQN2/DRSS/EPRPB

EXTERNAL:

LPDR

NSIC

COPIES

LTTR ENCL

1

0

1

1

1

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

RECIPIENT

ID CODE/NAME

PD1-1

PD

HAUQHEYe M

AEOD/DOA

NMSS/LLOB

NRR/DOEA/EAB

NRR/DREP/RPB

OGC/HDS1

RES

RGNi

FILE

01

RGN4

MURRAY'

NRC

PDR

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

2

2

1

1

1

1

1

1

1

1

1

TOTAL NUMBER OF COPIES

REQUIRED: LTTR, 26

ENCL

25

NOY 05

1987

Docket Nos:

50-220

50-410

Niagara

Mohawk Power

Corporation

ATTN:

Mr. C. V. Mangan

Senior Vice President

301 Plainfield Road

Syracuse,

New York

13212

Gentlemen:

Subject:

Combined Inspection

Report

Nos. 50-220/87-20

and 50-410/87-36

A routine safety inspection

was conducted

by Mr. B. S.

Davidson of this office

on September

14-18,

1987 of the solid radwaste

and transportation activities.

at the Nine Mile Point Nuclear Station, Scriba,

New York.

Our findings were

discussed

with Messrs.

T.

Roman

and T. Perkins

and others of your staff at the

conclusion of the inspection

on September

18,

1987.

The areas

examined during this inspection

are described

in the

NRC Region I

Combined Inspection

Report which is enclosed with this letter.

Within these

areas,

the inspection consisted of selective

examination of procedures

and

representative

records,

interviews with personnel

and observations

by the

inspector..

Within the scope of this inspection,

no violations were observed.

No reply to this letter is required.

Your cooperation with us in this matter

is appreciated.

Sincerely,

Original Signed By::

Ronald R. Bellatnyg

Thomas

T. Martin, Director

Division of Radiation Safety

and Safeguards

Enclosure:

NRC Combined Inspection

Report

Nos. 50-220/87-20

and 50-410/87-36

ii090239 87ii05

PDR

  • DOCK 05000220

8

PDR

t'E-UR> ORlGlNAL

TO

PEG(ON

l

OFFICIAL RECORD

COPY

Niagara

Mohawk Power Corporation

VOV CS

1997

cc w/encl:

T.

E.

Lempges,

Vice President,

Nuclear Generation

T. Perkins,

General

Superintendent,

Nuclear Generation

W. Hansen,

Manager of Quality Assurance

J.

A. Perry, Vice President,

Quality Assurance

T.

Roman, Station Superintendent

J. Aldrich, Supervisor,

Operations

W. Drews, Technical

Superintendent

Troy B. Conner, Jr., Esquire

Director,

Power Division

Connor

5 Wetterhahn

John

W. Keib, Esquire

D.

Quamme,

NMP-2 Project Director

C.

Beckham,

NMPC QA Manager

R.

B. Abbott, Station Superintendent

Department of Public Service,

State of New York

Public Document

Room

(PDR)

Local Public Document

Room

(LPDR)

Nuclear Safety Information Center

(NSIC)

NRC Resident

Inspector

State of New York

bcc w/encl:

Region I Docket

Room (with concurrences)

Management Assistant,

DRMA (w/o encl)

DRP Section Chief

Region I, SLO

Robert J. Bores,

DRSS

RI:DRSS~

DavidsoA~'"

10/27/87

scfg /87

RI:DRSS

Bellamy

1 /3/87

RI DSS

Mar i

10/

87

OFFICI

L RECORD

COPY

cir nm 87-20/36

10/13/87