Forwards Revised Page 6-1 to Final Draft Tech Specs, Inadvertently Omitted from Package Transmitted on 860910. Revised Page Should Be Included in Certification Process
ML17055C392
Person / Time
Site: Nine Mile Point 
Issue date: 09/11/1986
From: Adensam E
Office of Nuclear Reactor Regulation
To: Mangan C
NIAGARA MOHAWK POWER CORP.
References
NUDOCS 8609180142
Download: ML17055C392 (6)


Text

September ll, 1986 Docket No. 50-410 Mr. C.

V. Mangan, Senior Vice President Niagara Mohawk Power Corporation 300 Erie Boulevard West

Syracuse, New York 13202

Dear Mr. Mangan:

ACRS (10)

D IS IBUTION:

c et o.

0-410 NRC PDR Local PDR BWD-3 r/f EAdensam MHaughey EHylton CSchulten DVassallo

Attorney, OGC BGrimes EJordan JPartlow

Subject:

Changes to the Final Draft Technical Specifications for Nine Mile Point, Unit 2 On September 10,

1986, we sent you the revised pages to the Final Draft Technical Specifications which were the result of our review of your requested changes to the Technical Specifications through August 22, 1986.

Page 6-1 of the Technical Specifications contained some approved changes but was inadvert-ently left out of the package transmitted to you on September 10, 1986.

The revised page 6-1 is enclosed and should be included in your certification process.

Sincerely,

Enclosure:

As stated cc:

See next page

/S/

Elinor G. Adensam, Director BWR Project Directorate No.

3 Division of BWR Licensing Lg

-:DBL EjlIJJ ton 9/I /86 MHaughey/hmc 9///'/86 8609180142 860911 PDR

'ADOCK 05000410 PDR gg(( /86 D.

D 3:DBL EA sam

, ~

F F,f

'I CI

a ~ <<<<<<'<< ~ <<<<<<

. ~ ~ <<<<w

=-

~ l I<<

Mr. C. V. Mangan Niagara Mohawk Power Corporation I

CC:

Mr. Troy B. Conner, Jr.,

Esq.

Conner 5 Wetterhahn Suite 1050 1747 Pennsylvania

Avenue, N.W.

Washington, D.C.

20006 Richard Goldsmith Syracuse University College of Law E. I. White Hall Campus

Syracuse, New York 12223 Ezra I. Bialik Assistant Attorney General Environmental Protection Bureau New York State Department of Law 2 World Trade Center New York, New York 10047 Resident Inspector Nine Mile Point Nuclear Power Station P. 0.

Box 99

Lycoming, New York 13093 Mr. John W. Keib, Esq.

Niagara Mohawk Power Corporation 300 Erie Boulevard West

Syracuse, New York 13202 Mr. James Linville U. S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 Norman Rademacher, Licensing Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, New York 13202 Don Hill Niagara Mohawk Power Corporation Suite 550 4520 East West Highway
Bethesda, Maryland 20814 Nine Mile Point Nuclear Station Unit 2 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Mr. Paul D. Eddy New York State Public Serice Commission Nine Mile Point Nuclear Station Unit II P.O.

Box 63 Lycoming,'ew York 13093

~,

t'

>>s

~

~

i

~

W )lwv>>'ai ~>>,"k a sLi'> ll EL'li'>>IV44%r /+jul'e'r4jq>>t(>>i;9 wg'lg4.,'NAl >>,

1>> ~ A, a'w 'jl>>+>>

  • p L
6. 0 ADMINISTRATIVE CONTROLS
6. 1 RESPONSIBILITY 6.1.1 The General Superintendent - Nuclear Generation shall be responsible for overall unit operation and shall delegate in writing the succession to this responsibility during the Superintendent's absence.-

6.1.2 The Station Shift Supervisor - Nuclear (or during the Supervisor's absence from the control room, a designated individual) shall-be responsible for the control room command function.

A management directive to this effect, signed by the Vice President - Nuclear Generation shall be reissued to all station personnel annually.

6. 2 ORGANIZATION OFFSITE 6.2.1'he offsite organization for unit management and technical support shall be as shown on Figure 6.2. 1-1.

UNIT STAFF 6.2.'.

b.

C.

d.

e.

2 The unit organization shall be as shown on Figure 6.2.2-1 and:

\\

Each on-duty shift shall be composed of at least the minimum shift crew shown in Table 6.2.2-1; At least one Licensed Operator shall be in the control room when fuel is in the reactor.

In OPERATIONAL CONDITIONS 1, 2, or 3, at least one Licensed Senior Operator or Licensed Operator shall be at the controls of the unit.

A Radiation Protection Technician" shall be on site when fuel is in the reactor; I

At least'wo Licensed Operators shall be present in the:control room during reactor startup, scheduled reactor shutdown, and during recovery from reactor trips.

A Licensed Senior Operator shall be required 9n the control room during OPERATIONAL CONDITIONS 1, 2, and 3 and when the emergency plan is activated.

Th'is may be the Station Shift Supervisor - Nuclear, the Assistant Station Shift Supervisor - Nuclear or other individuals with a valid senior opera-tor license.

When the emergency plan is activated in OPERATIONAL CONDITIONS 1, 2, or 3 the Assistant Station Shift Supervisor - Nuclear becomes the Shift Technical Advisor and the Station Shift Supervisor-Nuclear becomes the Shift Technical Advisor and the Station Shift

" The Radiation Protection Technician and Fire Brigade composition may be less than the minimum requirements for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, in order'o accommodate unexpected

absence, provided immediate action is taken to fillthe required positions.

This provision does not permit any shift crew position to be unmanned upon shift change due to an oncoming crewman being late or absent.

. NINE MILE POINT - UNIT 2 6-1 SEP 0 88

L'