Docket No. 50-220 JAN 06 1g86 Niagara Mohawk Power Corporation Attn:

Mr. C. V. Mangan Senior Vice President c/o Miss Catherine R. Seibert 300 Erie Boulevard West

Syracuse, New York 13202

Dear Mr. Mangan:

SUBJECT:

REVISION TO INSERVICE INSPECTION PROGRAM Re:

Nine Mile Point Nuclear Station, Unit No.

1 We have completed our review of your submittals dated March 7, 1984 and November 25, 1985 regarding your proposed revisions to the facility Inservice Inspection Program.

Based on our review, we find the proposed changes acceptable since they are consistent with 10 CFR 50.55a(g)(4)(iv).

The Safety Evaluation supporting our findings is enclosed.

Sincerely, John A. Zwolinski, Director BWR Project Directorate ¹1 Division of BWR Licensing

Enclosure:

As stated cc w/enclosures:

See next page DISTRIBUTION

~ oc et s

e NRC PDR Local PDR BWD¹1 Rdg RBernero OELD EJordan BGrimes JPartlow RHermann CJamerson ACRS (10)

DBLX

CJamers, n

i4'g9'/85 Q4 -P~

DBL: PD¹1 RHerngnn:tm

]8 /+$85 DBL:PD¹1 JZwolinski

>z, / pf/85 860i090457 860i06 PDR ADOCK 05000220 I

6

'DR

~p,ll AEONS

~ +

0 Cy

~

0 C

O I

o~

Cy

+p*~4 Docket No. 50-220 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 January 6, l986 Niagara Mohawk Power Corporation Attn:

Mr. C.

V. Mangan Senior Vice President c/o Miss Catherine R. Seibert 300 Erie Boulevard West

Syracuse, New York 13202

Dear Mr. Mangan:

SUBJECT:

REVISION TO INSERVICE INSPECTION PROGRAM Re:

Nine Mile Point Nuclear Station, Unit No.

1 We have completed our review of your submittals dated March 7, 1984 and November 25, 1985 regarding your proposed revisions to the facility Inservice Inspection Program.

Based on our review, we find the proposed changes acceptable since they are consistent with 10 CFR 50.55a(g)(4)(iv).

The Safety Evaluation supporting our findings is enclosed.

Sincerely,

Enclosure:

As stated John A

Zwolinski, Director BWR Project Directorate ¹1 Division of BWR Licensing cc w/enclosures:

See next page

Mr. C. V. Mangan Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station, Unit No.

1 CC:

Troy B. Conner, Jr., Esquire Conner 5 Wetterhahn Suite 1050 1747 Pennsylvania

Avenue, N.

W.

Washington, D.

C.

20006 Frank R. Church, Supervisor Town of Scriba R.

D. 82

Oswego, New York 13126 Niagara Mohawk Power Corporation ATTN:

Mr. Thomas Perkins Plant Superintendent Nine Mile Point Nuclear Station Post Office Box 32

Lycoming, New York 13093 Resident Inspector U. S. Nuclear Regulatory Commission Post Office Box 126
Lycoming, New York 13093 John W. Keib, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, New York 13202 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Mr. Jay Dunkleberger Division of Policy Analysis and Planning New York State Energy Office Agency Building 2 Empire State Plaza
Albany, New York 12223

0