I
REGULATORY INFORNATION DISTRIBUTION BYSTEN (R IDS)
ACCESSION
NaR: 870a080054
DOC. DAT~: 87/05/2V
NOTARIZED:
NO
DOCXET e
AC IL 50410 Nine Nile Point Nuclear Station>
Unit 2.
Ni agar a
Noh".
05000410
TH. NAriE
AUTHOR AFFILIATION
NSTON, lJ. V.
Reg i on
1 i Office
o f Direc tor
RECIP. NAI'1E
RECIPIENT AFFILIATION
NANQAN> C. V.
Niagara
Nohawk Power
Corp.
BUBJECT:
Forwards
Insp Rept 50-410/87-14
on 870413-17
up
on activities re installation of Rockwell
type
I'1BIVs. No violations noted.
DISTR
INPUT
ION CODE:
IE01D
COPIES
RFCEIVED: LTR
i
ENCL
TITLE: Qeneral
(50 Dkt)-Insp Rept/Notice of Violation
NOTES:
Insp folio:<cd
Y patern
globe
sz zz:
cL~W
Response
REC IPIENT
ID CODE/NANE
PD1-1
LA
NEIQHDORS> D
INTERNAL:
ACRB
DEDRO
NRR ROE,N. L
NRR/DREP /EPB
NRR/DRIS DIR
OQC/HDBi
DEPY Ql
RNAL:
LPDR
NBIC
COPIES
LTTR ENCL
1
0
RECIPIENT
I D CODE /MANE
PD1-1
I'iINER~ S
ENF LIEBERMAN
MRR/DOEA DIR
NRR/DREP/RPB
'RR/PNAB/ILRD
RCN1
FILE
01
NRC
COP IES
LTTR EN"L
1
1
1
1
1
2
2
1
1
1
1
1
1
1
TOTAL NUBBER OF COPIES
REQUIRED:
LTTR
25
ENCL
24
5)AY
2 9 1987
Docket No.
50-410
Niagara
Mohawk Power Corporation
ATTN:
Mr. C. V. Mangan
Senior Vice President
301 Plainfield Road
Syracuse,
13212
Gentlemen:
Subject:
Inspection
No. 50-410/87-14
This letter refers
to the routine safety
inspection
conducted
by Mr. H. Gregg
of this office
on April 13-17,
1987,
at the
Nine Mile Point Nuclear Station,
Unit 2, Scriba,
Mr. Gregg
discussed
the findings of the
inspection
with Mr.
M.
Ray and other members of your staff at the conclusion of the onsite
inspection,
The objective
of this inspection
was to follow-up on your activities related
to installation of the
new Rockwell "Y" pattern
globe type Main Steam Isolation
Valves
(MISVs).
These
new valves
have
replaced
the
Crosby ball
type
Areas
examined
during
this
inspection
are
described
in
the
NRC
Region I
Inspection
Report which is enclosed with this letter.
Within these
areas,
the
inspection
consisted
of selective
examinations
of records,
interviews
with
personnel,
and observations
by the inspector.
Within the
scope of this inspection,
no violations were observed.
No reply to this letter is required.
Your cooperation
with us in this matter
is appreciated.
Sincerely,
pg,ca~<~'"
William V. Johnston,
Acti g Director
Division of Reactor Safety
Enclosure:
NRC Region I Inspection
Report
No. 50-410/87-14
Wag 8 '7
p
SVQO>~
70bQgQQ5
Q5QQQgfQ
R
AgQG
ping
9
OFFICIAL RECORD
COPY
IR NMP2 87-14
0001.0
~ 0
05/22/87
11
Niagara
Mohawk Power Corporation
cc w/encl:
Connor
8 Wetterhahn
John
W. Keib, Esquire
J.
A. Perry,
Vice President,
Quality Assurance
W. Hansen,
Manager of Quality Assurance
D.
Quamme,
NMP-2 Project Director
C.
Beckham,
T. J. Perkins,
General
Superintendent'.
B. Abbott, Station Superintendent
Department of Public Service,
State of New York
Public Document
Room (PDR)
Local Public Document
Room (LPDR)
Nuclear Safety Information Center
(NSIC)
NRC Resident
Inspector
State of New York
bcc w/encl:
Region I Docket
Room (with concurrences)
Management Assistant,
DRMA (w/o encl)
Region. I SLO
Robert J.
DRSS
J. Linville, DRP Section Chief ¹2C
J. Beall
L. Tripp
RI: DRS
STA5
5/~/87
RI:DRS
Strosnider
5/z4/87
RI: DRS
Durr
5/~'7/87
OFFICIAL RECORD
COPY
IR NMP2 87-14 " 0001.0.1
05/22/87