APPENDIX A NOTICE OF VIOLATION Niagara Mohawk Power Corporation Nine Mile Point Unit 2 Docket No. 50-410 License No.

CPPR-112 As a result of the inspection conducted on July 27-31,

1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980),

the following violation was identified:

10 CFR 50, Appendix B, Criterion V, states, in part, that:

"Activities affecting quality shall be prescribed by documented instructions.

and shall be accomplished in accordance with these instructions.

Section D.3.6 of PSAR, Appendix D, states, in part, that:

"Written procedures are promulgated by gA.

Department.

..for assuring that the quality of material and equipment is maintained from receipt, through installation.

.so that there will be no degradation or deterioration of material or equipment."

Section 5.1.4 of Specification E-061A states, in part,, that:

"All motors shall have motor winding'

.resistance megger tested as specified in section 2.6.3.

All test reports shall be submitted to the engineers for evaluation."

Contrary to the above, On July 30,

1981, Pump Motor electrical test data obtained by one contractor and stored by another had not been submitted to the Engineer s for evaluation.

This is a Severity Level V Violation.

(Supplement II)

Pursuant to the provisions of 10 CFR 2.201, Niagara Mohawk Power Corporation is hereby required to submit to this office within twenty-five days of the date of this Notice, a written statement or explanation in reply, including:

(1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further violations; and (3) the date when full compliance will be achieved.

Under the authority of Section 182 of the Atomic Energy Act of 1954, as

amended, this response shall be submitted under oath or affirmation.

Where good cause is shown, consideration will be given to extending your response time.

OFFICIAL RECORD COPY t 8i09240543 8i090i i PDR ADOCK 050004i0,'G PDRi,'

~

~

0

~

~

Appendix A The responses directed by this Notice are not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

Dated SEP 01 lggl E.J.

Brunner, Chief, Projects Branch ¹I, Division o' Resident and Project Inspection OFFICIAL RECORD COPY