ML17053C579

From kanterella
Jump to navigation Jump to search
Safety Evaluation Rept Re Primary Coolant Sys Pressure Isolation Valves (WASH-1400,Event V)
ML17053C579
Person / Time
Site: Nine Mile Point 
Issue date: 04/20/1981
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML17053C578 List:
References
NUDOCS 8105010577
Download: ML17053C579 (2)


Text

ghee REGIj, Cr+

4tpo Cy O

<c <

'y

~O

+a**~

UNITEDSTATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 Attachment 1

SAFETY EVALUATION REPORT NINE MILE POINT NUCLEAR STATION, UNIT 1

PRIMARY COOLANT SYSTEM PRESSURE ISOLATION VALVES (WASH-1400, EVENT V)

1. 0 Introducti on The Reactor Safety Study (RSS),

MASH-1400, identified in a PWR an intersystem loss of coolant accident I.OCA) which is a significant contributor to risk of core melt accidents (Event V).

The design examined in the RSS contained in-series check valves isolating the high pressure Primary Coolant System (PCS) from the Low Pressure Injection System (LPIS) piping.

The scenario which leads to the Event V accident is initiated by the failure of these check valves to function as a pressure isolation barrier.

This causes an overpressurization and rupture of the LPIS low pressure piping which results in a LOCA that bypasses containment.

In order to better define the Event V concern, all light water reactor licensees were requested by,. 10 CFR 50.54(f) letter, dated February 23, 1980, to identify valve configurations of concern and prior valve test results, if any.

By letter dated March 19, 1980, the licensee responded to our request and this information was subsequently transmitted to our contractor, the Franklin Research Center, for verification that the licensee had correctly identified the subject val ve configurati ons.

2.0 Evaluation In order to prepare the Technical Evaluation Report (TER) it was necessary that the contractor verify and evaluate the licensee's response to our February 1980 letter..

The NRC acceptance criteria used by Franklin were based on WASH-1400 findings, probabi listic analyses and appropriate Standard Review Plan requirements.

With respect to the verification of the licensee's response to our information request, the Franklin evaluation was based on FSAR information, ISI/IST site visit data, and other previously docketed information.

The attached Franklin TER correctly identifies the subject valve configurations.

3.0 Conclusion Based on our review of the Franklin TER, we find that the valve configurations of concern have been correctly identified.

Since periodic testing of these PCS pressure isolation valves will reduce the probability of an intersystem LOCA we, therefore,.conclude that the requirement to test these valves should be incor-porated into the plant's Technical Specifications.

Dated: April 20.,

1981