gp,fl REoy, fp0 fl

++*++

Docket No. 50-220 0

~

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA19406 DEC 18 1980

~ ~

~c, L

p ~ (Q~

gcno 8

C9 fCl C/)

H~

flip CO@

Niagara mohawk Power Corporation ATTN:

ter. T.

E.

Lempges Vice President Nuclear Generation 300 Erie Boulevard West

Syracuse, New York 13202 Gentlemen:

The enclosed Supplement No.

4 to IE Bulletin No. 80-17, "Failure of Control Rods to Insert During a Scram at a BWR" is forwarded to you for action.

A written response is required.

In order to assist the NRC in evaluating the value/impact of each Bulletin on licensees, it would be helpful if you would provide an estimate of the manpower expended in conduct of the review and preparation of the report(s) required by the Bulletin.

Please estimate separately the manpower associated with corrective actions following identification of problems through the Bulletin.

If you desire additional information regarding this matter, please contact this office.

Sincerely,

~ZW>7,

/ZPZe~z~~

B ce H. Grier irector

Enclosures:

1.

Supplement No.

4 to IE Bulletin No. 80-17 2.

List.of Recently Issued IE Bulletins CONTACT:

D.

L. Caphton (215-337"5266) cc w/encls:

T.

Roman, Station Superintendent R. Abbott, Operations Supervisor E.

B. Thomas, Jr.,

Esquire 8101 0'to'