Forwards IE Info Notice 80-40, Excessive Nitrogen Supply Pressure Actuates Safety Relief Valve Operation to Cause Reactor Depressurization. No Written Response Required
ML17053C102
Person / Time
Site: Nine Mile Point 
Issue date: 11/07/1980
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Rhode G
NIAGARA MOHAWK POWER CORP.
References
NUDOCS 8012030780
Download: ML17053C102 (2)


Text

~S REQy~

P

~4 0

0 C

Og Gp o~

n +~*y4

. ~

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIAIS408 November 7, 1980

~~'+i~ r&r Docket No. 50-410 Niagara Mohawk Power Corporation ATTN:

MI'. Gerald K.

Rhode Vice President System Project Management c/o Miss Catherine R. Seibert 300 Erie Boulevard, West

Syracuse, New York 13202 Gentlemen:

The enclosed IE Information Notice No. 80'-40, "Excessive Nitrogen Supply Pressure Actuates Safety-Relief Valve Operation to Cause Reactor Depressurization,"

is forwarded to you for information.

No written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, Boyce H.

Gr ier Director Encl osur es:

1.

IE Information Notice No. 80-40 2.

List of Recently Issued IE Information Notices CONTACT:

D.

L. Caphton t,'215-337-5266) cc w/encls: