~yll AEC(
0 ty nO I
I4
,c g 0Y~
+~
~O
+>>*+~
t UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA19406 July 22, 1980 Oocket No. 50-220 Niagara Mohawk Power Corporation ATTN:
Mr. T.
E.
Lempges Vice President Nuclear Generation 300 Erie Boulevard West
- Syracuse, New York 13202 Gentlemen:
The enclosed Supplement No.
2 to IE Bull'etin No. 80-17, "Failure of 76 of 185 Control Rods to Fully Insert Ouring a Scram at a BWR," is forwarded to you for action.
A written response is required.
This transmittal confirms the information and action required that was conveyed by telephone to you on July 19, 1980.
In order to assist the NRC in evaluating the value/impact of each Bulletin on licensees, it would be helpful if you would provide an estimate of the manpower expended in conduct of the review and preparation of the report(s) required by the Bulletin. Please estimate separately the manpower associated with corrective actions necessary following identification of problems through the Bulletin.
If you desire additional information regarding this matter, please contact this office.
Sincerely, Bo ce H. Grier
't
Enclosures:
1.
Supplement No.
2 to IE Bulletin No. 80-17 2.
List of Recently Issued IE Bulletins CONTACT:
D.
L. Caphton (215-337-5266) cc w/encls:
T. J.
- Perkins, General Superintendent, Nuclear Generation T.
Roman, Station Superintendent R. Abbott, Operations Supervisor E.
B. Thomas, Jr.,
Esquire
,80080VOlgP