ML17048A176
| ML17048A176 | |
| Person / Time | |
|---|---|
| Site: | Callaway (NPF-030) |
| Issue date: | 03/03/2017 |
| From: | Klos L Plant Licensing Branch IV |
| To: | Diya F Union Electric Co |
| Klos L | |
| Shared Package | |
| ML17048A160 | List: |
| References | |
| CAC MF8878 | |
| Download: ML17048A176 (4) | |
Text
~o~ozz ~
REV.
DATE DRAWN 4
052490 SBR CHKD. SUPV.
APPD.
RBF HLP N/A REDRAWN FOR CLARITY &
IN CORP.
DEC-421 &
DEC-441 REV.
DATE DRAWN 5
050393 RBF H CHKD. SUPV.
APPD.
DJB T JM N/A IN CORP.
RFR-133628 REV.
DATE DRAWN 6
021194 GDC CHKD. SUPV.
APPD.
SYSTEM DESIGNATOR RAM T JM N/A IN CORP.
RFR-14573 A.
REV.
DATE 7
041905 NO. OF SHEETS NO. OF SHEETS DRAWN CHKD. SUPV.
MAL RLW TWS MAIN POWER CYCLE AND AUXILIARIES P & ID HVAC P & ID INCDRP.
AB MAIN STEAM 7
GA PLANT HEATING 2
RFR 22941A AC MAIN TURBINE 4
GB CENTRAL CHILLED WATER 1
AD CONDENSATE 8
GD ESSENTIAL SERVICE WATER PUMP HOUSE BUILDING HVAC
( P & I D-1 M-U2 DWG. l 1
AE FEED WATER 2
AF FEEDWATER HEATER EXTRACTION. DRAINS & VENTS 4
G AK CONDENSATE DEMINERALIZER 4
GH RADWASTE BUILDING HVAC 2
GK CONTROL BUILDING HVAC 4
AN DEMINERALIZED WATER STORAGE & TRANSFER 1
GL AUXILIARY BUILDING HVAC 3
AP CONDENSATE STORAGE AND TRANSFER 1
GM DIESEL GENERATORS BUILDING HVAC 1
AO CONDENSATE AND FEEDWATER CHEMICAL ADDITION 2
GN CONTAINMENT COOLING 2
NOTES:
GS CONTAINMENT HYDROGEN CONTROL 1
GR CONTAINMENT ATMOSPHERIC CONTROL 1
1.
THIS DRAWING PROVIDES THE SYSTEM GT CONTAINMENT PURGE HVAC 1
DESIGNATORS USED IN THE P & I D GF MISCELLANEOUS BUILDING HVAC 2
AND FLOW DIAGRAM DRAWING NUMBERS.
GP CONTAINMENT INTEGRATED LEAK RATE TEST 1
DRAWINGS M-220102, M-220103, AND M-220104 PROVIDE THE APPLICABLE SYMBOLS AND LEGEND.
NO. OF SHEETS
- 2.
DRAWING NUMBERING SYSTEM IS AS REACTOR AND STEAM GENERATOR CONTROLS AND AUXILIARIES P & ID FOLLOWS:
BB REACTOR COOLANT 4
BG CHEMICAL AND VOLUME CONTROL 5
BL REACTOR MAKEUP WATER 1
DESIGNATOR CODE F
BM STEAM GENERATOR SLOWDOWN 5
NO. OF SHEETS (FLOW DIAGRAMS ARE BN BORATED REFUELING WATER STORAGE 1
RADWASTE P & ID IDENTIFIED BY 11111 AND HA GASEOUS RADWASTE 3
p & I D I s By II 2 II )
HB LIQUID RADWASTE 5
MECH.
_[SHEET NO.
HC SOLID RADWASTE 4
DISCIPLINEl HD DECONTAMINATION 1
HE BORON RECYCLE 3
EXAMPLE:
M-22AB01 HF SECONDARY LIQUID WASTE SYSTEM 5
APPLICABLE UNITS J NO. OF SHEETS TURBINE GENERATOR CONTROLS AND AUXILIARIES p & ID SYSTEM CA STEAM SEAL 1
(CALLAWAY UNIT 1 CB MAIN TURBINE LUBE OIL 1
= 2 cc GENERATOR HYDROGEN AND C02 1
CALLAWAY ONLY CD GENERATOR SEAL OIL 1
= Ul CE STATOR COOLING WATER 1
CF LUBE OIL STORAGE, TRANSFER & PURIFICATION 2
NO. OF SHEETS
- 3.
SEE DRAWING 8600-X-89846 FOR S & P E CG CONDENSER AIR REMOVAL 1
FUEL p & ID p & I D INDEX.
CH MAIN TURBINE CONTROL OIL 1
JE EMERGENCY FUEL OIL 1
NO. OF SHEETS CIRCULATING WATER P & ID DA CIRCULATING WATER 2
NO. OF SHEETS SERVICES P & ID KA COMPRESSED AIR 7
KB BREATHING AIR SYSTEM 3
KC FIRE PROTECTION 7
D KD DOMESTIC WATER 2
KE FUEL HANDLING, FUEL STORAGE & REACTOR VESSEL SERVICE NONE NO. OF SHEETS KH SERVICE GAS ( co 2. N 2, H 2,
& 0 2 )
2 EQUIPMENT & EMERGENCY CORE COOLING WATER P & I D KJ STANDBY DIESEL ENGINE 6
KS BULK CHEMICAL STORAGE (p & I D-1 M-U2 DWG. l 1
EB CLOSED COOLING WATER 1
EC FUEL POOL COOLING & CLEANUP 2
EF ESSENTIAL SERVICE WATER
( p & I D S-2 M-22 DWGS., 1 M-U2 DWG. l 3
EG COMPONENT COOLING WATER 3
EM HIGH PRESSURE COOLANT INJECTION 2
EN CONTAINMENT SPRAY 1
NO. OF SHEETS EP ACCUMULATOR SAFETY INJECTION 1
DRAINS P & ID LA SANITARY DRAINS 2
c LD CHEMICAL AND DETERGENT WASTE 1
LE OILY WASTE 4
LF FLOOR & EQUIPMENT DRAINS 1 0 NO. OF SHEETS AUXILIARY STEAM P & ID FA AUXILIARY STEAM GENERATOR 1
FB AUXILIARY STEAM 2
FC AUXILIARY TURBINES 3
FE AUXILIARY STEAM CHEMICAL ADDITION SYSTEM 1
NO. OF SHEETS SAMPLING SYSTEMS P & ID RM PROCESS SAMPLING AND ANALYSIS 3
SJ NUCLEAR SAMPLING 4
B AS-BUILT DRAWN WATE I DRAWING INDEX A
N/A CHKD.
WATE J FOR SYSTEM FLOW AND A
N/A PIPING AND SUPV.
WATE J INSTRUMENT DIAGRAMS N/A
~n~AR FIGURE 1. 1-1 SHEET 1 l" APPO.
(0/I.T[ J LOCATION CLASS N/A CALLAWAY PLANT UNION ELECTRIC COMPANY M-220101 REV.
8 7
6 5
4 3
2 1
HVAC LINES
---~----
I I
-E--E-*
__ _,Il----
l DUCTED AIR FLOW AIR MOVEMENT
<NDN-DUCTEDl DUCTED AIR FLOW TO SPACE DUCTED AIR FLOW FROM SPACE EXHAUST HOOD ESSENTIAL AIR MOVEMENT
<NDN-DUCTEDl FOR NUCLEAR PLANTS ORIFICE PLATE COILS
<Hl HEATING COIL
<HWl HOT WATER (SHOWNl
<Sl STEAM
<El ELECTRIC
<Gl GAS
<Cl COOLING COIL
( CH l REFRIG. CHILLED WATER <SHOWNl
<CWl COOLING WATER
<DXl REFRIGERANT DIRECT EXPANSION HUMIDIFIERS
-- ~sl-*
G
<SGl LOW PRESSURE STEAM GRID
<SHOWNl
<Sl STEAM PAN
<Hl HOT WATER PAN
<El ELECTRIC PAN DUST COLLECTORS CDC 1---*
01-----
8 (CDClCYCLONE DUST COLLECTOR
<SHOWNl
<BDClBAG TYPE DUST COLLECTOR DYNAMIC TYPE DUST COLLECTOR 7
I FANS
-EJ CENTRIFUGAL BLOWER DR COMPRESSOR CENTRIFUGAL FAN CENTRIFUGAL FAN WITH INLET VANES r-..
§ VANE AXIAL FAN
-[li]t---
PROPELLER FAN
'IH /1-----
.... 1/ E UNIT HEATER ELECTRIC COIL SHOWN;
<SEE UNDER COILS FOR DEFINITIONS OF OTHER LETTER SYMBOLS)
AIR CLEANING DEVICES LOW EFFICIENCY ROLL TYPE FILTER LOW
-LOW EFFICIENCY ROUGHING FILTER.
10% TO 85% EFFIC-IENCY BY ASHRAE WEIGHT TEST MOD MODERATE EFFICIENCY FILTER. 20% TO 60%
EFFICIENCY BY ASHRAE STAIN TEST HIGH - HIGH EFFICIENCY FILTER 85% EFFIC-IENCY BY ASHRAE STAIN TEST TO 95%
EFFICIENCY FOR 0.03 MICROMETER DDP HEPA - HIGH EFFICIENCY PARTICULATE AIR FILTER. 99.97% EF-FICIENCY FOR 0.30 MICROMETER DOP CHAR - ACTIVATED CHARCOAL ADSORBER TRAY DR DEEP BED TYPE ELEC - ELECTROSTATIC PRECIPITATOR SU
- LOW-EFFICIENCY FILTER TO BE REMOVED AFTER START UP MS
- MOISTURE SEPARATOR LOUVERS FIXED ADJUSTABLE 6
¢
rr-r- ' -
OPPOSED BLADE
-rtf-- PARALLEL BLADE
1t f-- BACKDRAFT OR GRAVITY RELIEF
1"-.t--l -
SINGLE BLADE OR BUTTERFLY
---I[SJt---
1"'
4 +...r---1----
MANUAL BALANCE FUSIBLE LINK FIRE DAMPER OR FIRE DOOR BUBBLE TIGHT SPRING ACTUATED BACKDRAFT DAMPER NOTE:
REFER TO SHEET M-220104 FOR ACTUATOR SYMBOLS FIRE PROTECTION EQUIPMENT
- 0)
---1<1~*"--
--HI[) I *
--tii!Z]f+ -J2JI--
--+10H-I-
--II WMA t-1 ---
FIRE HYDRANT FIRE HYDRANT WITH HOSE HOUSE HOSE REEL STATION HOSE RACK STATION DELUGE VALVE ALARM CHECK VALVE DRY PIPE VALVE POST INDICATOR VALVE BALL DRIP VALVE FIRE SYSTEM WATER MOTOR ALARM HALON SYSTEM SELECTOR VALVE
- 0) HALON SYSTEM tt
--~1--
1\\
---lA t
~I II\\
CYLINDER CONTROL VALVE HALON SYSTEM MANUAL PNEUMATIC ACTUATOR VALVE HALON SYSTEM MANUAL MAIN/RESERVE SWITCHING VALVE HALON SYSTEM BLEEDER VALVE STAND PIPE FIRE BRIGADE CONNECTION SPRINKLER HEAD SPRAY NOZZLE INSPECTOR TEST CONNECTION 5
SUPPLEMENTARY INSTRUMENT DESIGNATIONS ID u
(XAH\\DISCH VHORN (XAH\\DISCH VLIGHT FIRE DETECTOR ID=IDNIZATIDN DETECTOR PD=PHOTOELECTRIC DETECTOR XD=FLAME DETECTOR ND=FIXED TEMPERATURE THERMAL DETECTOR RD=RATE OF RISE THERMAL DETECTOR CD=RATE COMPENSATED THERMAL DETECTOR LD=CONTINUOUS LINE TYPE DETECTOR FIRE ALARM BELL PANEL MOUNTED ALARM ANNUNCIATOR FIRE DETECTION SYSTEM ACTUATION VALVE SUPERVISION DISCHARGE ALARM HORN DISCHARGE ALARM LIGHT PLUMBING LINES CW DOMESTIC COLD WATER HW --
--HWR--
--THW--
--THWR--
--VAC--
--SAN--
--V AW
-- AV ow--
-- ov TP --
--GCS--
--LRW--
-LRV--
--ARW--
-ARV--
--SRW--
- -SRV--
G
--DRW--
--CRW--
--DRY--
--CRY--
DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER RETURN DOMESTIC TEMPERED HOT WATER SUPPLY DOMESTIC TEMPERED HOT WATER RETURN VACUUM STORM DRAINAGE SANITARY DRAINAGE SANITARY VENT ACID WASTE ACID VENT OILY WASTE OILY VENT TRAP PRIMER GRAVITY COLLECTION SYSTEM POTENTIALLY RADIOACTIVE LIQUID WASTE POTENTIALLY RADIOACTIVE LIQUID WASTE VENT POTENTIALLY RADIOACTIVE CHEMICAL WASTE POTENTIALLY RADIOACTIVE CHEMICAL WASTE VENT POTENTIALLY RADIOACTIVE DETERGENT WASTE POTENTIALLY RADIOACTIVE DETERGENT WASTE VENT NATURAL, MIXED OR MANUFACTURED GAS DIRTY RADWASTE FLOOR AND EQUIPMENT DRAINS
<NORMALLY NON-TRITIATED)
CLEAN RADWASTE FLOOR AND EQUIPMENT DRAINS
<NORMALLY TRITIATED)
DIRTY RADWASTE FLOOR AND EQUIPMENT DRAINS
<NORMALLY NON-TRITIATED)
SYSTEM VENT CLEAN RADWASTE FLOOR AND EQUIPMENT DRAINS
<NORMALLY TRITIATED)
SYSTEM VENT 4
I EQUIPMENT &
FIXTURES CSK CUP SINK <SHOWNl DF DRINKING FOUNTAIN ESEW EMERGENCY SHOWER & EYE EW EYE WASH EWC ELECTRIC WATER COOLER HB HOSE BIB KSK KITCHEN SINK L
LAVATORY LSK LABRATDRY SINK MSK MOP SINK HMSK HOT MOP SINK SH SHOWER SK SINK SSK SERVICE SINK UR URINAL US UTILITY STATION WC WATER CLOSET WF WASH FOUNTAIN WH WALL HYDRANT YH YARD HYDRANT w
HSH DW SGK WASHER HOT SHOWER DISHWASHER FIRST AID SINK DRAINS DIRECT DRAIN
~
INDIRECT DRAIN
(\\ v ROOF DRAIN WASH FLOOR DRAIN OR SURFACE COLLECTION UNIT L,J 3
EQUIPMENT DRAIN COLLECTION UNIT PLUGGED FLOOR DRAIN DR SURFACE COLLECT! ON UN IT EQUIPMENT DRAIN 2
DUCTWORK IDENTIFICATION REV.
DATE RAWN 1
st24t9o S B R CHKD. SUPV. APPD.
RBF HLP N/A REDRAWN FOR CLARITY &
INCORP.
DEC-421 REV.
DATE RAWN 2
092493 DJ B CHKD. SUPV. APPD. H RBF T JM N/A INCORP.
LINE !DENT IF !CATION NUMBER WILL BE AS FOLLOWS:
RFR-14139A PLANT UNIT NO J
~-SYSTEM DESIGNATION 2-GE-107
-~
L___ SEQUENCE NO ADDITIONAL INFORMATION SUCH AS DUCT CLASS & SIZE WILL BE ADDED AS FOLLOWS:
2-GE-107-5NK-60"
-~ --
DUCT CLASS --
L___ SIZE -ROUND EOU I VALENT DUCT DIAMETER IN INCHES G
GENERAL NOTES 1-LINE NUMBERS AND SYSTEM DESIGNATORS WILL BE ASSIGNED IN ACCORDANCE WITH STANDARD ENGINEERING DEPARTMENT PROCEDURES.
2-UNIT NUMBER AND SYSTEM DESIGNATOR WILL APPEAR IN THE P&ID TITLE BLOCK AND NOT BE REPEATED ON THE LINES.
3-DUCTWORK AND DAMPER CLASSES ARE DESIGNATED BY A THREE CHARACTER ALPHANUMERIC CODE. THE FIRST CHARACTER INDICATES THE DUCT PRIMARY PRESSURE RATING THE SECOND CHARACTER DESCRIBES THE MATERIAL AND THE THIRD INDICATES APPLICABLE STANDARDS.
FIRST CHARACTER-PRIMARY PRESSURE RATING
- 2. LESS THAN -13" W.G.
- 3. -12 3// W.G.
TO -7"
- 4. -6 31411 W.G.
TO -4 1'
- 5. -3 31411 W.G.
TO +3 314"
- 6. +4" W. G.
TO +6 3,/
- 7. + 7" W. G.
TO +1 2 3,/
- 8. GREATER THAN +13" W.G.
SECOND CHARACTER-MATERIAL B-CARBON STEEL C-AUSTENITIC STAINLESS STEEL E-ALUMINUM N-CARBON STEEL, GALVANIZED TOTAL PRESSURE TOTAL PRESSURE TOTAL PRESSURE TOTAL PRESSURE TOTAL PRESSURE TOTAL PRESSURE TOTAL PRESSURE IFOR ADDITIONAL TYPES OF MATERIAL REFER TO DRAWING M-220102)
THIRD CHARACTER-APPLICABLE BECHTEL POWER CORPORATION HVAC DUCTWORK STANDARDS K-STANDARD CONSTRUCTION L-GAS TIGHT WELDED CONSTRUCTION M-SEISMIC CATEGORY 1 CONSTRUCTION, INCLUDING HANGER AND SUPPORTS N-SEISMIC CATEGORY 1 CONSTRUCTION. HANGERS AND SUPPORTS ONLY P-SEISMIC CATEGORY 1 CONSTRUCTION, INCLUDING HANGERS AND SUPPORTS OF GAS TIGHT WELDED DUCTWORK R-SEISMIC CATEGORY 1 CONSTRUCTION, HANGERS AND SUPPORTS ONLY. FOR GAS TIGHT WELDED DUCTWORK S-DUST OR MATERIAL HANDLING DUCTWORK F
E 4-SYMBOLS SHOWN ON THIS DRAWING CAN BE USED IN A PIPING D
ORTHO. DRAWING AND IN ISOMETRIC FORM ON PIPING ISOMETRIC DRAWINGS.
AS-BUILT REV.
DATE DRAWN 3
01029 RL W CHKD. SUPV. APPD.
DLBc AMR N/A INCORP.
DEC-1312.
REV.
DATE 4
041905 DRAWN CHKD. SUPV.
MAL RL W TWS INCORP.
RFR 22941A CLASS 1 c
B DRAWN
<DATEI SYMBOLS AND LEGEND A
N/A N/A REF.
1-c,=,wc-. -=,,.=,, FOR SYSTEM FLOW AND NOTE N/A N/A pIpING AND
~
tc,=upv~. --~"'='" INSTRU~ENTATION DIAGRAMS~
N/A N/A rFSAR FIGURE 1.1 1 SHEET 3""
APPO.
(OATEJ LOCATION N/A N/A UNION ELECTRIC COMPANY ST. LOUIS, MD CALLAWAY PLANT M-220103 1
CLASS REV.
4