Isotope Kr 85 Kr 85m, 87, 88 Xe 133 TABLE 11.3-1 (H~storical Informat~on)

ESTIMATED ANNUAL GASEOUS RELEASE BY ISOTOPE(!)

FROM GAS DECAY TANKS

{Per Unit)

Activity Release to Environment Curies/yr Xe 133m, 135, 135m 138 5450 Negligible 2000 Negligible Total 7450 NOTE:

(1)

Based on 1 percent defective fuel, 3423 MWt core, load follow and 45 days holdup.

1 of 1 SGS-UFSAR Revision 19 November 19, 2001 I

Isotope H-3 Kr-85 Kr-85m Kr-87 Kr-88 Xe-133 Xe-133m Xe-135 Xe-135m I-131 SGS-UFSAR TABLE 11.3-2 (Histori.ca:t Information}

ESTIMATED TOTAL RADIOACTIVE GASEOUS RELEASES

{TWO UNIT BASIS}

Estimated Annual Release (Curies) 248 11450 195 113 309 26850 240 633 10 0.23 1 of 1 Revision 19 November 19, 2001 I

Annual Isotope Release (Curies)

H-3 248 Kr-85 11450 Kr-85m 195 Kr-87 113 Kr-88 309 Xe-133 26850 Xe-133m 240 Xe-135 633 Xe-135m 10 I-131 0.23 Totals 401000 NOTES:

(1) gamma energy (2) beta energy SGS-UFSAR TABLE 11.3-3 (Historical Information)

ESTIMATED OFF-SITE RADIATION EXPOSURES GASEOUS RADIOACTIVE RELEASES (Two Unit Basis}

Radiation ExEosure (mrem) at 1270 Meters, North Sector Finite Cloud*

Semi-Infinite Cloud(1)

Infinite Cloud(2)

Whole BodY: Dose Whole BodY: Dose Skin Dose

{rnrem)

(mrern)

(mrem) 0 0

0.0007 0.0033 0.012 1.12 0.0039 0.008 0.023 0.0059 0.046 0.073 0.058 0.15 0.053 0.227 0.55

1. 94 0.0062 0.0016 0.023 0.017 0.042 0.087 0.0003 0.0011 0.0004 negl negl negl 0.269 0.81 3.32 1 of 1 Revision 19 November 19, 2001 I

TABLE 11.3-4 (Historica1 Information)

POTENTIAL RADIATION EXPOSURE PATHWAYS TO MAN {GASEOUS}

Pathway External Exposure Ingestion of Milk SGS-UFSAR Individual Assumed Exposed Individual stands at nearest site boundary 100 percent of time Young child drinks entire intake of milk from nearby dairy farms.

Cows assumed to graze 9 months per year with grass making up to 100 percent of diet during that time.

1 of 1 Calculated Exposure 0.054 rnrem/yr

{whole body-finite cloud) 0.16 rnrem/yr (whole body-semi - infinite cloud}

0.66 rnrem/yr (skin - infinite cloud, beta energy only}

0.26 rnrem/yr (farm 4.1 miles NW of site)

Revision 19 November 19, 2001 I