2.3 METEOROLOGY 2.3.1 Regional Climatology 2.3.1. 1 Data Sources Data sources are listed in the references provided at the end of this section.

2.3.1.2 General Climate Based on the Koeppen climatic classification system, the region intersects two climatic zones.

They are humid continental and humid sub-tropical.

Both zones have characteristics of warm summers and mild winters (1). Summer maximum average temperatures are near 80 degrees Fahrenheit, and the coldest month is January having an average daily temperature of approximately 32 degrees Fahrenheit.

Examining a 30 year mean of precipitation amounts for Wilmington, Delaware, National Weather Service (NWS) station shows that the most rainfall occurs in the summer months, followed by spring, fall, and winter (2).

The area of southern New Jersey is frequented by Polar Canadian air masses in the fall and winter and occasionally invaded by Arctic Canadian air late in winter.

During the spring and summer, the dominant air mass is Maritime Tropical (1).

2.3.1.2.1 Precipitation The frequency of precipitation events such as rain, snow, ice storms, thunderstorms, and hail are tabulated in Tables 2. 3-1, 2.3-2, and 2.3-3.

The data in Table 2.3-1 were obtained from the Revised Uniform Summary of Surface Weather Observations, Dover (Delaware) Air Force Base, 1942-1965.

The data presented in Tables 2.3-2 and 2.3-3 were obtained from Philadelphia International Airport and Trenton Airport, respectively.

2.3-1 SGS-UFSAR Revision 6 February 15, 1987

2.3.1.2.2 Humidity, Winds Humidity annually averages 70 percent (3).

Prevailing winds on a monthly average during the winter (December to March) are from a northwest direction with a range of speeds from 9 to 13 mph.

Average monthly winds for the spring and summer months (April to August) are from a southerly to southwesterly direction at speeds ranging from 7 to 10 mph.

Winds during the fall are predominantly from the west-southwest veering to a west-northwest direction by December.

The average wind speeds increase as the season progresses (4).

2.3.1.3 Severe Weather The terrain is open and extremely flat which favors a vigorous wind flow.

While the area is almost certain to experience hurricane force winds frequently, there is no reason to anticipate fastest mile velocity, reaching 100 miles per hour, more than once in 100 years.

Table 2.3-4 lists the distribution of peak winds for Philadelphia International Airport based on a 25-year record.

The tornado frequency in this area is reassuringly low; a few small funnels have been observed in southeastern Pennsylvania and southern New Jersey, but it is unlikely that any tornado would affect the site itself more than once in 4300 years.

2.3.2 Local Meteorology Figure 2.3-1 shows the different stations that collect meteorological records.

Figures 2.3-2 and 2.3-3 are 2-year wind roses derived from Artificial Island wind data using all hours and only hours with a stable stability, respectively.

The wind direction is randomly distributed when stable atmospheric conditions occur, whereas using all hours of data shows a

northwest wind direction peak.

2.3-2 SGS-UFSAR Revision 6 February 15, 1987

2.3.3 Onsite Meteorological Measurements Program Meteorological Data Collection Program In order to arrive at atmospheric dispersion factors for use in calculating radiological exposures from both low level normal releases and accidental releases, an extensive data collection program was undertaken at the site.

This data collection program is described in detail in the following paragraphs.

The present meteorological monitoring program is in conformance with the recommendations of Regulatory Guide 1.23.

2.3.3.1 Preoperational Data Collection Program Data became available from the 300 feet meteorological tower located on Artificial Island in June of 1969.

The official preoperational data collection program was terminated at the end of May 1971.

The tower was positioned just north of the actual plant site and is shown on Figure 2.3-1.

The actual location was 2700 feet north of Unit 2 at a Latitude of 39 degrees 28 minutes 13 seconds north, and a Longitude of 75 degrees, 32 minutes 12 seconds west.

A detailed representation of the meteorological facility is not necessary because of the simplicity of the terrain.

The tower data used in this study is primarily that from the 33 and 300-foot levels, although some data were obtained at the intermediate 150-foot elevation.

The wind instrumentation consisted of Aerovanes, and the temperature-difference measurements were obtained from aspirated resistance thermometers.

The usual precipitation, humidity, and solar radiation are on record if they are ever needed for general environmental applications.

2.3-3 SGS-UFSAR Revision 6 February 15, 1987

2.3.3.1.1 Data Summaries and Turbulence Classifications The record of temperature and all other data extends from June 1969. Data are being obtained continuously.

A monthly distribution is presented in Table 2.3-5.

Table 2. 3-6 shows monthly summaries of precipitation in inches for June 1969 through November 1970.

Included with this summary is a range of maximum hourly rates.

Table 2.3-7 lists the monthly percentages of hours with fog in 3-hour intervals.

October through March have the largest percentage of fog during the hours of 0600 to 0800.

During April through September, the largest percentage occurred between the hours of 0300 to 0500.

Stability Alternative techniques of estimating the turbulence usually involve one of two methods:

approximating it from a combination of lapse rate and 'tJind speed measurements, or from the fluctuations of a standard wind instrument such as an Aerovane.

We believe the latter to be more representative of the typical

~Lvu~~m~, and accordingly this is based on wind direction range and data.

The rate classification has been used, however, and some of the data are summarized in the report.

In this the two techniques are in good Turbulence Classifications The system used for defining the turbulence is that developed originally by Singer and Smith(5) and widely applied in both nuclear and fossil power plant evaluations.

The classification is depicted on Figure 2. 3-4, where Classes I and II unstable conditions.

SGS-UFSAR 2.3-4 Revision 25 October 26, 2010

Class III is the overcast stormy situation, and Class IV is the stable, inversion flow pattern.

In the Preliminary Safety Analysis Report the distribution of turbulence classifications obtained from the Delaware City site 10 miles north-northwest of Salem, was presented as probably typical of the dispersion regimes.

In Table 2.3-8 the new Salem data (300-foot level) are compared with the earlier summary from Delaware City, and the agreement is very good despite the fact that the information was obtained in different years.

The only notable difference is that Salem showed a more marked tendency toward the neutral Class III turbulence than did Delaware City.

This aberration may be real, but it is more likely that the water tower on which the Delaware City instrument was located produced somewhat broader and more turbulent direction traces than the clean installation at Salem.

In any case, the difference has no great significance in the dispersion evaluation.

At both sites, the distributions seem quite normal for open, mid-latitude locations.

The Class II turbulence dominates the distributions, accounting for approximately 60 percent of all hours, and the stable cases are found in roughly 25 percent of the remainder.

We had anticipated a noticeable increase in the frequency of Class IV conditions during the late spring and early summer at Salem, because it is directly exposed to over-water flow which might be

stable, but apparently the combination of infrequent winds from the 130-to 160-degree sector and the relatively mild bay temperatures did not produce the expected increase.

Lapse Rates In Table 2.3-9, the distribution of lapse rates over the year is shown.

These data agree well within the indications of the turbulence classification, in that 24 percent of the hours appear to be stable, 14 percent neutral, and the remainder unstable.

2.3-5 SGS-UFSAR Revision 6 February 15, 1987

Another indication that the water influence is fairly small at this site is that the diurnal variation of the lapse rate in June (Figure 2.3-5) does not show any tendency toward stability in the afternoon hours, and, in fact, is quite similar to the December (Figure 2.3-6) pattern.

Relation Between Lapse Rates and Turbulence Classes As a final comparison between turbulence classes and the lapse rate data, Table 2.3-10 is presented which clearly shows that the two methods of estimating turbulence are compatible at this site.

The vast majority of Class I and Class II turbulence hours are associated with unstable lapse rates, and the Class IV hours are primarily inversion periods as they ought to be.

The distributions of lapse rates, winds, and turbulence classes already presented are adequate to define the diffusion meteorology of this site as quite normal and uncomplicated, but it is important to translate the data as accurately as possible into the dispersion parameters actually used in numerical evaluations.

Since the experience with the bi-directional wind vane was typically unsuccessful, the measurement of hourly wind direction range was evaluated and used for estimates of ae.

These data, separated according to turbulence class, are given for the entire period of observation in Table 2.3-11, and it is apparent that the wind fluctuations at this site are very nearly identical to those at Brookhaven National Laboratory (6) where the turbulence classification was originally developed.

It therefore is reasonable to utilize the diffusion parameters developed at that site (7) in this study.

One further point is important, and that is to be sure that diffusion with south-southeast winds from the open waters of Delaware Bay is not significantly different from that occurring with other wind directions. Table 2. 3-12 is a replica of Table

2. 3-11, except that only south-southeast winds are represented.

Obviously there is no difference.

2.3-6 SGS-UFSAR Revision 6 February 15, 1987

Hour-by-hour stability frequency tables are presented in Tables 2.3-9 and 2.3-10.

The distribution of wind speeds at the 33-and 300-foot levels as a function of turbulence class are presented in Table 2.3-13, where the most notable feature is the very low frequency of calms.

Normally, with an Aerovane as a sensing instrument, calms at the 33-foot elevation are prominent, but the very flat terrain and the air-sea interaction at Salem obviously favor a vigorous wind flow.

Also, the percentage of hours having relatively high speeds, reflected in both Tables 2.3~13 and 2.3-14, is quite large, as one would anticipate in this locality.

Data recovery percentages for the June 1969 to May 1970, 33-foot and 300-foot wind data, are shown in Table 2.3-15.

2.3.3.2 Operational Data Collection Program The digital Meteorological Data Acquisition Systems provide increased data recovery over traditional systems.

The digital Meteorological Data Acquisition systems were designed to meet the intent of Regulatory Guide 1.23.

The Salem and Hope Creek Safety Parameter Display System ( SPDS) 1 provides an Artificial Island wide source of 15-minute average meteorological monitoring system parameters, which are read from the two digital data acquisition systems.

The parameters available for display are 33-ft wind speed, direction, sigma theta, and horizontal stability class; 150-ft wind speed, direction, sigma theta, and horizontal stability class; 300-ft wind speed, direction, sigma theta, and horizontal stability class; delta temperature between 300 and 33-ft; delta temperature between 150 and 33-ft; vertical stability class for each delta temperature; precipitation; barometric pressure; solar radiation; and ambient and dew point temperatures.

2.3-7 SGS-UFSAR Revision 23 October 17, 2007

transport and Dose and diffusion is calculated by Assessment System (MIDAS) computers the Meteorological installed in both Salem and Hope Creek.

A method for determining atmospheric transport and di the plume exposure emergency planning zone during emergency conditions has b~en developed.

The system became operational in April 1976.

The location of the 300-foot guy wire supported tower is Latitude 39 degrees, 27 minutes, 48.9 seconds, North and Longitude 75 degrees, minutes, 11.76 seconds, West.

The data collection program also includes an additional tower, identified as a backup meteorological tower, consisting of a 1 0-meter telephone pole.

The backup tower is located approximately 500 feet south of the primary meteorological monitoring tower.

Backup meteorological data provides wind speed, wind direction, and a computed sigma theta.

Wind speed and direction instruments are located at 300-foot, 150-foot, and 33-elevations on the primary tower and at the 33-foot elevation on the backup tower.

Temperature measurement includes ambient taken at the 33 foot elevation and temperature differences taken between T300 -

T33 and T150 -

T 33 levels.

Temperature sensors consist of thermistors in a motor aspirated solar radiation shield.

The dew-point is measured at the 33-foot level.

Rainfall and barometric pressure are measured at approximately 3 and 6 feet, respectively.

Figure 2. 3-7 depicts the heights of these instruments on the tower.

2.3-8 SGS~UFSAR Revision 21 December 6, 2004

All meteorological parameters are electronically recorded in the Meteorological Instrument Building at the base of the tower, The data acquisition system includes capabilities for remote interrogation in addition to data acquisition.

The data acquisition systems consist of primary and backup data acquisition systems (DAS) located at the Meteorological Instrument Building.

A diagram of the system configuration is provided on Figure 2.3-8.

The rain gauge uses a tipping bucket.

The primary and backup DAS are configured with identical hardware.

Each DAS is provided with communication ports, including one as a link to the Salem and Hope Creek SPDS, and one for direct dialup capability.

Each DAS provides storage for at least 7 days of 15-minute averages.

The primary DAS collects wind speed and direction from the primary tower.

The backup DAS collects wind speed and direction from the backup meteorological tower.

Each DAS calculates a sigma theta for its respective meteorological tower (each of the three level wind directions on the primary tower, one level on the backup tower).

The host computers acquire the meteorological data collected by the data loggers.

2.3-9 SGS-UFSAR Revision 23 October 17, 2007

The calculations of the sigma thetas use samples of horizontal wind direction at each elevation/location.

Data interrogation :i.s possible through dial-up connection to the digital data acquisition systems, which also prov:l..de data to the Salem and Hope Creek SPDS.

'l'he SPDS supports display units in the EOF, the Hope Creek Control Point, the Salem and Hope Creek TSCs, the Hope Creek OSC, and the Salem Ops Ready Room.

Additional sources of meteorological data to provide a description of airflow trajectories from the site out to a distance of 50 miles include Wilmington and Philadelphia National Weather Service (NWS) stations.

Hourly wind, NWS stations.

SGS-UFSAR temp>er*at:ux:e, and cloud cover data are readily available from these 2.3-10 Revision 23 October 17, 2007

2.3.4 Short-Term Diffusion Estimate 2.3.4.1 Objective The objective is to provide conservative and realistic short term estimates of relative concentration (X/Q), at both the site boundary and the o~ter boundary of the low population zone (LPZ) following a

hypothetical release of radioactivity from SGS Units 1 or 2.

The assessment is based on the results of atmospheric diffusion modeling and onsite meteorological data.

2.3-11 SGS-UFSAR Revision 18 April 26, 2000

A ground-level accidental radionuclide release from SGS is analyzed at various distances.

Conservative and realistic X/Q values at the exclusion area boundary (EAB) are derived for the 0- to 2-hour period following a postulated accident.

Conservative and realistic estimates of the X/Q value at the outer boundary of the LPZ are computed for 2, 8, 16, 72, and 624 hours0.00722 days <br />0.173 hours <br />0.00103 weeks <br />2.37432e-4 months <br /> following a postulated accident. For this modeling assessment, the EAB is a distance of 1270 meters in all sectors except the Northeast and East, which were 1391 meters.

The LPZ boundary is 5.0 miles (8,047 meters), all sectors.

2.3.4.2 Accident Assessment The short-term, 0-to 2-hour X/Q values for ground-level releases are calculated with the sector dependent model described in Regulatory Guide 1.145, Reference 8.

Annual accident X/Q values are also required to derive the intermediate time period X/Q values.

These annual accident X/Q values are derived using the long-term diffusion model described in Regulatory Guide 1.111, Revision 1, Reference 9.

2.3.4.2.1 Methodology The procedures used to estimate the X/Q values for the appropriate time periods following a postulated accident are described in Regulatory Guide

1. 145.

The diffusion model generates a cumulative frequency distribution of X/Q values for each sector-distance combination representing the first 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after the postulated accident.

These 2-hour X/Q values are based on 1-hour averaged data, but are assumed to apply for 2

hours.

The frequency distributions are plotted on a log-probability scale for each sector-distance combination, and are then enveloped in accordance with the methodology described by Markee and Levine in Reference 11.

The X/Q value that is equaled or exceeded 0. S% of the time at each sector-distance combination is then determined from the intersection of the envelope and the 0.5'-

probability level.

The highest sector dependent X/Q value is then compared with the "overall" St accident X/Q value.

The highest value represents the conservative 2-hour accident X/Q. The realistic 2-hour accident X/Q is evaluated at the overall 50% probability level.

The overall 5% and 50% X/Q values are determined by summing the sixteen sector dependent X/Q distributions for each distance into a curnulati ve frequency distribution representJ.ng all sectors and again enveloping the data points.

The 5% and 50% values are determined by the intersection of the envelope with the 5% and 50% probability levels, respectively.

2.3-12 SGS-UFSAR Revision 16 January 31, 1998

The conservative accident X/Q values for time periods of up to 30 following an accident are derived by logarithmic interpolation between the 2-hour 0.5%

and the annual accident X/Q value at each sect6r-distance combination.

The intermediate time periods for the overall 5% and 50% X/Q are determined by logarithmic *interpolation between the overall 2-hour 5% and 50% X/Q values and the maximum annual X/Q.

The maximum conservative X/Q value for a given distance is the maximum sector 0.5% X/Q, or the overall 5% X/Q, whichever is higher, for the conservative assessment. The realistic assessment is based upon the overall X/Q and the overall 50% X/Q.

The higher X/Q.value is chosen again.

2.3.4.2.2 Meteorological Data 2.3.4i2.2.1 Representativeness The

  • Artificial Island meteorological tower data from January 1988 through December 1994 are employed in the accident assessment.

The data collected at the tower are representative of the meteorological conditions under which effluents are released, since both are located on the Delaware River shoreline.

Furthermor~, the proximity of the 300-foot tower to SGS ensures.that the data are representative of the conditions used in an accident evaluation.

2.3.4.2.2.2 Joint Frequency Distributions Joint stability class and direction distributions of wind speed and direction by atmospheric are used as input to the diffusion calculations.

Wind speed data from the 33-foot level are used in the assessment of diffusion for the ground-level releases.

Atmospheric stability is determined for the 33-foot distributions by the difference between the 300-and 33-foot levels. Joint frequency distributions of wind speed and direction by atmospheric stability class are computed for 22.5° sector using the wind speed groups and atmospheric stability classes suggested in Regulatory Guide 1. 23.

The 7-year frequency distributions are used in the SGS-UFSAR

2. 3-13 Revision 16 January 31, 1998

With the exception of the calm and 25+ mph wind speed groups, the highest wind in each group is used to represent that group in the diffusion calculations.

For conservatism, a wind speed of 0.5 mph is used to represent calms at the 33-foot level.

This value represents a conservative threshold wind speed for the 33-foot wind instrumentation.

Due to the high wind speeds asso~iated with this site, a wind speed of 30 mph is used to mph wind speed group.

the 25+

2.3.4.3 Atmospheric Diffusion Model The ~eactor building vent is treated as a ground-level source for both short-term and long-term calculations.

This implies that no plume rise is calculated and no terrain corrections are applied.

A building wake correction factor is used, in accordance with the methodology discussed in Regulatory Guide 1.145 for vent releases.

The building wake correction factor takes into account the initial mixing of the plume within the building cavity.

The vent release X/Q values are calculated with the following equations from Regulatory Guide 1.145:

X/Q =

X/Q X/Q 1

where:

X/Q relative concentration, s/m3 U10 wind speed at the 10 m level, m/s

2. 3-14 SGS-UFSAR (2.3-2)

(2.3-3)

(2. 3-4)

Revision 21 December 6, 2004

Sy

  • lateral plume apeed, m

~ =

lateral plume spread with meander and building wake effects, m sz =

vertical plume spread, m A =

smalleat vertical-plane cross-sectional area of the reactor building, and adjacent structures, m2

  • 2 A building wake correction factor of 2430 m is used for calculations of the short-term X/Q.

For neutral or stable conditions combined with wind speeds less than 6.0 mjs, calculations of the X/Q value& are made using Equations 2. 3-2 through 2. 3-4. For all other meteorological conditions, X/Q values are calculated using Equations 2.3-2 and 2.3-3 only.

The values computed from Equations 2.3-2 and 2.3-3 are compared, and the higher value is selected. For neutral and stable conditions with a wind &peed less than 6 mjs, the value from Equation 2.3-4 is compared with the value chosen from Equations 2.3-2 and 2.3-3, and the lower value is chosen to represent these conditions.

2.3.4.4 Diffusion Estimates 2.3.4.4.1 Exclusion Area Boundary

-4 3

The maximum conservative 2-hour X/Q at the EAB, 0.79 miles, is 1.30 x 10 s/m

  • This is the maximum overall 0.5% sector dependent value at this distance. This value is larger than the overall 5% X/Q value.

The maximum realistic (50\\) 2-

-S 3

hour X/Q at the EAB is 3.0 x 10 s/m

  • This is the overall SO% X/0, value.

Conservative and realistic X/0, values for the EAB (0.79 miles) for all the time periods following the accident are given in Table 2.3-21.

2.3.4.4.2 Low Population zone The maximum conservative and realistic X/0, values, 0.5\\ and SO\\, respectively, given in Table 2.3-21 represent the maximum X/0, value& (sector value used if greater than the overall value) at the LPZ boundary, 5 miles.

2.3-14a SGS-UFSAR Revision 16 January 31, 1998

2.3.5 Long-Term Diffusion Estimate 2.3.5.1 Objective The objective is to provide realistic estimates of annual average offsite atmospheric dilution factors based on site meteorological data.

2.3.5.2 Calculations Annual X/Q values for sixteen -

22. 5 -degree arcs at sixty distances are presented in Tables 2.3-17 through 2.3-20.

The meteorological input data used was the 2-year period, June 1969 2.3-14b SGS-UFSAR Revision 16 January 31, 1998

through May 1971.

X/0. estimates are based on the procedures presented in Regulatory Guide 1.111. These values were submitted in July 1976 as part of the Appendix I, 10CFRSO submittal to the NRC.

2.3.6 References for Section 2.3

1.

Chritchfield, Boward J. "General Climatology," Englewood Cliffs, N.J.

(Prentice Ball Inc.) pp. 148-151, 1966.

2.

Wilmington, Delaware Local Climatological Data, u.s.

Department of Commerce, 1980 ad.

3.
4.

u.s. Department of Commerce.

170-175, June 1968.

u.s. Department of commerce.

228-234, June 1968.

5.

DELETED

6.

DELETED

7.

DELETED "Weather Atlas of the united States," pp.

"Weather Atlas of the United States," pp.

8.

U.S. NRC "Atmospheric Dispersion Models For Consequence Assessments at Nuclear Power Plants," Regulatory Guide 1.145, Rev 1, Nov. 1982

9.

u.s. NRC "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors,"

Regulatory Guide 1.111, Rev 1, July 1977

10.

Meteorological Evaluation Services Co., Inc., "Accident X/0. Values at the Salam Generating Station Control Room Fresh Air Intakes, Exclusion Area Boundary and Low Population Zone," April 1996

11.
Markee, E.B.

and J.R.

Levine, 1977, "Probabilistic Evaluations of Atmospheric Diffusion Conditions for Nuclear Facility Design and Siting,"

in proceedings of the American Meteorological society conference on Probability and Statistics in Atmospheric Sciences, Las Vegas, Nevada, pp.

146-150 2.3-15 SGS-UFSAR Revision 16 January 31, 1998