1 to Updated Final Safety Analysis Report, Drawing E-0064B Index, Rev 76, Sheet 0003
ML17045A391
Person / Time
Site: Davis Besse 
Issue date: 11/21/2016
From:
Bechtel Company, FirstEnergy Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17039A594 List: ... further results
References
L-16-322 E-0064B, Rev 76
Download: ML17045A391 (1)


Text

NEWf:AX 3/85 N58313 ED 7489 INDEX (CONTINUED)

EQUIPMENT (LOCATION) NUMBERS (CONTINUED)

SHEET LATEST DESCRIPTION SCHEME NO.

REV.

NO.

BE t 263 <BF 1263>

480V MCC Et2B (F128) STARTER 26C 4

STATION BLACKOUT DIESEL GENERATOR BRKR AD301 AD301 MCO l t 1 C MC 0112 >

EMERG. OG STARTING AIR CMPSR 1-1 Ct-2) MTR CONTROL ANO TRIP BE 1261 <BF I 26 tJ 480V MCC E128 CF128) STARTER MP1471 <MP1472>

EMER OG 1-l (1-2> SOAK-BACK PUMP 27 2

SBO DIESEL GENERATOR SBO D.G. BLDG. SUMP PUMPS & CONTROL BFS 115 BE t 258 CBF 1258) 480V MCC E-128 <F12B> CONTACTOR BF 8116 FPSL-3751AC8)

EMER. DG 1-1 (1-2) AIR INTAKE 28A 0

STATION BLACKOUT DIESEL GENERATOR BLDG. ELECT.

BF 8112 FPSH-3752A(8)

EMER. DG 1-1 <l-2> AIR EXHAUST EQUIPMENT ROOM VENT. FAN (C153) CONTROL LTE5329 t36)

EMER. DG l-1 <l-2> RM TEMP MV5329A,B,C EMER. OG 1-1 RM SUPPLY FANS 288 1

STATION BLACKOUT DIESEL GENERATOR BLDG. ELECT.

L34226 MV5336A,8,C EMER. OG 1-2 RM SUPPLY FANS EQUIPMENT ROOM M.O. LOUVER (CV6004 & CV6005) CONTROL MV3611A,B,C EMER. OG STARTING AIR CMPSR Ctt-1 MOT. ACTUATED VALVES 29A 0

STATION BLACKOUT DIESEL GENERATOR BLOG. D.G. ROOM BF8113 MV3612A,B,C EMER. OG STARTING AIR CMPSR cit-2 MOT. ACTUATED VALVES VENT FAN 1 <Ct52-1) CONTROL MV3613A,B,C EMER. OG STARTING AIR CMPSR C1t-3 MOT. ACTUATED VALVES 298 2

STATION BLACKOUT DIESEL GENERATOR BLDG. D.G. ROOM L34220 M.O. LOUVER (CV6001 & CV6002) CONTROL 30A 0

STATION BLACKOUT DIESEL GENERATOR BLOG. O.G. ROOM BF 114 VENT FAN 2 (C152-2) CONTROL 308 2

STATION BLACKOUT DIESEL GENERATOR BLDG. D.G. ROOM L34222 M.O. LOUVER (CV6000) CONTROL 31 1

STATION BLACKOUT DIESEL GENERATOR BLOG.

BF8101 THRU MISC. CABLE BLOCK DIAGRAMS BF8107 32 1

SBO DIESEL GENERATOR BLDG.

BF8108 THRU BF8111, MISC. CABLE BLOCK DIAGRAMS BF 8 I 17, BF 8 I 18 33 3

SBO DIESEL GENERATOR BLDG. MISC. CABLE BLOCK DIAGRAMS SEE SHT.

34,M STATION BLACKOUT DIESEL GENERATOR BLOG.

OG300 MISC. CABLE BLOCK DIAGRAMS INC. OCN' S E-648-441 & 443 PER ECR 03-0444-00 AND REV I SEO SH. 7 (REV. 13), SH. 7A (REV. 1) & SH.12 (REV.5) & GEN UPDATE SHEET 12 NOT SHOWN DELETED (VOID). REVISED TO B-25-08 REMOVE BE1299 & BF1263, FOR MCll-1& MCtt-2 PER OCN REVIEW. SH. 12 WILL BE SHOWN VOID "INTI rALS ON *1LE 11 71 WHEN DCN'S E-648-444 (FOR lNDEX) AND OCN E-648-447 (SH.12) ARE POSTED AS-BUILT FOR MC11-3 (BE2342) COMPRESSOR WORK. (DWG. UPDATE REO'D. FOR SH.12, 3 OCN, 90 DAY CLOCK) 70 2-4-08 REVISED SH.IE (REV. 19), SH. 1G lREV. JO), SH. IH (REV.2), SH. 7 (REV.12),

II INTI PALS ON.. ILE" THIS DRAWING WAS REDRAWN ON CAO AND SUPERSEDES REVISION 65.

SH. 14 (REV.8) & SH.25C (REV.2)

.. 76 3>.; 6-ts REVISED SH. toe (REV. 7) & SHT's 19 & 34 (REV.2) s~w ~tvJ L...A...r> -

'MZX -

SCALE NONE I DESIGNED I

DRAWN JOR I

DATE 04-26-04 fa\\

75 11-4-11 REVISED SH.tA (REV. 13), SH.7 lREV. 14), SH.7A (REV. 3), SH'S 25A 8c 26A (REV. 4J II INTI IALS ON

  • rLE" DAVIS-BESSE NUCLEAR POWER STATION

& SH. 31 (REV. 1) 74 5-14-10 REVISED SH. 1A (REV. 12), SH.IE (REV.21), SH. IF (REV.15), SH. tG & SH.2F II INTI lALS ON

~ILE 11 UNIT NO. 1 (REV.ll), SH.tH (REV.3), SH.2A <REV.14), SH.2E <REV.19) 8c SH. 19 <REV.I)

THE TOLEDO EDISON COMPANY 73 12-21-09 REVISED SH. 2C (REV. 10), SH. 7A (REV. 2) & SH. 248 (REV. 2)

"INTI.ALS ON ::-rLE" ELEMENTARY WIRING DIAGRAMS Q

INC. DCN E-648-444 PER ECR 03-0444-00, REVISED SH. IE (REV.20), SH.2E <REV. 18>, SH.12 EMER DSL GENS 72 3-03-09 (REV.6>, SH'S.22 & 26C) (REV.4), SH'S. 25A 8c 26A (REV.3), ~ SH.268 (REV.5) & GEN.

II INTI ALS ON qLE 0

DRAWING INDEX UPDATE SHOW SH. 12 AS *oRAWING VOIOu PER REVIEW OF OCN E-648-440 & DRAFTING PRACTICE DRAWING NO.

REV.

REV DATE DESCRIPTION BY CH 1 K, ENGR.

ENGR.

GEN.

E-648 SH.3 76 SUPV.

SUPV.

DB 11-21-14 OFN:/F/SCHEME/E64BINO.OGN