NEWf' AX 3/85 N58313

\\

!5 w

z

=

~

,J - --ii>

U-LL-

\\a) z:!s

z z: z: WCI)

" 0 0

0 V")

C./)

V')

~

--' --' _J o<(

<C <

z

z :z :z

~

~

= = 5

=-~

~

co 0

  • 0...

0...

0 0

V>

I

~ (,D 0

C>

N C>

0 C>

I I

U">

C>

0 O")

0:::

0 u

0 LLJ

E:

a::

0:::

L&J 0

0.. U-co "="'

0 q-(Fl r-I I

cc:i a:i N

N LO l.O I

I LLJ LJJ

z: z u

(...)

c 0

(..) <..>

z:.z ED 7489 s.u.

WIRE EOUIPMENT NUMBERS DESCRIPTION SCHEME MCC NO. CHANNEL PREFIX cs MA c

co B

E M

N SA1 SA2 SA3 SA4 KA KB KC KO BF 1142 F 110 49 2

SLB HISDH09A MVOH07A C5716 CDFtlC BFt 142 EVDH09A MVOH09A NVDH09A I "'If "'1"'111 r "'If "'lr..1 K:tK E K :IX E CTMT EMER OUT VALVE A I :"I /"'i"\\I l:"I ("lhU K"'il A K"i1 A BE t t 12 Et tA 49 1

SLA H1SOH09B MVOH078 C5716 COE I IA BEt 112 EVDH098 MVOH09B NVDH09B

..,..l"\\.#11 r O\\Jf\\'\\1-K7K A K7X A CTMT EMER OUT VALVE B I :"I th71 I "I lh'\\11 K"'il A K"il 4 Bf It 48 F 118 49 2

BWB HISDH07A MVDH09A C5716 CDf 118 BF 1148 EVDH07A MVDH07A NVDH07A

('."\\ f'\\"\\IJ r:"i '"toil K'/K G K'/X G BWST 1-l OUT VALVE A I:'°"('\\'\\(

I "I f"lhll K51 R K5\\l H BE 1157 El lA 49 1

BWA HISOH07B MVDH09B C5716 COE I IA BE 1157 EVOH07B MVOH07B NVDH07B l :... (h:/IJ

( -"' fh_'\\l K7K G K7X {j BWST 1-1 OUT VALVE 8 I "> lt'o./I

("O\\ (h'\\11 K"i. I R K~1 H COMPUTER INPUTS THROTTLE INTERLOCKS CNOTE 1>

TR t, TR t I, CL 1, CL 11 R,G,WOt

<A>

(H)

Xl,XA,XB,TR,TR21 CL,Cl21,R1,Gl,WO co (G)

SPLICE CF> IN Ft 1C CL2,CL TR41, TR31 A3C4 At<2 CL,CL2,CL3 CL41,TR21,TR2 TR31.TR41 TR41,Xt

[__PREFABRICATED CABLES~

c TR t, TR 11, CL 1, CL 11 R,G,WOI

<A>

'---y--/

(Zt031

<ZS-DH7A>

XI, TR41, TR, TR21 TR 31, CL 21, Cl, CL 2 CL 41, R 1, G 1, WO (8)

SPLICE IN Fl lC XI, CL4 t TR21, TR31

'---y--/

[Z104l CZS-OH7B>

TR31

'---y--/

CZ297l CZS-OH9A-1 >

TR51 MA (J)

TR, TR21, TRS 1, CL (0)

CL 21, CL 31, R I, G 1, WO N

FOR SCHEME BF1142 ONLY

.......,~-- Xl,TR41,CL31 CL 41, CL2, R 1, G 1 XI, TR41, TR, TR21 TR 31, CL 21, CL, CL 2 X1,XA,XB,TR,TR21

..-"-t Cl,CL21,Rl, Gt, WO co

___...._CL4J,RI,Gt, WO TR31 TR51 MA

<G>

(f)

<El CL,CL2,Cl3 CL4t,TR2t,TR2 TR31,TR4J TR4t.Xt

[__PREFABRICATED CABLES~

Xt, CL41 TR21, TR31 m>

FOR SCHEME BEll12 ONLY N

(J)

TR, TR21, TR51, CL CL21,CL31,R1,G1,WO

'---y--/

CZ299J

<ZS-DH9A-2>

c

'---y--/

CZ298l CZS-OH9B.. 1 >

TRJ,TRtl,CLt.CLll R,G,WOl

<I)

CD

'---y--/

CZ300l

<ZS-DH98*2)

X1,TR41 SP,SP X t, CL, CL 3, CL 4, Cl 2, CL 4 t,

TR,CL31,TR41,TR3t,TR2

--~~~---------/\\ _______________ ___

/

ZS-DH9A ZS-DH9B

-~--

M E

OC E

Xl,G1,Rl,WO

<E>

N 15 Xt,TR3t,TR5t,CL2, CL41,Rl,Gt TR4t,TR51 CL,CL2 __

(J)

MA M

E TR, TR21, TR31,CL CL21,CL31,RI,Gt, WO ac CS PUMP 1 OUT VLV. HV1530 SCHEME BE1156 SHEET 2JA 15 NOT£ I:

1 (IF HV-OH9A rnv-oHq;s)

IS OPEN, VALVE HV-1531

<HV-1530> IS THROTTLED

<:ooWN. IF HV-DH9A <HV-DH98)

IS CLOSE, HV-t.531 CHV-1530> OPENS FULLY ON SA SIGNAL.

LEGEND

~ -INLINE CABLE SPLICE PER Et037A SECT. 4 & 5.

PREFABRICATE CABLE~

FOR SCHEMES Bflt48, BEt157 ZS-DH7A CZS-DH7B>

~

13 JM oc !M

'-y-/

BLOCK MANUAL OPEN HV-OH9A

<HV-DH9B>

ZS-DH9A

<ZS-OH9B>

~

IOIM QC !M

'---y--/

BLOCK OPEN HV-OH7A CHV-DH7Bl ZS-OH9A t ZS-OH9BJ 16f ~~ 1 M

M

'---y--/

CLOSE HV*OH7A

<HV-DH7B>

THIS DRAWING WAS REDRAWN ON CAD & SUPERCEDES REV.9 SCALE NONE DESIONED ORA~ JOR DATE 02-05-91 DAVIS-BESSE NUCLEAR POWER STATION r.~!!~I E0~2 *--Ly a

ELEMENTARY WIRING DIAGRAMS REACTOR COOLING SYSTEM CTMT EMER SUMP & BWST OUTLET VALVE ORAWlNG NO.

-e E52B SHo 19C DB 08-26-05 DFN=F :/SCHEME/E52BS 19C. DGN REV.

13