SCHEME NO.
Q.
- )
V>
Bf 1277 z
~
l..LJ
_J LL.
~;;
'Z~
z:
wen 0
,J.
(/)
~
.....I
-.a
<(
\\j -
~
z -
- ic :c u
CD II)
~
II> >
~
£0 7489 s.u.
WIRE PREFIX EQUIPMENT SA OUTPUT RELAY MCC NO. CHANNEL AT MAIN c.s.
DESCRIPTION CTRL. BO c
CD B
E M
N F
SAt SA2 SA3 SA4 KA KB Bf'1277 F12C 011 2
CXB HISl395 C5717 COF12C 8Ft277 £V13950 MVl3950 NV13950 FPSLJ377A C57550 C5756C K27F K27f SW. ISO. VLV. TO CLNG. WTR. 1395 7¥.13 be
- 1.
OPEN MCC Fl2C 480V, 3.,, 60HZ ffi 69 A
xr
<SEE NOTE 7) 17
~
B 8
rlCD SAl SA4 XI C
26j_
r-f(~ XI 7S..-.SM 27 68 520 2 OSBBJ_ tLKB B~ J_ LL KA
)- -~--)s2 -
CD
~"TR417~ill 7
XB XA SA2 SA4 TR41 t!
13? § 2A5 TR4t
?g TR4t 480/120V D <SEE anY. NOT£ 11 )
---<.JM TR31
?~
TR31 H
CLOSE STOP
<SEE NOTE 9>
uN L
TR2H CLOSE CL21 OP\\;--~----;f~ fH ~[
c~~i-tf; Y-TR21
'(
PSLNOTE 6) CL21 TR t
~
CL 5
OS 12 E
F co~CL21 B.
E CD Cl:
3 OS t 0 m1~
ro i
C Clt1 1~
3l~
~
7?fosr TR1-Cl Cll-
~
61~
4i~
~CD rro TR CL-Tl Tl T2
, T3 Tl TR 9 ft 16 Jl 22.e t8
- I*
INDICATION Olll.1 B
I B
.1 Xl,XA,XB, TR, TR21 CL,CL21,R1,G1,WO Xt,TR41,
~ 6 l3 CL,CL2 TR4T,CL,CL2, 2? 00 Toe <PREFABRICATED CABLE>
<E> CL21,Rl,G1, Xt,TR41.CL,CL2,CL3 WO M
M SA2 SA4 R 1 G 1
<ROUTED UNDER SEPERATE M
M CZ996l tZS1395>
.1 l
SCHEME NO. SEE OWG. E-761 >
r.
Rllg_ ifG 1~
BLOCK DIAGRAM Rt Gt NOTES 3
2 B
- l. DELETED N.
- 2. FOR GENERAL NOTES SEE DWG. E-488 INDEX SH.
Rt
' R / ' G /
Gt
- 3. FOR LOCAL PUSHBUTTONS ANO IND. LIGHTS DETAILS SEE OWG. E-308, SH.7, TYPES 3,4 AND 6.
C.D /
CD
- 4. FOR CONTROL SWITCH <CS> DETAILS SEE DWG. E-308, t 4 SH.7, FIG.7.
OS
- 5. FOR VALVE LIMIT SW. DEV. SEE DWG. E-308, SH.8H, FIG. P.
WO CD
CL2 __ R....___.__,1
- 1. FOR VENDOR OWG. REFER TO E-178. SEE VENDOR DWG.
FOR SFAS INTERNAL WIRING.
- 8. DELETED.
- 9. OVERLOAD HEATERS REPLACED BY SHORTING BARS.
- 10. ADD LOCAL CONTROL SWITCH GUARD ASSEMBLY PER E-302A SH. 185A & 8 TO SWITCH NV13950 & NVl3990.
IJ. FIELD TO ADJUST ROTOR 14 WITH SWltCH CONTACTS 13 THAU 16 TO ACTUATE WHEN VALVE REACHES 20X OPEN +5%,
-01..
'd BA
~
/ '
- DATA/
C BYPASS LIGHT wot KA
Di-SWITCH T
10 OS CL3
<SEE NOTE 7>
s.A.z ~
CD
'Er DATA/
M21' CL GIR
/ '
~
..... ~
BYPASS LIGHT WO BYPASS SWITCH
THIS DRAWING WAS REDRAWN ON CAOO AND SUPERSEDES REVISION 12 SCALE NONE DESIGNED DRAWN EAL DATE 04-21 -04 DAVIS-BESSE NUCLEAR POWER STATION UNIT NO. I THE TOLEDO EDISON COloFANY ELEMENTARY WIRING DIAGRAM LAKE WATER SYSTEM SW. ISO. VLV TO CLNG. WTR. 1395 DRAWING NO.
REV.
1~
23b
!1 CL
...i, SA4 tz._I -'X'SM 4
~
E-48B SH.9A 14 DB 08-19-05 DFN= F:/SCHEME/E48BS9A.DGN
-~* ---~------*----~~-
.. *--*-**-*... ~,.. -- "" '"'.
- -~-*