ML17039A752

From kanterella
Jump to navigation Jump to search
1 to Updated Final Safety Analysis Report, Drawing E-0030B, Rev 2, Sheet 0016B
ML17039A752
Person / Time
Site: Davis Besse 
Issue date: 11/21/2016
From:
FirstEnergy Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17039A594 List: ... further results
References
L-16-322 E-0030B, Rev 2
Download: ML17039A752 (1)


Text

(Page 2 of 2)

NEWFAX 3/85 N58313 r

0 0

I

'q"'

r-0 I

LO C> 0 0

en I

c:::

iS

~ u

ii r-l.J.J c:> a::

~

I l.J.J L{')

0 0..

LO 0::::

f'I'")

0 LLJ 0

<

(...)

c:::a Q

0 u.J

.. =>

(..) <...)

V>

z :z V>

~ 0 C>

~

  • I

~

I"°)

oC N - -

c I

I r-

<X>

N -

0

~

....-.-~-...... 1**--*---..

125VOC

{- -

FOR CLOSE ~ MTR.

125VOC

{- -

FOR TRIP REKITE Cl.OSURE {: :

AUX.

CONT.

REMOTE lRIP {: :

WIRING DIAGRAM

-iA OJSC ~

"-~I

-1.!!

-0 0--2C

~ISC I I 24 I 23 I

I I 21 I 22 I

I SEE NOTE 3

"-u L4 L7 l

w CELL HOUSING SWITCHES SffOWN IN

<BREAKER IN POS.)

JTI 4! I 3}L 1 I

µ I

I 1J 58 I aJ..

  1. b I

TNOT£ t I

~IT L ____ J

~

ff RE0 1ll~

- -12:c-----_-_-_

~--11c-----

STATIC TRIP SENSOR 9C~

1oc-i_eA 11c.....'.b N

9 SY EO 7489 SCHEME i

~~REMOTE TRIP IF 9

REO'O.

-~----------------------

4 l A

AAA.AAAAAA 58 78 9C ltC 13 IS 17 19 21 23 2 J (l

13

~

15..l. l7

~

19 £. 21 A 23 A.

14

~ 16 EC 18

""20

.., 22 EC 24 I()

11

~11c~

12 ~

~

I I

IX

~

I I

2Y.,._ __

.. 2X I,.. - ~ 2T I

~,

I u,e 68 JOC 12c 18 2

2 24 I

<->--8 c! _______ Y ----I -=-=-: __ v __ ~_:__: _ _:_j H--u:n~-------------'+

ABB BREAKER SCHEME SHOWN IN TRIP POSITION & WITH CLOSING MECHANISM SPRING DISCHARGED ABB WIRING DIAGRAM, FRONT VIEW LEGEND:

BA BELL ALARM OPERATES ON F All T OR OVERCURRENT, NANUAl RESET TC TRIP COIL UV th1ERVOLTAGE RELAY X

CLOSING RELEASE COIL Y

ANTI PtW RELAY M

SPRING CHARGING MOTOR MC/aa N.O. MOTOR CUTOFF SWITCH MC/bb N.C. MOTOR CUTOFF SWITCll G

N.O. AUX. SW. CONTACT b

N.C. AUX, SW. CONTACT P8 a.OSE PUSH8UTTON ON 8kR FACEPlATE DISC MOTOR DISCONNECT SWITCH NOTES:

I. TWO SPARE AUX COOTACTS ARE NOT WIRED.

2. INFORMATION PROVIDED IN THIS DRAWING IS BASED 00 VENDOR DRAWING 774H-21-9-3.

l SWITCH L3/l4 IN 8C£5

  • ---*--*~---**--.. -**-******-*--******.. -*-.

SCALE NONE DESIGNED DRAWN JOR DATE 07-1 Q.. Q3 DAVIS-BESSE NUCLEAR POWER STATION UNIT NO. 1 LIGHTING PANEL BREAKERS BCE5, BDF5 ~ BF517 SCHEME ~ INTERNAL WIRING DIAGRAM DRAWING NO.

E -3 OB SH

  • 168 REV.

2 DB 10-20-06 DFN=F:/SCHEMEIE30BS16B.DGN

... ~--................ _,. ____ ~ ____ _,,