Surface Water Resources (SW) RAI SW-6 WF3 LPDES DMR Data Summary
ML17037D321
Person / Time
Site: Waterford 
Issue date: 02/07/2017
From:
Entergy Operations
To: Keegan E
Division of License Renewal
ELAINE KEEGAN, NRR/DLR, 415-8517
Shared Package
ML17018A143 List:
References
Download: ML17037D321 (17)


Text

WF3 Outfall 001 (Once-Through Non-Contact Cooling Water)

Month/

Year Temperature (qF)

Thermal Discharge (MBTU/hr)

Flow (mgd)

Total Chlorine (lbs/day)

Monthly Average Daily Maximum Daily Maximum Monthly Average Daily Maximum Daily Maximum LPDES Limit Report 118 9,500 Report Report 211 Jan-14 65.8 69.1 8,850 1,011 1,172 (a)

Feb-14 71.1 80.0 8,800 866 1,145 (a)

Mar-14 71.6 84.0 8,860 1,106 1,269 (a)

Apr-14 70.6 90.2 8,930 992 1,291 (a)

May-14 79.7 96.8 8,813 974 1,373 (a)

Jun-14 101.1 106.8 8,930 1,098 1,305 (a)

Jul-14 103.9 109.7 8,982 1,217 1,272 (a)

Aug-14 105.7 107.8 8,869 1,149 1,189 (a)

Sep-14 104.0 111.0 8,900 1,229 1,479 (a)

Oct-14 92.7 100.2 8,963 1,276 1,462 (a)

Nov-14 81.7 88.5 8,995 1,097 1,319 (a)

Dec-14 74.9 83.5 8,900 984 1,158 (a)

Jan-15 69.7 78.9 8,815 1,022 1,342 (a)

Feb-15 73.0 85.5 8,940 936 1,250 (a)

Mar-15 68.9 83.6 8,740 1,026 1,230 (a)

Apr-15 88.4 93.6 8,850 911 1,110 (a)

May-15 98.1 107.5 8,850 911 1,160 (a)

Jun-15 96.0 105.0 8,900 1,026 1,470 (a)

Jul-15 103.8 109.0 8,920 1,243 1,298 (a)

Aug-15 105.9 110.0 8,910 1,210 1,275 (a)

Sep-15 106.0 110.0 8,910 1,066 1,298 (a)

Oct-15 86.0 108.0 8,820 1,108 1,143 (a)

Nov-15 65.0 69.0 0

0.383 0.750 (a)

Dec-15 74.8 80.8 8,746 1,072 1,303 (a)

Jan-16 75.7 84.7 8,770 921 1,150 (a)

Feb-16 74.7 81.3 8,735 878 1,127 (a)

Mar-16 82.3 91.4 8,730 892 1,190 (a)

Apr-16 87.5 92.5 8,850 1,000 1,209 (a)

May-16 94.3 98.3 8,770 1,057 1,330 (a)

Jun-16 101.2 106.6 8,900 1,149 1,292 (a) a.

No chlorination or biocide usage occurred during this reporting period.

WF3 Outfall 001 (Once-Through Non-Contact Cooling Water) (b)

Month/

Year NOEC, Pass/Fail [0/1] Lethality, 48-Hour Acute, Pimephales promelas NOEC, Value [%], Lethality, 48-Hour Acute, Pimephales promelas NOEC, Value [%], Coefficient of Variation, 48-Hour Acute, Pimephales promelas Monthly Average Minimum 48-Hour Minimum Monthly Average Minimum 48-Hour Minimum Monthly Average Minimum 48-Hour Minimum LPDES Limit Report Report Report Report Report Report Mar-14 0

0 42.0 42.0 0

0 Jun-14 0

0 42.0 42.0 0

0 Sep-14 0

0 42.0 42.0 6.6 6.6 Dec-14 0

0 42.0 42.0 0

0 Mar-15 0

0 42.0 42.0 0

0 Jun-15 0

0 42.0 42.0 6.63 6.63 Sep-15 0

0 42.0 42.0 5.3 5.3 Dec-15 0

0 42.0 42.0 10.1 10.1 Mar-16 0

0 42.0 42.0 5.3 5.3 Jun-16 0

0 42.0 42.0 0

0

b.

All results reported Passed.

WF3 Outfall 001 (Once-Through Non-Contact Cooling Water) (b)

Month/

Year NOEC, Pass/Fail [0/1] Lethality, 48-Hour Acute, Daphnia pulex NOEC, Value [%], Lethality, 48-Hour Acute, Daphnia pulex NOEC, Value [%], Coefficient of Variation, 48-Hour Acute, Daphnia pulex Monthly Average Minimum 48-Hour Minimum Monthly Average Minimum 48-Hour Minimum Monthly Average Minimum 48-Hour Minimum LPDES Limit Report Report Report Report Report Report Mar-14 0

0 42.0 42.0 10.1 10.1 Jun-14 0

0 42.0 42.0 5.28 5.28 Sep-14 0

0 42.0 42.0 10.1 10.1 Dec-14 0

0 42.0 42.0 5.3 5.3 Mar-15 0

0 42.0 42.0 0

0 Jun-15 0

0 42.0 42.0 0

0 Sep-15 0

0 42.0 42.0 0

0 Dec-15 0

0 42.0 42.0 5.3 5.3 Mar-16 0

0 42.0 42.0 5.3 5.3 Jun-16 0

0 42.0 42.0 5.3 5.3

b.

All results reported Passed.

WF3 Outfall 101 (Liquid Waste Management)

Month/

Year pH (s.u.)

TSS (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 20 Report Jan-14 6.15 6.40 0

0 0.0129 Feb-14 6.09 6.18 0

0 0.0129 Mar-14 6.02 6.25 0

0 0.0124 Apr-14 6.09 6.56 0

0 0.0133 May-14 6.03 6.91 0

0 0.013 Jun-14 6.08 6.72 0

0 0.0124 Jul-14 6.08 6.72 0

0 0.0134 Aug-14 6.02 6.17 0

0 0.0130 Sep-14 6.06 6.14 0

0 0.0126 Oct-14 6.06 6.52 0

0 0.0128 Nov-14 6.02 6.74 0

0 0.0116 Dec-14 6.04 6.21 0

0 0.0130 Jan-15 6.09 6.64 0

0 0.013 Feb-15 6.10 6.10 0

0 0.0126 Mar-15 6.04 6.22 0

0 0.0126 Apr-15 6.10 6.50 0

0 0.0133 May-15 6.06 6.43 0

0 0.0122 Jun-15 6.07 6.33 0

0 0.0128 Jul-15 (c)

(c)

(c)

(c)

(c)

Aug-15 6.08 7.07 0

0 0.0126 Sep-15 6.04 6.36 0

0 0.0131 Oct-15 6.01 6.25 0

0 0.0130 Nov-15 6.17 6.17 0

0 0.0134 Dec-15 6.04 6.21 0

0 0.013 Jan-16 (c)

(c)

(c)

(c)

(c)

Feb-16 6.01 6.14 0

0 0.012 Mar-16 6.02 6.17 0

0 0.013 Apr-16 6.06 6.12 0

0 0.013 May-16 6.03 6.24 0

0 0.013 Jun-16 6.05 6.17 0

0 0.013 c.

No discharges occurred.

WF3 Outfall 201 (Boron Management System) (d)

Month/

Year pH (s.u.)

TSS (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 20 Report Feb-14 6.03 6.11 0

0 0.0122 Mar-14 6.02 6.08 0

0 0.0126 Apr-14 6.04 6.43 0

0 0.0129 May-14 6.19 6.87 0

0 0.0125 Jul-14 6.09 6.61 0

0 0.0129 Aug-14 6.08 6.97 0

0 0.0126 Oct-14 6.04 6.12 0

0 0.0127 Mar-14 6.14 6.14 0

0 0.0118 May-15 6.02 6.38 0

0 0.0122 Jun-15 6.11 6.27 0

0 0.0121 Jul-15 6.21 6.50 0

0 0.0122 Aug-15 6.10 6.20 0

0 0.0124 Sep-15 6.07 6.23 0

0 0.0123 Oct-15 6.03 6.28 0

0 0.01285 Dec-15 6.03 6.07 0

0 0.013 Feb-16 6.04 6.12 0

0 0.013

d.

Includes only months where there was a discharge.

WF3 Outfall 301 (Filter Flush Water)

Month/Year Flow (mgd)

Daily Maximum LPDES Limit Report 2014 (c) 2015 (c) 2016 (e) c.

No discharges occurred.

e.

No discharges through June 2016.

WF3 Outfall 401 (Steam Generator Blowdown) (d)

Month/

Year pH (s.u.)

TSS (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 20 Report Apr-14 6.96 8.23 0

0 0.05113 May-14 6.85 7.18 0

0 0.0388 2015 (c)

(c)

(c)

(c)

(c) 2016 (e)

(e)

(e)

(e)

(e)

c.

No discharges occurred.

d.

Includes only months where there was a discharge.

e.

No discharges through June 2016.

WF3 Outfall 501 (Auxiliary Cooling Water Basin A) (d)

Month/

Year pH (s.u.)

TSS (mg/l)

TOC (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 50 20 Report 2014 (c)

(c)

(c)

(c)

(c)

(c)

Nov-15 7.55 7.57 0

0.74 0

0.193 2016 (e)

(e)

(e)

(e)

(e)

(e)

c.

No discharges occurred.

d.

Includes only months where there was a discharge.

e.

No discharges through June 2016.

WF3 Outfall 601 (Auxiliary Cooling Water Basin B) (d)

Year pH (s.u.)

TSS (mg/l)

TOC (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 50 20 Report May-14 7.62 7.63 0

0 0

0.180 Nov-15 7.50 7.51 0

0.77 0

0.173 2016 (e)

(e)

(e)

(e)

(e)

(e)

d.

Includes only months where there was a discharge.

e.

No discharges through June 2016.

WF3 Outfall 701 (Dry Cooling Tower Sump #1)

Month/

Year PH (s.u.)

TSS (mg/l)

Total Zinc (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

FAC (mg/l)

TOC (mg/l)

Total Chromium (mg/l)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 1.0 20 Report 0.5 50 0.2 Jan-14 7.36 7.36 8.0 (c) 0 0.0836 (c)

Feb-14 7.41 7.42 0

(c) 0 0.1203 (c)

Mar-14 7.38 7.38 0

(c) 0 0.0180 (c) 5.8 Apr-14 7.09 7.11 0

(c) 0 0.0713 (c)

May-14 7.86 7.86 0

(c) 0 0.0446 (c)

Jun-14 7.43 7.45 0

(c) 0 0.1694 (c) 7.0 Jul-14 7.55 7.57 0

(c) 0 0.0982 (c)

Aug-14 7.70 7.71 0

(c) 0 0.0947 (c)

Sep-14 7.52 7.53 0

(c) 0 0.3779 (c) 5.2 Oct-14 7.56 7.57 0

(c) 0 0.0078 (c)

Nov-14 7.38 7.39 4.0 (c) 0 0.0034 (c)

Dec-14 7.23 7.24 0

(c) 0 0.0166 (c) 3.42 (c)

Jan-15 7.89 7.89 0

(c) 0 0.0098 (c)

Feb-15 7.74 7.74 5.2 (c) 0 0.0037 (c)

Mar-15 7.56 7.57 0

(c) 0 0.0058 (c) 4.36 Apr-15 7.87 7.88 0

(c) 0 0.0107 (c)

May-15 7.88 7.89 0

(c) 0 0.0188 (c)

Jun-15 7.46 7.47 4.4 (c) 0 0.0147 (c) 9.60 Jul-15 7.49 7.49 0

(c) 0 0.0046 (c)

Aug-15 7.45 7.46 0

(c) 0 0.0050 (c)

Sep-15 7.22 7.23 0

(c) 0 0.0125 (c) 1.40

WF3 Outfall 701 (Dry Cooling Tower Sump #1)

Month/

Year PH (s.u.)

TSS (mg/l)

Total Zinc (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

FAC (mg/l)

TOC (mg/l)

Total Chromium (mg/l)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 1.0 20 Report 0.5 50 0.2 Oct-15 7.17 7.18 0

(c) 6.26 0.0397 (c)

Nov-15 7.59 7.61 0

(c) 0 0.061 (c)

Dec-15 8.01 8.02 0

(c) 5.52 0.016 (c) 3.2(f)

(c)

Jan-16 7.57 7.59 0

(c) 0 0.007 (c)

Feb-16 7.36 7.36 4.1 (c) 0 0.008 (c)

Mar-16 7.41 7.43 0

(c) 5.97 0.015 (c) 4.50 Apr-16 7.27 7.32 4.2 (c) 5.34 0.019 (c)

May-16 7.13 7.14 0

(c) 0 0.014 (c)

Jun-16 6.75 7.12 0

(c) 0 0.017 (c) 11.70

c.

No discharges occurred.

f.

Sample result included in January 2016 Discharge Monitoring Reports.

WF3 Outfall 801 (Dry Cooling Tower Sump #2)

Month/

Year PH (s.u.)

TSS (mg/l)

Total Zinc (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

FAC (mg/l)

TOC (mg/l)

Total Chromium (mg/l)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 1.0 20 Report 0.5 50 0.2 Jan-14 7.31 7.31 5.3 (c) 0 0.0043 (c)

Feb-14 7.36 7.38 0

(c) 0 0.0093 (c)

Mar-14 7.02 7.02 0

(c) 0 0.0086 (c) 6.7 Apr-14 7.14 7.16 0

(c) 0 0.0062 (c)

May-14 7.56 7.56 8.3 (c) 0 0.031 (c)

Jun-14 7.32 7.33 0

(c) 0 0.008 (c) 8.1 Jul-14 7.41 7.42 0

(c) 0 0.022 (c)

Aug-14 7.62 7.63 0

(c) 0 0.008 (c)

Sep-14 7.64 7.65 0

(c) 0 0.005 (c) 4.0 Oct-14 7.34 7.35 0

(c) 0 0.006 (c)

Nov-14 7.41 7.42 6.0 (c) 0 0.022 (c)

Dec-14 7.56 7.57 0

(c) 0 0.0186 (c) 3.72 (c)

Jan-15 7.98 7.99 0

(c) 0 0.0162 (c)

Feb-15 7.65 7.66 4.3 (c) 0 0.0043 (c)

Mar-15 7.97 7.98 4.9 (c) 0 0.0103 (c) 2.96 Apr-15 7.65 7.65 0

(c) 5.37 0.0105 (c)

May-15 8.11 8.13 0

(c) 0 0.0165 (c)

Jun-15 7.64 7.65 0

(c) 5.3 0.0197 (c) 6.70 Jul-15 7.60 7.61 0

(c) 0 0.0047 (c)

Aug-15 7.49 7.50 4.2 (c) 5.26 0.0032 (c)

Sep-15 7.54 7.55 0

(c) 0 0.0109 (c) 1.40

WF3 Outfall 801 (Dry Cooling Tower Sump #2)

Month/

Year PH (s.u.)

TSS (mg/l)

Total Zinc (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

FAC (mg/l)

TOC (mg/l)

Total Chromium (mg/l)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 1.0 20 Report 0.5 50 0.2 Oct-15 7.96 7.98 13.3 (c) 0 0.0797 (c)

Nov-15 7.78 7.80 12.1 (c) 6.11 0.091 (c)

Dec-15 7.73 7.75 0

(c) 5.51 0.020 (c) 2.9(f)

(c)

Jan-16 7.41 7.42 7.1 (c) 0 0.009 (c)

Feb-16 7.52 7.52 0

(c) 0 0.009 (c)

Mar-16 7.67 7.67 0

(c) 5.3 0.021 (c) 3.10 Apr-16 7.58 7.59 0

(c) 6.0 0.019 (c)

May-16 6.90 7.07 4.2 (c) 5.92 0.015 (c)

Jun-16 7.08 7.10 0

(c) 0 0.023 (c) 1.40

c.

No discharges occurred.

f.

Sample result included in January 2016 Discharge Monitoring Reports.

WF3 Outfall 901 (Mobile Metal Cleaning Wastewater)

Year pH (s.u.)

TSS (mg/l)

Total Copper (mg/l)

Total Iron (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 1.0 1.0 20.0 Report 2014 (c)

(c)

(c)

(c)

(c)

(c)

(c) 2015 (c)

(c)

(c)

(c)

(c)

(c)

(c) 2016 (e)

(e)

(e)

(e)

(e)

(e)

(e) c.

No discharges occurred.

e.

No discharges through June 2016.

WF3 Outfall 1001 (Miscellaneous Intermittent Wastewater)

Month/

Year pH (s.u.)

TSS (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 20 Report Jan-14 7.23 8.85 10.0 8.2 0.025 Feb-14 7.99 8.15 11.3 7.0 0.0539 Mar-14 7.97 8.35 8.8 6.9 0.0431 Apr-14 8.11 8.12 7.0 7.8 0.0778 May-14 7.62 8.12 14.4 9.4 0.121 Jun-14 7.62 8.12 14.4 9.4 0.121 Jul-14 8.11 8.62 8.5 11.8 0.056 Aug-14 8.34 8.63 10.2 11.6 0.023 Sep-14 8.37 8.57 7.6 6.8 0.031 Oct-14 7.65 8.58 8.7 0

0.029 Nov-14 8.26 8.73 8.0 18.7 0.026 Dec-14 8.12 8.13 12.2 7.7 0.0462 Jan-15 7.84 8.61 9.2 9.5 0.0307 Feb-15 7.85 8.25 7.6 13.1 0.0195 Mar-15 7.87 8.18 0

7.78 0.0235 Apr-15 7.86 8.44 0

10.3 0.0408 May-15 7.69 8.43 0

8.9 0.0520 Jun-15 7.67 8.02 6.1 15.0 0.0565 Jul-15 7.88 8.00 4.7 8.6 0.0237 Aug-15 7.95 8.51 5.3 11.3 0.0171 Sep-15 7.97 8.22 5.9 8.21 0.0247 Oct-15 8.11 8.52 0

10.04 0.1198 Nov-15 7.70 8.06 0

9.07 0.043 Dec-15 7.40 9.00 6.30 10.19 0.066 Jan-16 7.57 8.65 0

9.66 0.022 Feb-16 7.89 8.76 14.9 13.09 0.030 Mar-16 7.77 8.37 10.5 12.6 0.036 Apr-16 7.97 8.56 6.4 11.62 0.045 May-16 7.84 8.02 5.2 7.89 0.037 Jun-16 7.22 8.39 5.5 7.04 0.016

WF3 Outfall 004 (Stormwater Runoff)

Month/

Year pH (s.u.)

TSS (mg/l)

TOC (mg/l)

Oil & Grease (mg/l)

Flow (mgd)

Instantaneous Minimum Instantaneous Maximum Daily Maximum Daily Maximum Daily Maximum Daily Maximum LPDES Limit 6.0 9.0 100 50 15 Report Mar-14 7.14 7.16 8.4 3.96 0

9.72 Jun-14 7.32 7.32 5.4 0

0 12.0 Sep-14 7.51 7.52 7.5 2.8 0

12.8 Dec-14 7.70 7.71 11.3 4.1 0

11.0 Mar-15 7.02 7.12 9.2 5.6 0

6.14 Jun-15 7.94 7.96 8.6 5.0 0

10.60 Sep-15 7.34 7.91 9.4 6.8 0

5.29 Dec-15 7.27 7.28 7.27 5.20 8.76 30.600 Mar-16 7.12 7.13 7.20 4.80 0

6.8 Jun-16 7.88 7.90 9.60 6.50 0

9.76

WF3 Outfall 005 (Energy Education Sewage Plant)

Month/

Year BOD-5 Day (mg/l)

PH (s.u.)

TSS (mg/l)

Flow (mgd)

Fecal Coliform (colonies/100 ml)

Monthly Average Daily Maximum Instantaneous Minimum Instantaneous Maximum Monthly Average Daily Maximum Daily Maximum Monthly Average Daily Maximum LPDES Limit 30 45 6.0 9.0 30 45 Report 200 400 Jun-14 0

0 7.91 7.91 6.0 6.0 0.05 0

0 Dec-14 0

0 7.61 7.65 0

0 0.0458 0

0 Jun-15 4.5 5.8 7.57 7.60 2

4 0.057 0

0 Dec-15 0

0 7.67 7.68 0

0 0.0541 0

0 Jun-16 0

0 7.28 7.34 13.0 13.0 0.041 0

0