Waterford Steam Electric Station, Unit 3 Applicants Environmental Report Operating License Renewal Stage 3-36

Table 3.2-3 Annual Air Emissions Inventory Summary, 2010-2014 Year Annual Emissions (tons/year)(a)

SOx NOx CO PM10 VOCs HAPs 2010 0.4 15.0 3.9 0.7 1.0 0.01 2011 0.5 20.5 5.3 1.0 1.2 0.02 2012 1.8 38.5 9.1 2.2 2.7 0.04 2013 0.6 18.1 4.7 0.8 1.0 0.03 2014 0.6 22.2 5.5 1.2 1.5 0.02 (Entergy 2015i)

a. Emissions are based on calculated gallons of fuel usage shown below.

Equipment 2010 2011 2012 2013 2014 Stationary diesels (> 600 hp) 52,986 68,648 61,562 62,139 56,477 Stationary diesels ( 600 hp) 2,605 2,605 3,185 2,624 7,270 Portable diesels ( 600 hp) 7,468 11,974 74,529 4,500 20,902 Portable boiler (< 100 MMBtu) 0 64,467 65,280 200,980 200,940 79,815 Portable gasoline 110 110 0

0 0

Waterford Steam Electric Station, Unit 3 Applicants Environmental Report Operating License Renewal Stage 3-37

Table 3.2-4 Annual Greenhouse Gas Emissions Inventory Summary, 2010-2014 Carbon Dioxide Equivalent (CO2e) Emissions, Metric Tons(a)

Emission Source 2010 2011 2012 2013 2014 Combustion sources (Table 3.2-2) 647 1,513 2,094 2,767 2,766 1,684 Workforce commuting 2,722 2,722 2,722 2,722 2,722 Total 3,369 4,235 4,816 5,489 5,488 4,406 (Entergy 2015i)

a. GHG calculated emissions are based on the following:

Fuel usage for combustion sources shown in footnote a to Table 3.2-3.

Workforce commuting:

1. Statistical information from U.S. Census Bureau indicates that 10.5 percent of U.S. residents carpool to work (USCB 2015). Number of WF3 employees as of January 2016 was 641.

Utilizing the 10.5 percent USCB carpool statistic, a value of "574 passenger vehicles per day was utilized.

2. The EPA's Greenhouse Gas Equivalencies Calculator shows that the CO2e/vehicle/year was estimated to be 4.75 metric tons (EPA 2015b).
3. Carbon dioxide has a global warming potential (100-year time horizon) of 1 based on Table A-1 to Subpart A of 40 CFR Part 98.
4. 573 vehicles x 4.75 metric tons CO2e/vehicle/year x 1 (global warming potential).