ML17037C658

From kanterella
Jump to navigation Jump to search
Figure 5.3-2; Stand-by Gas Treatment System
ML17037C658
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 02/06/2017
From:
Niagara Mohawk Power Corp
To:
Office of Nuclear Reactor Regulation
References
Download: ML17037C658 (1)


Text

DEMISTER BOUNDARY REACTOR BUILDING SELF OPERATING VAC RELIEF VALVE AIR FOR DECAY HEAT COOLING ELECTRIC AIR HEATER PRE F ILTE R ACTIVATED CHARCOAL ADSORBER HI G H EFF I C I E NCY PA RT I C U L AT E AFTER FILTER TO REACTOR BUILDING EQUIP DRAIN SUMP FILTER TRAIN A FAN FLOW ELEMENT FROM REACTOR BUILDING M

RECIRCULATION MIXiNG PLENUM C

M C

FROM DRY WELL AND SUPPRESSION CHAMBER PURGE CONNECTION AIR FOR DECAY HEAT COOLING

~f DEMISTER C

C FAN C

TO STACK ELECTRIC AIR HEATER P R E F I LT E R AC T I V AT ED CHARCOAL ADSORBER HIGH E F F I DIE N C Y PARTICULATE AFTER FILTER TO REACTOR BUILDING EQUIP DRAIN SUMP FILTER TRAIN 5 FIG. 5.3-2 STAND-BY GAS TREATMENT SYSTEM NINE MI L E POINT NUCLEAR STATION UNIT 2 NIAGARA MOHAWK POWER CORPORATION PRELIMINARY SAFETY ANALYSIS REPORT