JAN 29 1974 Docket Ho. 50-220 Niagara Hohawk Power Corporation ATTH:
Hr. Philip D. Raymond Vice President - Engineering 300 Erie Boulevard liest
- Syracuse, Hew York 13202 Gentlemen!
Ue are reviewing the information which you submitted on June 29, 1973, concerning the high energy line breaks outside the contaiammt for the Hine KUu Point Unit 1.
VTe find that our review cannot be. completed without the fo1lowing additional information:
1.
Define the minimum design pressure of the main steam tunnel and(or its component walls or slabs.
2.
Describe the anchors at the main steam line isolation valves and/or the seismic restraints designed as pipe whipping restraints, 3.
Describe the reactor cleanup system pipeline run as related in proximity to the torus.
Provide necessary plan and elevation drawings shmdng its routing.
Indicate whether a rupture of this pipeline could cause damage to the torus.
You are requested to provide this information in one signed original and thirty-nine copies by kfarch 1, 1974.
Please contact us if you have any questions regarding the information requested.
Sincerely, Qria-
@anni Dennis L. Ziemann, Chief Operating Reactors Branch 82 Directorate of Licensing cc:
See next page
Niagara Hohawk Power Corporation JAN 2 9 )g74 cc:
J. Bruce i~facDonald, Esquire Deputy Commissioner and Counsel Mew York State Department of Commerce and Counsel to the Atomic Energy Council 99 Mashington Avenue Albany, New Yorl'2210 Arvin E<<Upton, Esquire LeBoeuf, Lamb, Leiby 5 kfacRae 1757 N Street, H. if.
LlashingtonD.
C.
20036 Dr. Milldam Seymour Staff Coordinator.
New York State Atond.c Energy Council Ncw York State Department of Commerce 112 State Street Albany, Hew York 12207 Anthony Z. Roisman, Esquire Berlin, Roisman and Kesaler 1712 8 Street, N. H.
VasMngton, D. C.
20036 Oswego City Library Dis ibution cket File AEC PDR Local PDR RP Reading Branch Reading JRBuchanan, ORNL DJSkovholt, L:OR
- TJCarter, L:OR ACRS (16)
RO (3)
OGC DLZiemann, L:ORB //2 CJDeBEvec, L:ORB 82
- JCSnell, L:ORB (f2.
RMDiggs, L:ORB 82
- SVarga, L:RP OPPI C C~
'7403 SVhHAMCW L:ORB f/2~0 CJDeBevPc: sjh 1/28/74 ORB~
1/28/74 II2 DLZ emann 1/P/74 Eorm AEC.318 (Rev. 9 f3) AECM 0240 OpO Cl5 1 ~
d14eO l,520 264