6P,S IISGI P0

~

Op t

~~

i o

!4 "4 4:,

ip

+0

++**+

UNITED STATES t

NUCLEAR REGULATORY COMMISSION REGION I 631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA 19406

~<<20 ee Niagara Mohawk Power Corporation ATTN:

Mr. R.

R. Schneider Vice President Electric Operations

.300 Erie Boulevard West

Syracuse, New York 13202 Gentlemen:

Subject:

Iodine Pathway Study The Nuclear Regulatory Commission's. Office of Inspection and Enforcement is currently working on a study to determine the feasibility of using routine licensee monitoring data to evaluate the predictive models for the environmental transport of radioiodine (specifically I-131) through the air-grass-cow-milk chain.

We are considering cases where elevated concentrations of radioiodine have appeared in milk samples.

A search of licensee environmental monitoring reports has identified thirty-eight such cases.

Enclosure 1 lists those cases of interest for your Nine Mile Point facility.

We believe that such a perspective study will be valuable in gaining a better grasp of the accuracy of the current model and will assist in understanding some of the mechanisms which affect the movement of iodine through the chain.

In order to accomplish these objectives we will need the detailed effluent

release, meteorological, and dairy (goat) farm data which are specified in Enclosure 2.

We request your. cooperation in providing this information.

Please send the requested information to this office within thirty (30) days.

If there are any questions or additional information needed, please contact J. Philip Stohr of this office.

Sincerely, Boy e 8. Grier Director

Enclosures:

As Stated

0 tJiagara Mohawk Pow r Corporation cc w/encl:

T. E. Lempges,'eneral Superintendent, Nuclear Generation T. J. Perkins, Station Superintendent C. L. Stuart, Operations Supervisor E. B. Thomas, Jr., Esquire A. Z. Roisman, Counsel for Citizens Ceanittee for Protection of the Environment bcc w/encl:

IE Mail 4 files (For Appropriate Distribution)

Central Files Public Document Room (PDR)

Local. Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

Technical Information Center (TIC)

REG:I.Reading Room State of Hew York A. Z. Roisman, Counsel for Citizens Cormittee for Protection of the Environment t

DATE OF SAMPLE 7/22/75 7/22/75 7/22/75 9/22/75 9/22/75 9/22/75 ENCLOSURE 1

FACILITY NINE MILE POINT I131 CONTENT IN MILK Ci 1

0.7& +.38 1.08 +.19 2.61

+.29 1.70 +.14 0.04 +.11 2.99 +.20 LOCATION 83

0

ENCLOSURE 2

INFORMATION RE UIRED FOR IODINE PATHWAY SURVEY For the cases listed in Enclosure 1, the following detailed (day-by-day/

hour-by-hour) information is needed.

For items 1

and 2', it would be helpful to have the data for a period of two weeks prior to the elevated milk results and for one week after.

1)

Gaseous I-131 Effluent Releases a)

Height(s) of release.

b)

Minimal cross sectional area of surrounding buildings if release is not from a free-standing stack.

c)

Heat emission rate of release.

d)

Duration of release.

e)

Exit velocity of release at vent and stack.

f Inside diameter of stack vent where release occurred.

g)

Any documented, short-term, peaked releases during period of interest.

h) If release is given as an average value, the maximum and minimum values for the period of interest are needed.

2)

Meteorology a)

Wind speed (at height(s) of release, preferably).

b)

Wind direction (at height(s) of release, preferably).

c)

Atmospheric Lapse Rate (at):

d), Dew Point.

e Precipitation (hourly, if possible).

3)

Dairy (Goat)

Farm Particulars a)

Pasturing methods.

b)

Unique or outstanding characteristics of the local terrain.

c)

Any other available and pertinent information.