Request for Additional Information Regarding Relief Request Numbers PR6 and PR7
ML17031A036
Person / Time
Site: Beaver Valley
(DPR-066, DPR-073)
Issue date: 02/03/2017
From: Taylor Lamb
Plant Licensing Branch 1
To: Richey M
FirstEnergy Nuclear Operating Co
Lamb TA, NRR/DORL/LPL1, 415-7128
References
CAC MF8340, CAC MF8341, CAC MF8342, CAC MF8343
Download: ML17031A036 (3)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 February 3, 2017 Mr. Marty L. Richey, Site Vice President FirstEnergy Nuclear Operating Company Beaver Valley Power Station Mail Stop A-BV-SEB1 P.O. Box 4, Route 168 Shippingport, PA 15077

SUBJECT:

BEAVER VALLEY POWER STATION, UNIT NOS. 1AND2-REQUEST FOR ADDITIONAL INFORMATION REGARDING RELIEF REQUEST NUMBERS PR6 AND PR? (CAC NOS. MF8340, MF8341, MF8342, AND MF8343)

Dear Mr. Richey:

By letter dated August 31, 2016 (Agencywide Documents Access and Management System Accession No. ML16245A320), FirstEnergy Nuclear Operating Company submitted 28 proposed alternatives and relief requests for the Beaver Valley Power Station, Unit Nos. 1 and 2 (BVPS-1 and BVPS-2). The relief requests are associated with the fifth and fourth 10-year intervals of inservice testing program for pumps and valves for BVPS-1 and BVPS-2, respectively. As a part of the submittal, the U.S. Nuclear Regulatory Commission (NRC) staff noted the licensee requests that the BVPS-2 fourth 10-year interval coincide with the BVPS-1 fifth 10-year interval. The NRC staff requests a response to the enclosed questions to complete its review regarding Relief Request Numbers PR6 and PR?.

The draft questions were sent to Mr. Phil Lashley of your staff to ensure that the questions were understandable, the regulatory basis for the questions was clear, and to determine if the information was previously docketed. Please respond to the enclosed questions within 30 days of the date of this letter.

If you have any questions regarding this matter, please contact me at 301-415-7128 or Taylor.Lamb@nrc.gov.

Docket Nos. 50-334 and 50-412

Enclosure:

Request for Additional Information cc w/encl: Distribution via Listserv Si~

Taylor A~ect Manager Plant Licensing Branch I Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

REQUEST FOR ADDITIONAL INFORMATION RELIEF REQUEST NUMBERS PR6 AND PR?

FOR THE FOURTH AND FIFTH 10-YEAR INSERVICE TESTING INTERVALS FIRSTENERGY NUCLEAR OPERATING COMPANY BEAVER VALLEY POWER STATION. UNIT NOS. 1 AND 2 DOCKET NOS. 50-334 AND 50-412 By letter dated August 31, 2016 (Agencywide Documents Access and Management System Accession No. ML16245A320), FirstEnergy Nuclear Operating Company submitted 28 proposed alternatives and relief requests for the Beaver Valley Power Station, Unit Nos. 1 and 2 (BVPS-1 and BVPS-2). The relief requests are associated with the fifth and fourth 10-year intervals of inservice testing program for pumps and valves for BVPS-1 and BVPS-2, respectively. As a part of the licensee's submittal, the staff notes that they requested that the BVPS-2 fourth 10-year interval coincide with BVPS-1 fifth 10-year interval.

The NRC staff has reviewed and evaluated the information provided by the licensee and has determined that the following information is needed in order to complete its review of the relief requests.

Request for Additional Information PRS-1:

In Section 3, "Applicable Code Requirement," of the submittal, Table ISTB-3000-1, "lnservice Test Parameters," identifies flow rate as a test parameter, and Note 1 of the table states, in part, that, "... differential pressure or flow rate shall be measured or determined." Note 1 in Table ISTB-3000-1 is applicable to Group B tests. The boric acid transfer pumps are Group A pumps. Explain why Note 1 is referenced in Section 3, if it is not applicable to Group A pumps.

Request for Additional Information PRS-2:

Section 6, "Proposed Alternative and Basis for Use," of the submittal states, "separate vibration reference and acceptance criteria values will be used for the different test conditions of the recirculation and full flow tests." Please provide the vibration reference and acceptance criteria values.

Request for Additional Information PR7-1:

In Section 1, "ASME Code Components Affected," of the submittal, the residual heat removal pumps are listed as ASME Class 2 pumps. In Alternative Request Number PR8, the residual heat removal pumps are listed as ASME Class 3 pumps. Please state which classification is correct.

Enclosure

SUBJECT:

BEAVER VALLEY POWER STATION, UNIT NOS. 1AND2-REQUEST FOR ADDITIONAL INFORMATION REGARDING RELIEF REQUEST NUMBERS PR6 AND PR7 (CAC NOS. MF8340, MF8341, MF8342, AND MF8343)

DISTRIBUTION:

Public LPL 1 R/F RidsRgn1 MailCenter Resource RidsACRS_MailCTR Resource RidsNrrDorlLpl1 Resource RidsNrrPMBeaverValley Resource RidsNrrLALRonewicz Resource RidsNrrDeEpnb Resource RWolfgang, NRR ADAMS A ccess1on N b

ML17031A036 um er:

OFFICE DORL/LPL 1 /PM DORL/LPL 1 /LA NAME TLamb LRonewicz DATE 2/02/2017 2/02/2017 DE/EPNB/BC*

DAiiey 1/25/2017 OFFICIAL RECORD COPY

  • b
  • 1 d t d 1y e-ma1 ae DORL/LPL 1 /BC DORL/LPL 1 /PM SKoenick TLamb 2/02/2017 2/03/2017