ML16343B042

From kanterella
Jump to navigation Jump to search
Donald C. Cook Nuclear Plant, Units 1 & 2, Revision 27 to Updated Final Safety Analysis Report, Chapter 14, Table 14.2.5-2, Time Sequence of Events, Page 1 of 1
ML16343B042
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343B042 (1)


Text

I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T T Revision: 23Table: 14.2.5-2 Page: 1 of 1 UNIT 2 TIME SEQUENCE OF EVENTS Accident Event Time (sec) Rupture of a Steamline

1. Inside Containment With Offsite Power available Steam line ruptures 0.0 Low steamline pressure setpoint reached 0.26 Feedwater Isolation (All loops) 8.26 Steamline Isolation (Loops 2, 3 and 4) 11.26 Pressurizer empties 13.8 SI flow starts 27.26 Criticality attained 25.2 Boron from SI reaches core 38.4 Peak heat flux attained 118.2 Core becomes subcritical 131.2 2. Inside Containment Without Offsite Power available Steam line ruptures 0.0 Low steamline pressure setpoint reached 0.26 Feedwater Isolation (All loops) 8.26 Steam Isolation 11.26 Pressurizer empties 15.4 Criticality attained 30.8 SI flow starts 37.26 Boron from SI reaches core 52.0 Peak heat flux attained 266.2 Core becomes subcritical

~300