IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17 Table:14.1.10B-1 Page:

1 of 1 UNIT 2 TTIIM MEE SSEEQQUUEENNCCEE OOFF EEVVEENNTTSS

((FFUULLLL VV--55 CCOORREE))

Accident Event Time (sec)

Feedwater System Malfunctions:

Excessive feedwater flow at full power to a single steam generator (Manual Rod Control)

One main feedwater control valve fails fully open 0.0 Hi-hi steam generator water level signal generated 30.2 Turbine trip occurs due to hi-hi steam generator water level 32.7 Minimum DNBR occurs 34.0 Reactor trip occurs due to turbine trip 34.7 Feedwater isolation achieved 41.2