IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
23 Table: 14.A.1-2 Page:
1 of 1 CORE ACTIVITIES FOR CONTROL ROOM RADIOLOGICAL CONSEQUENCE ANALYSES Group Nuclide Activity (Ci)
Group Nuclide Activity (Ci)
Xe-131m 1.241E+06 Ru-103 1.899E+08 Xe-133 2.168E+08 Ru-105 1.459E+08 Xe-133m 6.902E+06 Ru-106 8.343E+07 Xe-135 4.315E+07 Rh-105 1.300E+08 Xe-135m 4.449E+07 Mo-99 2.039E+08 Xe-138 1.715E+08 Noble Metals Tc-99m 1.785E+08 Kr-85 1.071E+06 Ce-141 1.701E+08 Kr-85m 2.230E+07 Ce-143 1.533E+08 Kr-87 4.130E+07 Ce-144 1.338E+08 Noble Gases Kr-88 5.773E+07 Pu-238 5.635E+05 I-131 1.111E+08 Pu-239 3.317E+04 I-132 1.582E+08 Pu-240 4.672E+04 I-133 2.167E+08 Pu-241 1.794E+07 I-134 2.366E+08 Cerium Group Np-239 2.617E+09 Halogens I-135 2.040E+08 La-140 1.892E+08 Cs-134 2.944E+07 La-141 1.705E+08 Cs-136 7.001E+06 La-142 1.629E+08 Cs-137 1.352E+07 Zr-95 1.701E+08 Alkali Metals Rb-86 3.106E+05 Zr-97 1.731E+08 Te-127 1.345E+07 Nd-147 6.966E+07 Te-127m 1.835E+06 Nb-95 1.701E+08 Te-129 3.752E+07 Pr-143 1.518E+08 Te-129m 5.594E+06 Y-90 8.616E+06 Te-131m 1.644E+07 Y-91 1.092E+08 Te-132 1.552E+08 Y-92 1.148E+08 Sb-127 1.353E+07 Y-93 1.389E+08 Tellurium Metals Sb-129 3.813E+07 Cm-242 6.225E+06 Ba-139 1.888E+08 Cm-244 1.868E+06 Ba-140 1.810E+08 Lanthanides Am-241 1.582E+04 Sr-89 7.470E+07 Sr-90 8.124E+06 Sr-91 1.010E+08 Barium, Strontium Sr-92 1.141E+08