ML16343A037

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 11, Table 11.5-1
ML16343A037
Person / Time
Site: Cook  
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A037 (1)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

16.1 Table:

11.5-1 Page:

1 of 1 DESIGN AND MEASURED EQUILIBRIUM REACTOR COOLANT FISSION PRODUCT ACTIVITIES FOR OPERATING PWR'S AND CALCULATED VALUES FOR THE D. C. COOK STATIONS GINNA STATION 1 BEZNAU STATION (1)

COOK STATION DESIGN VALUE 2

µc/cc MEASURED VALUE

µc/cc RATIO MEASURED (Design)

DESIGN VALUE (2)

µc/cc MEASURED VALUE

µc/cc RATIO MEASURED (DESIGN)

DESIGN VALUE (2)

µc/cc Total Activity 216 71 0.33 299 168 0.73 207 Isotopic Activity (Key Isotopes)

I-131 1.53 0.56 0.37 0.96 0.75 0.78 1.7 I-133 2.55 1.7 0.67 1.74 2.0 1.16 2.6 Xe-133 184 45 0.24 200 119 0.60 178 Cs-134 0.19 0.06 0.32 0.22 0.075 0.35 0.13 Cs-137 0.94 0.37 0.40 1.53 0.22 0.15 0.8 1 Based on an assumed 1% defect level.

2 Amendment 20 to original FSAR (Mar, 1972).