Safety Evaluation Supporting Licensee Response to GL 95-07 Re Pressure Locking & Thermal Binding of safety-related power-operated Gate Valves for Plant,Units 1 & 2
ML16342C078
Person / Time
Site: Diablo Canyon  
Issue date: 12/01/1998
From:
NRC (Affiliation Not Assigned)
To:
Shared Package
ML16342A591 List:
References
NUDOCS 9812040003
Download: ML16342C078 (6)


Text

ing% RE0il

~4

~o

++*++

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.c. 205RH)001 F

V B

H FF E

E 7

H AND ERM L BINDIN EL' V

BL AN N

LEAR P 1.0 N

Pressure locking and thermal binding represent potential common-cause failure mechanisms that can render redundant safety systems incapable of performing their safety functions. The identification of susceptible valves and the determination ofwhen the phenomena might occur require a thorough knowledge of components, systems, and plant operations.

Pressure locking occurs in flexible-wedge and double-disk gate valves when fluid becomes pressurized inside the valve bonnet and the actuator is not capable of overcoming the additional thrust requirements resulting from the differential pressure created across both valve disks by the pressurized fluid in the valve bonnet. Thermal binding is generally associated with a wedge gate valve that is closed while the system is hot and then is allowed to cool before an attempt is made to open the valve.

Pressure locking or thermal binding occurs as a result of the valve design characteristics (wedge and valve body configuration, flexibility,and material thermal coefficients) when the valve is subjected to specific pressures and temperatures during various modes of plant operation.

Operating experience indicates that these situations were not always considered in many plants as part of the design basis for valves.

2.0 Part 50 of Title 10 of the Code of Federal Regulations (Appendix A, General Design Criteria 1'nd

4) and plant licensing safety analyses require or commit (or both) that licensees design and test safety-related components and systems to provide adequate assurance that those systems can perform their safety functions. Other individual criteria in Appendix A to 10 CFR Part 50 apply to specific systems.

In accordance with those regulations and licensing commitments, and under the additional provisions of 10 CFR Part 50 (Appendix B, Criterion XVI),licensees are expected to act to ensure that safety-related power-operated gate valves susceptible to pressure locking or thermal binding are capable. of performing their required safety functions.

q812P+QQQ3 98i2pi PDR AogCK 05000275 p

PDR

k

~04 XC f

M I"6I.c'

~

On August 17, 1995, the NRC issued Generic Letter (GL) 95-07, "Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves," to request that licensees take certain actions to ensure those safety-related power-operated gate valves that are, susceptible to pressure locking or thermal binding are capable of performing their safety functions within the current licensing bases of the facility. GL 95-07 requested that each licensee, within 180 days of the date of issuance of the generic letter (1) evaluate the

.operational configurations of safety-related power-operated gate valves in its plant to identify valves that are susceptible to pressure locking or thermal binding, and (2) perform further analyses and take needed corrective actions (or justify longer schedules) to ensure that the susceptible valves, identified in (1) above, are capable of performing their intended safety functions under all modes of plant operation, including test configurations.

In addition, GL 95-07 requested that licensees, within 180 days of the date of issuance of the generic letter, provide to the NRC a summary description of (1) the susceptibility evaluation used to determine that valves are or are not susceptible to pressure locking or thermal binding, (2) the results of the susceptibility evaluation, including a listing of the susceptible valves identified, and (3) the corrective actions, or other dispositioning, for the valves identified as susceptible to pressure locking or thermal binding. The NRC issued GL 95-07 as a "compliance backfit" pursuant to 10 CFR 50.109(a)(4)(i) because modification may be necessary to bring facilities into compliance with the rules of the Commission referenced above, By letter of October 11, 1995, Pacific Gas and Electric Company submitted its 1804ay response to GL 95-07 for Diablo Canyon Nuclear Power Plant, Units 1 and 2. The NRC staff reviewed the licensee's submittal and requested additional information in a letter dated June 5, 1996.

By letter of July 12, 1996, the licensee provided the additional information requested by the staff.

3. ~

WUlAIIOM 3.1 Scope of Licensee's Review GL 95-07 requested that licensees evaluate the operational configurations of safety-related power-operated gate valves in their plants to identify valves that are susceptible to pressure.

locking or thermal binding. The licensee's letters of October 11, 1995, and July 26, 1996, described the scope of valves evaluated in response to GL 95-07. The NRC staff has reviewed the scope of the licensee's susceptibility evaluation performed in response to GL 95-07 and found it complete and acceptable.

The criteria for determining the scope of power-operated valves for GL 95-07 are consistent with the staffs acceptance of the scope of motor-operated valves associated with GL 89-10, "Safety-Related Motor-Operated Valve Testing and Surveillance."

3.2 Corrective Actions GL 95-07 requested that licensees, perform further analyses as appropriate, and take appropriate corrective actions (orjustify longer schedules), to ensure that the susceptible valves identified are capable of performing their intended safety function under all modes of plant operation, including test configurations.

The licensee's submittals discussed proposed

0

~r)

I A

A corrective actions to address potential pressure-locking and thermal-binding problems. The staffs evaluation of the licensee's actions is discussed in the following paragraphs:

a.

The licensee stated that the following valves were modified to eliminate the potential for pressure locking:

1/2-80 00A/B/C 1/2-870 0A/B 1/2-8701 1/2-8702 1/2-8703 1/2-871 6A/B 1/2-8801 A/B 1/2-8802A/B 1/2-8803A/B 1/2-8804A/B 1/2-8982A/B 1/2-9 003A/B 1/2-FCV-95 Pressurizer Power Operated Relief Valve Block Valve Residual Heat Removal (RHR) Pump Suction Reactor Coolant System (RCS) to RHR Isolation RCS to RHR Isolation RHR to Hot Legs RHR Crosstie Charging Injection Safety Injection (Sl) to Hot Legs Charging Injection RHR to Sl/Charging Suction Containment Sump Outlet to RHR RHR to Containment Spray Main Steam to AuxiliaryFeedwater Pump Turbine The staff finds that physical modification to valves susceptible to pressure locking is an appropriate corrective action to ensure operability of the valves and is thus acceptable.

The licensee stated that all flexible and solid wedge gate valves in the scope of GL 95-07 were evaluated for thermal binding. When evaluating whether valves were susceptible to thermal binding, the licensee assumed that thermal binding would not occur below specific temperature thresholds and that torque switch bypass logic to seat flexible wedge gate valves reduces the potential for thermal binding.

The screening criteria used by the licensee appear to provide a reasonable approach to identify those valves that might be susceptible to thermal binding. Until more definitive industry criteria are'eveloped, the staff concludes that the licensee's actions to address thermal binding of gate valves are acceptable.

40 0

On the basis of this evaluation, the NRC staff finds that the licensee has performed appropriate evaluations of the operational configurations of safety-related power-operated gate valves to identify valves at Diablo Canyon Nuclear Power Plant, Units I and 2, that are susceptible to pressure locking or thermal binding.

In addition, the NRC staff finds that the licensee has taken appropriate corrective actions to ensure that these valves are capable of performing their intended safety functions. Therefore, the staff concludes that the licensee has adequately addressed the requested actions discussed in GL 95-07.

Principal Contributor. S. Tingen, NRR Date: