January 19, 1990 Docket Nos.:
50-275 and 50-323 Mr. J.
D. Shiffer, Vice President Nuclear Power Generation c/o Nuclear Power Generation, Licensing Pacific Gas and Electric Company 77 Beale Street, Room 1451 San Francisco, California 94106 DISTRIBUTION C~
EJ d
NRC and LPDRs OGC PDV Reading File WRegan JZwolinski GLapinsky HRood GGalletti JLee ACRS (10)
Dear Mr. Shiffer:
SUBJECT:
SAFETY EVALUATION OF PROCEDURES GENERATION PACKAGE FOR DIABLO CANYON UNITS 1
AND 2 (TAC NOS.
55337 AND 61878)
The purpose of this letter is to forward the NRC staff's safety evaluation report addressing the Procedures Generation Package (PGP) for the Diablo Canyon Nuclear Power Plant, Units 1 and 2, which Pacific Gas and Electric Company submitted by letter dated July 1, 1983.
The NRC staff finds that the program described in the your submittal of July 1, 1983 needs improvement in some respects to ensure that you have the ability to develop and maintain high quality emergency operating procedures.
The staff's findings are discussed in detail in the enclosed safety evaluation (SE).
We request that you revise, as appropriate your PGP to reflect the concerns identified in the SE.
No further submittals to the NRC are required regarding this issue.
This completes the staff's review of this issue.
Please contact us if you have any questions regarding this evaluation.
This completes our efforts on TAC Nos.
55337 and 61878.
Sincerely, original signed by Harry Rood Harry Rood, Senior Project Manager Project Directorate V
Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation cc w/enclosures:
See next page PD5 01
/90 DRSP/PD5 HRood Ol/90 (A)D: PD5 T
mell
/g I/9O OFFICIAL RECORD COPY
(
900i260036 900i i9 PDR ADOCK 05000275 P
4
~p,R REGS~
~o P
o Cl gO
+p*yW Docket Nos.:
50-275 and 50-323 0
UNITEDSTATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 January 19, 1990 Mr. J.
D. Shiffer, Vice President Nuclear Power Generation c/o Nuclear Power Generation, Licensing Pacific Gas and Electric Company 77 Beale Street, Room 1451 San Francisco, California 94106
Dear Mr. Shiffer:
SUBJECT:
SAFETY EVALUATION OF PROCEDURES GENERATION PACKAGE FOR DIABLO
'ANYON UNITS 1
AND 2 (TAC NOS.
55337 AND 61878)
The purpose of this letter is to forward the NRC staff's safety evaluation report addressing the Procedures Generation Package (PGP) for the Diablo Canyon Nuclear Power Plant, Units 1 and 2, which Pacific Gas and Electric Company submitted by letter dated July I, 1983.
The NRC staff finds that the program described in the your submittal of July I, 1983 needs improvement in some respects to ensure that you have the ability to develop and maintain high quality emergency operating procedures.
The staff's findings are discussed in detail in the enclosed safety evaluation (SE).
We request that you revise, as appropriate, your PGP to reflect the concerns identified in the SE.
No further submittals to the NRC are required regarding this issue.
This completes the staff's review of this issue.
Please contact us if you have any questions regarding this evaluation.
This completes our efforts on TAC Nos.
55337 and 61878.
Sincerely, Harry Rood, Senior Project Manager Project Directorate V
Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation cc w/enclosures:
See next page
Mr. J.
D. Shiffer Pacific Gas and Electric Company Diablo Canyon CC:
Richard F. Locke, Esq.
Pacific Gas 5 Electric Company Post Office Box 7442 San Francisco, California 94120 Ms. Sandra A. Silver 660 Granite Creek Road Santa Cruz, California 95065 Mr. Peter H. Kaufman Deputy Attorney General State of California 110 West A Street, Suite 700 San Diego, California 92101 Managing Editor Tt C
~T1
.T il
~1321 Jo nson Avenue P. 0.
Box 112 San Luis Obispo, California 93406 Ms. Nancy Culver 192 Luneta Street San Luis Obispo, California 93401 Regional Administrator, Region V
U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, Ca lifornia 94596 Mr. John Hickman Senior Health Physicist Environmental Radioactive Mgmt. Unit Environmental Management Branch State Department of Health Services 714 P Street, Room 616 Sacramento, California 95814 NRC Resident Inspector Diablo Canyon Nuclear Power Plant c/o U.S. Nuclear Regulatory Commission P. 0.
Box 369 Avila Beach, California 93424 Bruce Norton, Esq.
c/o Richard F. Locke, Esq.
Pacific Gas and Electric Company Post Office Box 7442 San Francisco, California 94120 Dr.
R.
B. Ferguson Sierra Club - Santa Lucia Chapter Rocky Canyon Star Route Creston, California 93432 Chairman San Luis Obispo County Board of Supervisors Room 270 County Government Center San Luis Obispo, California 93408 Michael M. Strumwasser, Esq.
Special Assistant Attorney General State of California Department of Justice 3580 Wilshire Boulevard, Room 800 Los Angeles, California 90010
4